A Review of Power Converter Topology used with PMSG Based Wind Power Generation]

被引:0
作者
Jamil, Majid [1 ]
Gupta, Ravi [1 ]
Singh, Mukhtiar
机构
[1] Jamia Millia Islamia, Dept Elect Engn, New Delhi 110025, India
来源
2012 IEEE FIFTH POWER INDIA CONFERENCE | 2012年
关键词
multi-pole PMSG; multilevel converter; matrix converter; Z-source inverter; PERMANENT-MAGNET GENERATORS; OF-THE-ART; TURBINE; SYSTEMS; OPTIMIZATION; INTEGRATION; INVERTERS; DESIGN; SCHEME;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Wind energy conversion systems are becoming popular in the research areas of renewable energy resources. The commonly used generators with wind energy conversion system (WECS) are Squirrel Cage Induction Generator (SCIG), Doubly Fed Induction Generator (DFIG), Wound Field Synchronous Generator (WFSG) and Permanent Magnet Synchronous Generator (PMSG). Recently PMSG is gaining popularity as it has many advantages over conventional generators. Due to the variable nature of wind, PMSG cannot be directly coupled with the grid. An intermediate power electronic link needs to be provided between the generator and the grid. Many power electronic converter topologies are being used with PMSG. In this paper a review of recent and past grid connected converter topologies, used with PMSG for wind power generation, has been presented.
引用
收藏
页数:6
相关论文
共 69 条
[1]   Design and control of a direct drive wind turbine equipped with multilevel converters [J].
Abbes, Mohamed ;
Belhadj, Jamel ;
Bennani, Afef Ben Abdelghani .
RENEWABLE ENERGY, 2010, 35 (05) :936-945
[2]  
Abbey C., 2004, Canadian Conference on Electrical and Computer Engineering 2004 (IEEE Cat. No.04CH37513), P1059, DOI 10.1109/CCECE.2004.1345301
[3]   Control design and dynamic performance analysis of a wind turbine-induction generator unit [J].
Abdin, ES ;
Xu, W .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2000, 15 (01) :91-96
[4]  
Amirat Y, 2007, J ELECTR SYST, V3, P26
[5]  
[Anonymous], 2006, GLOB WIND EN OUTL 20
[6]  
Baroudi J. A., 2005, International Electric Machines and Drives Conference (IEEE Cat. No.05EX1023C), P458, DOI 10.1109/IEMDC.2005.195763
[7]  
Bose, 2006, POWER ELECT MOTOR DR
[8]  
Bossanyi E., 2000, WIND ENERGY HDB
[9]   DOUBLE-OUTPUT INDUCTION GENERATOR OPERATING AT SUBSYNCHRONOUS AND SUPERSYNCHRONOUS SPEEDS - STEADY-STATE PERFORMANCE OPTIMIZATION AND WIND-ENERGY RECOVERY [J].
CADIRCI, I ;
ERMIS, M .
IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1992, 139 (05) :429-442
[10]   Efficient modulation technique for a four-leg fault-tolerant neutral-point-clamped inverter [J].
Ceballos, Salvador ;
Pou, Josep ;
Zaragoza, Jordi ;
Martin, Jose L. ;
Robles, Eider ;
Gabiola, Igor ;
Ibanez, Pedro .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (03) :1067-1074