Experimental design and the relative sensitivity of BOLD and perfusion fMRI

被引:290
作者
Aguirre, GK
Detre, JA
Zarahn, E
Alsop, DC
机构
[1] Univ Penn, Ctr Cognit Neurosci, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Neurol, Philadelphia, PA 19104 USA
[3] Columbia Univ, Dept Psychiat, New York, NY 10032 USA
[4] Harvard Univ, Sch Med, Boston, MA 02215 USA
[5] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
关键词
D O I
10.1006/nimg.2001.0990
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This paper compares the statistical power of BOLD and arterial spin labeling perfusion fMRI for a variety of experimental designs within and across subjects. Based on theory and simulations, we predict that perfusion data are composed of independent observations in time under the null hypothesis, in contrast to BOLD data, which possess marked autocorrelation. We also present a method (sinc subtraction) of generating perfusion data from its raw source signal that minimizes the presence of oxygen-sensitive signal changes and can be used with any experimental design. Empirically, we demonstrate the absence of autocorrelation in perfusion noise, examine the shape of the hemodynamic response function for BOLD and perfusion, and obtain a measure of signal to noise for each method. This information is then used to generate a model of relative sensitivity of the BOLD and perfusion methods for within-subject experimental designs of varying temporal frequency. It is determined that perfusion fMRI provides superior sensitivity for within-subject experimental designs that concentrate their power at or below similar to0.009 Hz (corresponding to a "blocked" experimental design of 60-s epochs). Additionally, evidence is presented that across-subject hypothesis tests may be more sensitive when conducted using perfusion imaging, despite the better within-subject signal to noise obtained in some cases with BOLD. (C) 2002 Elsevier Science (USA).
引用
收藏
页码:488 / 500
页数:13
相关论文
共 32 条
  • [1] The variability of human, BOLD hemodynamic responses
    Aguirre, GK
    Zarahn, E
    D'Esposito, M
    [J]. NEUROIMAGE, 1998, 8 (04) : 360 - 369
  • [2] Empirical analyses of BOLD fMRI statistics .2. Spatially smoothed data collected under null-hypothesis and experimental conditions
    Aguirre, GK
    Zarahn, E
    DEsposito, M
    [J]. NEUROIMAGE, 1997, 5 (03) : 199 - 212
  • [3] Aguirre GK, 2000, MED RAD DIA IMG, P369
  • [4] A critique of the use of the Kolmogorov-Smirnov (KS) statistic for the analysis of BOLD fMRI data
    Aguirre, GK
    Zarahn, E
    D'Esposito, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (03) : 500 - 505
  • [5] Multisection cerebral blood flow MR imaging with continuous arterial spin labeling
    Alsop, DC
    Detre, JA
    [J]. RADIOLOGY, 1998, 208 (02) : 410 - 416
  • [6] Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow
    Alsop, DC
    Detre, JA
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1996, 16 (06) : 1236 - 1249
  • [7] Magnetic resonance perfusion imaging in acute ischemic stroke using continuous arterial spin labeling
    Chalela, JA
    Alsop, DC
    Gonzalez-Atavales, JB
    Maldjian, JA
    Kasner, SE
    Detre, JA
    [J]. STROKE, 2000, 31 (03) : 680 - 687
  • [8] Detre JA, 2000, MED RAD DIA IMG, P47
  • [9] PROJECTION ANGIOGRAMS OF BLOOD LABELED BY ADIABATIC FAST PASSAGE
    DIXON, WT
    DU, LN
    FAUL, DD
    GADO, M
    ROSSNICK, S
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (03) : 454 - 462
  • [10] Duong TQ, 2000, MAGN RESON MED, V44, P231, DOI 10.1002/1522-2594(200008)44:2<231::AID-MRM10>3.0.CO