HTS scanning SQUID microscope cooled by a closed-cycle refrigerator

被引:7
作者
Fleet, EF [1 ]
Chatraphorn, S
Wellstood, FC
Green, SM
Knauss, LA
机构
[1] Univ Maryland, Dept Phys & Astron, Ctr Superconduct Res, College Pk, MD 20742 USA
[2] Neocera Inc, Beltsville, MD 20705 USA
[3] Vivid Technol Inc, San Diego, CA 92126 USA
关键词
D O I
10.1109/77.783833
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have developed a scanning SQUID microscope which uses a commercially available closed-cycle refrigerator to cool a YBa2Cu3O7 bi-crystal de SQUID to about 77 K. The system allows magnetic imaging of samples which are at room temperature and pressure with spatial resolutions of 50 mu m or better. It is more compact and requires less maintenance than a more conventional liquid-nitrogen cooled system, while delivering equal sensitivity. In order to reduce the SQUID-sample separation while maintaining vacuum thermal isolation of the SQUID, the sensor is separated from the sample by a 25 mu m thick, optically transparent window. The noise spectrum of our SQUID shows a 1/f spectrum below 500 Hz with 72 pT/root Hz field sensitivity at 10 Hz, and a white noise level of 20 pT/root Hz.
引用
收藏
页码:3704 / 3707
页数:4
相关论文
共 50 条
[31]   HTS scanning SQUID microscope with high spatial resolution for room temperature samples [J].
Gudoshnikov, SA ;
Liubimov, BY ;
Deryuzhkina, YV ;
Matveets, LV ;
Snigirev, OV ;
Kalabukhov, AS ;
Ranchinski, ML ;
Schmidl, F ;
Seidel, P .
PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2002, 372 :166-169
[32]   CLOSED-CYCLE TURBOMACHINERY [J].
STERNLIC.B .
MECHANICAL ENGINEERING, 1966, 88 (05) :149-+
[33]   Cryogen-free operation of programmable Josephson voltage standard with a closed-cycle refrigerator [J].
Chong, Yonuk ;
Kim, Mun-Seog ;
Kim, Wan-Seop ;
Kim, Kyu-Tae .
2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, :586-587
[34]   TRIGGER UNIT FOR SYSTEMS THAT USE DIODE-LASERS MOUNTED ON A CLOSED-CYCLE REFRIGERATOR [J].
RODRIGUEZ, M ;
ALVAREZ, RA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (08) :4014-4015
[35]   Low-Noise Closed-Cycle Helium Recondensing for SQUID Biomagnetic Measurement System [J].
Adachi, Y. ;
Oyama, D. ;
Kawai, J. ;
Uehara, G. ;
Fujihira, J. ;
Fujihira, H. .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (05)
[36]   Experimental investigation on a closed-cycle single-stage turbo-refrigerator for deep freezing [J].
Song, Shujian ;
Chen, Shuangtao ;
Zhou, Xiaocong ;
Zhu, Yihang ;
Zhang, Xihan ;
Chen, Liang ;
Hou, Yu .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 155 :247-257
[37]   FREQUENCY JITTER FROM MECHANICAL VIBRATIONS IN A DIODE-LASER MOUNTED ON A CLOSED-CYCLE REFRIGERATOR [J].
MELANDRONE, G ;
CAPPELLANI, F ;
RESTELLI, G .
APPLIED SPECTROSCOPY, 1985, 39 (01) :63-68
[38]   CONSIDERATIONS FOR THE CLOSED-CYCLE MILL [J].
RICKETTS, JD .
TAPPI JOURNAL, 1994, 77 (11) :43-49
[39]   Construction and calibration of a 12 T pulsed magnet integrated with a 4 K closed-cycle refrigerator [J].
Murthy, O. V. S. N. ;
Venkataraman, V. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (11)
[40]   Analytical and experimental study on operating characteristics of a closed-cycle turbo-refrigerator for deep freezing [J].
Song, Shujian ;
Zhang, Ze ;
Zhou, Xiaocong ;
Ju, Qian ;
Chen, Liang ;
Chen, Shuangtao ;
Hou, Yu .
APPLIED THERMAL ENGINEERING, 2024, 250