Corrosion failure analysis of galvanized steel pipes in a water irrigation system

被引:20
作者
Della Rovere, C. A. [1 ]
Silva, R. [1 ]
Moretti, C. [2 ]
Kuri, S. E. [1 ]
机构
[1] Univ Fed Sao Carlos, Corros Lab, Dept Mat Engn, LC DEMa UFSCar, BR-13565905 Sao Carlos, SP, Brazil
[2] Univ Fed Sao Carlos, Ctr Characterizat & Dev Mat, Dept Mat Engn, Lab Electron Microscopy,CCDM DEMa UFSCar, BR-13565905 Sao Carlos, SP, Brazil
关键词
Galvanized steel pipes; Irrigation system; Creek water; Acid corrosion; Impingement; CONCRETE;
D O I
10.1016/j.engfailanal.2013.06.024
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The premature failure of a water irrigation system made of galvanized steel pipes installed in the orange orchards of a citrus farm located in the interior of the state of Sao Paulo, Brazil, was investigated by onsite visual inspection, microstructural characterization of the Zn coatings based on SEM/EDS analysis, and chemical and physical analysis of the water used in the system. The irrigation water comes from a creek that runs through the farm, and the first pipe leakages were detected after the system had been in operation for only 2 years. The findings of this investigation indicate that the failure of the pipes before their expected service lifetime was caused by acid corrosion, which rapidly attacked the Zn coating of the inner walls of the pipes, exposing the entire steel surface in the first months of use. The deterioration of the pipes was intensified by the mechanical wear resulting from a substantial amount of suspended solids in the flowing water. In addition, the SEM/EDS analysis of the Zn coating suggested that some points of the galvanized pipes exhibited manufacturing defects, further impairing the corrosion performance of these pipes. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:381 / 386
页数:6
相关论文
共 15 条
[1]  
AGA American Galvanizers Association, WATER
[2]  
[Anonymous], 1987, METALS HDB, V13
[3]  
[Anonymous], 2012, HDB CORROSION ENG
[4]  
ARAGAO MA, 2003, ACTA LIMNOL BRAS, V15, P15
[5]   Erosion corrosion of pump impeller of cyclic cooling water system [J].
Ariely, S ;
Khentov, A .
ENGINEERING FAILURE ANALYSIS, 2006, 13 (06) :925-932
[6]   Corrosion behaviour in concrete of three differently galvanized steel bars [J].
Bellezze, T ;
Malavolta, A ;
Quaranta, A ;
Ruffini, N ;
Roventi, G .
CEMENT & CONCRETE COMPOSITES, 2006, 28 (03) :246-255
[7]   Control of the growth of zinc-iron phases in the hot-dip galvanizing process [J].
Culcasi, JD ;
Seré, PR ;
Elsner, CI ;
Di Sarli, AR .
SURFACE & COATINGS TECHNOLOGY, 1999, 122 (01) :21-23
[8]  
Fontana M.G., 1985, Corrosion Engineering, V3rd
[9]   Boiler feedwater pipe failure by flow-assisted chelant corrosion [J].
Hales, C ;
Stevens, KJ ;
Daniel, PL ;
Zamanzadeh, M ;
Owens, AD .
ENGINEERING FAILURE ANALYSIS, 2002, 9 (02) :235-243
[10]  
Jones D.A., 1995, Principles and prevention of corrosion, V2nd