Simulating the effects of fuel type and geometry on post-flashover fire temperatures

被引:13
作者
Yii, EH
Buchanan, AH
Fleischmann, CM
机构
[1] Univ Canterbury, Christchurch 1, New Zealand
[2] Arup Fire, Sydney, NSW, Australia
关键词
post-flashover fires; single zone fire model; wood; pool fire; time-temperature history; parametric fires;
D O I
10.1016/j.firesaf.2005.09.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper discusses the effect of fuel type and geometry on predicted compartment temperatures derived from computer modelling of post-flashover compartment fires. Many previous studies have investigated post-flashover fires with either wood crib or liquid pool fuels, but very few analytical or experimental studies have considered realistic wood-based fuels with different ratios of surface area to Volume, combined with plastic-based fuels. A simple single zone fire model was used to calculate the temperatures in post-flashover compartment fires. The program includes a catalogue of furniture items, each with fuel mass loss rate evaluated on the basis of a constant regression rate on all exposed surfaces. The program also includes a pool-burning model and considers wood fuels and thermoplastic fuels burning together inside a compartment. Use of the model shows that the total fuels load alone is not sufficient to characterise a post-flashover fire. The fire temperature is highly dependent on the fuel type and geometry. For given ventilation and total fuel load, the resulting temperature depends greatly on the average thickness of the wood fuels and the presence of thermoplastic fuels. The ratio of the available fuel surface area to the ventilation opening is particularly important. Several fire scenarios involving different fuel types and characteristics are simulated and compared with Eurocode parametric fires. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:62 / 75
页数:14
相关论文
共 40 条
[1]  
AKHIMIE N., 2017, Journal of Civil & Environmental Engineering, V4, P63
[2]  
[Anonymous], 1979, 991 NBS
[3]  
*ASTM, 1988, E11988 ASTM
[4]  
ATREYA A, 1983, NBSGCR83449
[5]   A CLOSED-FORM APPROXIMATION FOR POST-FLASHOVER COMPARTMENT FIRE TEMPERATURES [J].
BABRAUSKAS, V .
FIRE SAFETY JOURNAL, 1981, 4 (01) :63-73
[6]   THERMOPLASTIC POOL COMPARTMENT FIRES [J].
BABRAUSKAS, V ;
WICKSTROM, UG .
COMBUSTION AND FLAME, 1979, 34 (02) :195-202
[7]   POST-FLASHOVER COMPARTMENT FIRES - BASIS OF A THEORETICAL-MODEL [J].
BABRAUSKAS, V ;
WILLIAMSON, RB .
FIRE AND MATERIALS, 1978, 2 (02) :39-53
[8]  
Babrauskas V., 1992, Heat release in fires, P207
[9]  
*BIA, 1992, NZ BUILD COD APPR DO
[10]   RADIATIVE ENERGY BLOCKAGE IN LARGE POOL FIRES [J].
BROSMER, MA ;
TIEN, CL .
COMBUSTION SCIENCE AND TECHNOLOGY, 1987, 51 (1-3) :21-37