Multiple receivers in a high-resolution near-infrared heterodyne spectrometer

被引:11
作者
Kurtz, Joe [1 ]
O'Byrne, Sean [1 ]
机构
[1] Univ New South Wales, Sch Engn & Informat Technol, Canberra, ACT 2611, Australia
关键词
SPECTROSCOPY; RADIOMETER;
D O I
10.1364/OE.24.023838
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The paper describes a modification of a high-resolution heterodyne NIR spectrometer described by Rodin, et al. in Opt. Express 22, 13825 (2014), wherein the noise amplitude of the heterodyne signal squared was proportional to the power of the incoherent radiation source (the sun). The addition of a second receiver collecting radiation from the sun into a second single-mode fiber created up to a factor of two increase in detected source power spectrum. The ability to add uncorrelated heterodyne IF signals as Gaussian noise (variance) provides the means by which multiple heterodyne receivers of signal from an incoherent source can increase the detected source power by the same multiple, thus avoiding the limit imposed by the antenna theorem for a single receiver (A. E. Siegman, Appl. Opt. 5, 1588 (1966)). (C) 2016 Optical Society of America
引用
收藏
页码:23838 / 23848
页数:11
相关论文
共 12 条
[11]  
Weidmann D., 2015, COMMUNICATION
[12]   Miniaturized laser heterodyne radiometer for measurements of CO2 in the atmospheric column [J].
Wilson, E. L. ;
McLinden, M. L. ;
Miller, J. H. ;
Allan, G. R. ;
Ott, L. E. ;
Melroy, H. R. ;
Clarke, G. B. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2014, 114 (03) :385-393