Modified carbon paste electrodes for Cu(II) determination

被引:18
作者
Ghaedi, Mehrorang [1 ]
Naderi, Sakineh [1 ]
Montazerozohori, Morteza [1 ]
Sahraei, Reza [2 ]
Daneshfar, Ali [2 ]
Taghavimoghadam, Narges [1 ]
机构
[1] Univ Yasuj, Dept Chem, Yasuj 7591874831, Iran
[2] Ilam Univ, Dept Chem, Ilam, Iran
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2012年 / 32卷 / 08期
关键词
Carbon paste electrode; Copper ion; Palladium nanoparticle; Cadmium sulfide nanoparticles; Potentiometric sensors; 2,2 '-(1E,1 ' E)-1,1 '-(2,2 '-azanediylbis(ethane-2,1-diyl)bis(azan-1-yl-1-ylidene))bis(ethan-1-yl-1-ylidene)diphenol (ADEZEDP); COBALT(III) SCHIFF-BASE; MEMBRANE ELECTRODES; COPPER-ION; SELECTIVE ELECTRODE; SENSORS; PORPHYRINS; CHEMISTRY; CARRIER;
D O I
10.1016/j.msec.2012.06.014
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
A new Cu2+ carbon paste electrode (CPE) using 2,2'-(1E,1'E)-1,1'-(2,2'-azanediylbis (ethane-2,1-diyl) bis(azan-1-yl-1-ylidene))bis(ethan-1-yl-1-ylidene)diphenol (ADEZEDP) has been prepared. The influence of variables including sodium tetraphenylborate (NaTPB). ionophore, and amount of multiwalled carbon nanotubes (MWCNT). CdO nanowires, CdS nanoparticles and palladium nanoparticles loaded on ADEZEDP and Nujol on the electrodes response were studied and optimized. At optimum values of all variables, for each nanomaterial the electrode response was linear in concentration range of 1.0x10(-8) to 1.0x10(-1) mol L-1 for ADEZEDP with Nernstian slope. The good performance of electrode viz. Wide applicable pH range (2.0-5.0), fast response time (approximate to 6 s). and adequate life time (3 months) indicate the utility of the proposed electrodes for evaluation of Cu2+ ion content in various situations. Finally, these electrodes have been successfully applied for the determination of Cu2+ ions content in various real samples. The selectivity of proposed electrode was evaluated by separation solution method and fixed interference method. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:2274 / 2279
页数:6
相关论文
共 50 条
[31]   Voltammetric Determination of Pb(II) Ions at a Modified Kaolinite-Carbon Paste Electrode [J].
Akanji, Seyi P. ;
Arotiba, Omotayo A. ;
Nkosi, Duduzile .
ELECTROCATALYSIS, 2019, 10 (06) :643-652
[32]   Voltammetric Determination of Pb(II) Ions at a Modified Kaolinite-Carbon Paste Electrode [J].
Seyi P. Akanji ;
Omotayo A. Arotiba ;
Duduzile Nkosi .
Electrocatalysis, 2019, 10 :643-652
[33]   Cyclam modified carbon paste electrode as a potentiometric sensor for determination of cobalt(II) ions [J].
Pouretedal, HR ;
Keshavarz, MH .
CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2005, 21 (01) :28-31
[34]   Response Surface Optimization of MWCNT modified Carbon Paste Electrode for Zn(II) Determination [J].
Isaac, Rimal ;
Praseetha, P. K. .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (09) :7303-7319
[35]   Copper(II) determination by using carbon paste electrode modified with molecularly imprinted polymer [J].
Wang Zhihua ;
Liu Xiaole ;
Yang Jianming ;
Qin Yaxin ;
Lu Xiaoquan .
ELECTROCHIMICA ACTA, 2011, 58 :750-756
[36]   Voltammetric determination of lead (II) ions at carbon paste electrode modified with banana tissue [J].
Institute of Chemistry, University of the Philippines, Los Baños, Philippines .
J. Appl. Sci., 2007, 9 (1286-1292) :1286-1292
[37]   Determination of pethidine hydrochloride using potentiometric coated graphite and carbon paste electrodes [J].
Abu-Shawish, Hazem M. ;
Dalou, Ayoub A. ;
Abu Ghalwa, Nasser ;
Khraish, Ghada I. ;
Hammad, Jehad ;
Basheer, Abdel-Hakem .
DRUG TESTING AND ANALYSIS, 2013, 5 (04) :213-221
[38]   ELECTROCHEMICAL CHARACTERIZATION OF CARBON PASTE ELECTRODES MODIFIED WITH NATURAL ZEOLITE [J].
Zacahua Tlacuatl, G. ;
Castro Arellano, J. J. ;
Manzo-Robledo, A. .
CHEMICAL ENGINEERING COMMUNICATIONS, 2009, 196 (10) :1178-1188
[39]   Multiwall Carbon Nanotubes Modified Carbon Paste Electrode for Determination of Copper(II) by Potentiometric and Impedimetric Methods [J].
Mazloum-Ardakani, M. ;
Mandegari, A. A. ;
Masoum, S. ;
Naeimi, H. .
JOURNAL OF NANOSTRUCTURES, 2012, 2 (03) :333-343
[40]   Stripping voltammetric determination of silymarin in formulations and human blood utilizing bare and modified carbon paste electrodes [J].
El-Desoky, Hanaa S. ;
Ghoneim, Mohamed M. .
TALANTA, 2011, 84 (01) :223-234