3D ultrasound centerline tracking of abdominal vessels for endovascular navigation

被引:16
作者
Zhang, L. [1 ,2 ]
Parrini, S. [1 ]
Freschi, C. [1 ]
Ferrari, V. [1 ]
Condino, S. [1 ]
Ferrari, M. [1 ,3 ]
Caramella, D. [3 ]
机构
[1] Univ Pisa, EndoCAS Ctr, Pisa, Italy
[2] Capital Med Univ, Sch Biomed Engn, Beijing, Peoples R China
[3] Univ Pisa, Dipartimento Integrato Interistituz, Pisa, Italy
关键词
3D ultrasound; Centerline extraction; Centerline tracking; Image guided surgery; Endovascular; SEGMENTATION; SURGERY; SYSTEM; PLATFORM;
D O I
10.1007/s11548-013-0917-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Vessel lumen centerline extraction is important for intraoperative tracking of abdominal vessels and guidance of endovascular instruments. Three-dimensional ultrasound has gained increasing acceptance as a safe and convenient surgical image guidance modality. We aimed to optimize vascular centerline detection and tracking in 3D ultrasound. To overcome the intrinsic limitation of low ultrasound image quality, an active contour method (snake) was used to track changes in vessel geometry. We tested two variants of a classic snake using the image gradient and gradient vector field (GVF) as external forces. We validated these methods in liver ultrasound images of 10 healthy volunteers, acquired at three breath-holding instances during the exhalation phase. We calculated the distances between the vessel centerlines as detected by algorithms and a gold standard consisting of manual annotations performed by an expert. Both methods (GVF and image gradient) can accurately estimate the actual centerlines with average Euclidean distances of 0.77 and 1.24 mm for GVF and gradient, respectively. Both methods can automatically follow vessel morphology and position changes. The proposed approach is feasible for liver vessel centerline extraction from 3D ultrasound images. The algorithm can follow the movement of the vessels during respiration; further improvements of hardware components are needed for a real-time implementation.
引用
收藏
页码:127 / 135
页数:9
相关论文
共 37 条
[21]   EndoCAS navigator platform: a common platform for computer and robotic assistance in minimally invasive surgery [J].
Megali, Giuseppe ;
Ferrari, Vincenzo ;
Freschi, Cinzia ;
Morabito, Bruno ;
Turini, Giuseppe ;
Troia, Elena ;
Cappelli, Carla ;
Pietrabissa, Andrea ;
Tonet, Oliver ;
Cuschieri, Alfred ;
Dario, Paolo ;
Mosca, Franco .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2008, 4 (03) :242-251
[22]  
Miloro P, 2012, P IEEE RAS-EMBS INT, P731, DOI 10.1109/BioRob.2012.6290758
[23]  
Nam WH, 2010, ROBUST REGISTRATION, DOI [10.1109/ISBI.2010.5490210, DOI 10.1109/ISBI.2010.5490210]
[24]  
Navigator EP, EP NAV
[25]   Surgical Engineering in Cranio-Maxillofacial Surgery: A Literature Review [J].
Olszewski, Raphael .
JOURNAL OF HEALTHCARE ENGINEERING, 2012, 3 (01) :53-86
[26]   Image-guidance for surgical procedures [J].
Peters, Terry M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (14) :R505-R540
[27]  
Pujol S, 2004, STUD HEALTH TECHNOL, V98, P310
[28]   Preliminary results of nonfluoroscopy-based 3D navigation for neurointerventional procedures [J].
Pujol, Sonia ;
Frerichs, Kai ;
Norbash, Alexander ;
Kikinis, Ron ;
Westin, Carl-Fredrik .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 18 (02) :289-298
[29]   Magnetic propulsion and ultrasound tracking of endovascular devices [J].
S. Tognarelli ;
V. Castelli ;
G. Ciuti ;
C. Di Natali ;
E. Sinibaldi ;
P. Dario ;
A. Menciassi .
Journal of Robotic Surgery, 2012, 6 (1) :5-12
[30]   Three-dimensional ultrasound of carotid atherosclerosis: Semiautomated segmentation using a level set-based method [J].
Ukwatta, E. ;
Awad, J. ;
Ward, A. D. ;
Buchanan, D. ;
Samarabandu, J. ;
Parraga, G. ;
Fenster, A. .
MEDICAL PHYSICS, 2011, 38 (05) :2479-2493