3D ultrasound centerline tracking of abdominal vessels for endovascular navigation

被引:16
作者
Zhang, L. [1 ,2 ]
Parrini, S. [1 ]
Freschi, C. [1 ]
Ferrari, V. [1 ]
Condino, S. [1 ]
Ferrari, M. [1 ,3 ]
Caramella, D. [3 ]
机构
[1] Univ Pisa, EndoCAS Ctr, Pisa, Italy
[2] Capital Med Univ, Sch Biomed Engn, Beijing, Peoples R China
[3] Univ Pisa, Dipartimento Integrato Interistituz, Pisa, Italy
关键词
3D ultrasound; Centerline extraction; Centerline tracking; Image guided surgery; Endovascular; SEGMENTATION; SURGERY; SYSTEM; PLATFORM;
D O I
10.1007/s11548-013-0917-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Vessel lumen centerline extraction is important for intraoperative tracking of abdominal vessels and guidance of endovascular instruments. Three-dimensional ultrasound has gained increasing acceptance as a safe and convenient surgical image guidance modality. We aimed to optimize vascular centerline detection and tracking in 3D ultrasound. To overcome the intrinsic limitation of low ultrasound image quality, an active contour method (snake) was used to track changes in vessel geometry. We tested two variants of a classic snake using the image gradient and gradient vector field (GVF) as external forces. We validated these methods in liver ultrasound images of 10 healthy volunteers, acquired at three breath-holding instances during the exhalation phase. We calculated the distances between the vessel centerlines as detected by algorithms and a gold standard consisting of manual annotations performed by an expert. Both methods (GVF and image gradient) can accurately estimate the actual centerlines with average Euclidean distances of 0.77 and 1.24 mm for GVF and gradient, respectively. Both methods can automatically follow vessel morphology and position changes. The proposed approach is feasible for liver vessel centerline extraction from 3D ultrasound images. The algorithm can follow the movement of the vessels during respiration; further improvements of hardware components are needed for a real-time implementation.
引用
收藏
页码:127 / 135
页数:9
相关论文
共 37 条
  • [1] Real-time respiratory motion tracking: Roadmap correction for hepatic artery catheterizations
    Atasoy, Selen
    Groher, Martin
    Zikic, Darko
    Glocker, Ben
    Waggershauser, Tobias
    Pfister, Marcus
    Navab, Nassir
    [J]. MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2, 2008, 6918
  • [2] Non-invasive quantification of diaphragm kinetics using m-mode sonography
    Ayoub, J
    Cohendy, R
    Dauzat, M
    Targhetta, R
    DeLaCoussaye, JE
    Bourgeois, JM
    Ramonatxo, M
    Prefaut, C
    Pourcelot, L
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1997, 44 (07): : 739 - 744
  • [3] CARTO, BIOS WEBST
  • [4] Estimating 3D lumen centerlines of carotid arteries in free-hand acquisition ultrasound
    Carvalho, Diego D. B.
    Klein, Stefan
    Akkus, Zeynettin
    ten Kate, Gerrit L.
    Schinkel, Arend F. L.
    Bosch, Johan G.
    van der Lugt, Aad
    Niessen, Wiro J.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (02) : 207 - 215
  • [5] Castor Mei L, 2008, Infect Dis Obstet Gynecol, V2008, P727505, DOI 10.1155/2008/727505
  • [6] Electromagnetic navigation platform for endovascular surgery: how to develop sensorized catheters and guidewires
    Condino, S.
    Ferrari, V.
    Freschi, C.
    Alberti, A.
    Berchiolli, R.
    Mosca, F.
    Ferrari, M.
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2012, 8 (03) : 300 - 310
  • [7] Overview of the vascular interventional robot
    Da, Liu
    Zhang, Dapeng
    Wang, Tianmiao
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2008, 4 (04) : 289 - 294
  • [8] A Framework for Intraoperative Update of 3D Deformable Models in Liver Surgery
    Dagon, Benoit
    Baur, Charles
    Bettschart, Vincent
    [J]. 2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 3235 - +
  • [9] Navigation knee replacement
    Dattani, Rupen
    Patnaik, Surendra
    Kantak, Avadhoot
    Tselentakis, Georgis
    [J]. INTERNATIONAL ORTHOPAEDICS, 2009, 33 (01) : 7 - 10
  • [10] Dimitrov K, 2007, INT WORKSH INT DATA, P639