Estimation of Multipath Transmission Parameters for Quantitative Ultrasound Measurements of Bone

被引:12
|
作者
Dencks, Stefanie [1 ]
Schmitz, Georg [1 ]
机构
[1] Ruhr Univ Bochum, Inst Med Engn, Bochum, Germany
关键词
BAYESIAN PROBABILITY-THEORY; BOVINE CANCELLOUS BONE; MODEL-BASED ESTIMATION; TRABECULAR BONE; PROXIMAL FEMUR; IN-VITRO; SLOW WAVES; NUMERICAL-SIMULATION; MATCHING PURSUITS; FREQUENCY RANGE;
D O I
10.1109/TUFFC.2013.2773
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
When applying quantitative ultrasound (QUS) measurements to bone for predicting osteoporotic fracture risk, the multipath transmission of sound waves frequently occurs. In the last 10 years, the interest in separating multipath QUS signals for their analysis awoke, and led to the introduction of several approaches. Here, we compare the performances of the two fastest algorithms proposed for QUS measurements of bone: the modified least-squares Prony method (MLSP), and the space alternating generalized expectation maximization algorithm (SAGE) applied in the frequency domain. In both approaches, the parameters of the transfer functions of the sound propagation paths are estimated. To provide an objective measure, we also analytically derive the Cramer-Rao lower bound of variances for any estimator and arbitrary transmit signals. In comparison with results of Monte Carlo simulations, this measure is used to evaluate both approaches regarding their accuracy and precision. Additionally, with simulations using typical QUS measurement settings, we illustrate the limitations of separating two superimposed waves for varying parameters with focus on their temporal separation. It is shown that for good SNRs around 100 dB, MLSP yields better results when two waves are very close. Additionally, the parameters of the smaller wave are more reliably estimated. If the SNR decreases, the parameter estimation with MLSP becomes biased and inefficient. Then, the robustness to noise of the SAGE clearly prevails. Because a clear influence of the interrelation between the wavelength of the ultrasound signals and their temporal separation is observable on the results, these findings can be transferred to QUS measurements at other sites. The choice of the suitable algorithm thus depends on the measurement conditions.
引用
收藏
页码:1884 / 1895
页数:12
相关论文
共 50 条
  • [1] Separation of Multipath Transmission Signals for Quantitative Ultrasound Measurement at Bone - a Comparison Study
    Dencks, Stefanie
    Schmitz, Georg
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 1019 - 1022
  • [2] Relationships of trabecular bone structure with quantitative ultrasound parameters:: In vitro study on human proximal femur using transmission and backscatter measurements
    Padilla, F.
    Jenson, F.
    Bousson, V.
    Peyrin, F.
    Laugier, P.
    BONE, 2008, 42 (06) : 1193 - 1202
  • [3] Quantitative ultrasound measurements of bone strength in myelomeningocele
    Pedrotti, L
    Tuvo, G
    Bertani, B
    Mora, R
    Pezzotta, S
    Valci, L
    Piazza, F
    Dalla Toffola, E
    Chiari, G
    Quaglini, S
    OSTEOPOROSIS INTERNATIONAL, 2002, 13 : S29 - S29
  • [4] Bone status in infants measured by axial transmission quantitative ultrasound (QUS): are all measurements equal?
    Koo, Winston
    BONE, 2008, 43 : S84 - S84
  • [5] Estimation of transmission line parameters from measurements
    Indulkar, C. S.
    Ramalingam, K.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2008, 30 (05) : 337 - 342
  • [6] Bone marrow influences quantitative ultrasound measurements in human cancellous bone
    Nicholson, PHF
    Bouxsein, ML
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (03): : 369 - 375
  • [7] Associations between parameters of ultrasound transmission and structural parameters of cortical bone
    Barkmann, R
    Glüer, CC
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1649 - 1652
  • [8] Estimation of Transmission Line Parameters Using PMU Measurements
    Asprou, Markos
    Kyriakides, Elias
    2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,
  • [9] Do axial transmission ultrasound measurements of bone differ temperature?
    Khan, AS
    Brooke-Wavell, K
    Havenith, G
    JOURNAL OF BONE AND MINERAL RESEARCH, 2005, 20 (09) : S121 - S121
  • [10] Performance of quantitative ultrasound measurements of bone for monitoring raloxifene therapy
    Paggiosi, M. A.
    Clowes, J. A.
    Finigan, J.
    Peel, N. F. A.
    Eastell, R.
    CALCIFIED TISSUE INTERNATIONAL, 2008, 82 : S240 - S241