Inter-rater reliability and validity of automated impedance manometry analysis and fluoroscopy in dysphagic patients after head and neck cancer radiotherapy

被引:21
|
作者
Szczesniak, M. M. [1 ,2 ]
Maclean, J. [3 ]
Zhang, T. [1 ,2 ]
Liu, R. [1 ,4 ]
Cock, C. [5 ]
Rommel, N. [6 ]
Omari, T. I. [5 ]
Cook, I. J. [1 ,2 ]
机构
[1] St George Hosp, Dept Gastroenterol & Hepatol, Sydney, NSW, Australia
[2] Univ New S Wales, St George Clin Sch, Sydney, NSW, Australia
[3] St George Hosp, Speech Pathol Dept, Sydney, NSW, Australia
[4] Lanzhou Univ, Dept Geriatr Med, Hosp 1, Lanzhou, Gansu, Peoples R China
[5] Flinders Univ S Australia, Sch Med, Human Physiol Med Sci & Technol & Gastroenterol, Adelaide, SA 5001, Australia
[6] Univ Leuven, ExpORL Translat Res Ctr Gastrointestinal Dis, Neurosci, Leuven, Belgium
来源
NEUROGASTROENTEROLOGY AND MOTILITY | 2015年 / 27卷 / 08期
基金
澳大利亚国家健康与医学研究理事会;
关键词
dysphagia; impedance; manometry; pharynx; reliability; videofluoroscopy; ASPIRATION PNEUMONIA; SWALLOW; PREDICTORS;
D O I
10.1111/nmo.12610
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background Pharyngeal automated impedance manometry (AIM) analysis is a novel non-radiological method to analyze swallowing function based on impedance-pressure recordings. In dysphagic head and neck cancer patients, we evaluated the reliability and validity of the AIM-derived swallow risk index (SRI) and a novel measure of postswallow residue (iZn/Z) by comparing it against videofluoroscopy as the gold standard. Methods Three blinded experts classified 88 videofluoroscopic swallows from 16 patients for aspiration and degree of postswallow residue. Pressure-impedance recordings of the patient and age-matched control swallows were analyzed using AIM by three observers who derived the SRI and iZn/Z. Intra-class correlation coefficients (ICC) were calculated for videofluoroscopic and AIM measures. Patient pressure/impedance measurements were compared with videofluoroscopy scores and control subjects to determine validity for detecting clinically relevant swallowing dysfunction. Key Results Agreement among observers assessing presence of penetration and aspiration was modest (ICC 0.57) for videofluoroscopy and good (ICC 0.71, 0.82) for AIM-derived SRI and iZn/Z. When compared with age-matched controls, the SRI was higher in patients with aspiration (mean diff. 28.6, 95% CI [55.85, 1.355], p < 0.05). The iZn/Z had moderate positive correlation with bolus residue on fluoroscopy (BRS score) ((rs)(86) = 0.4120, p < 0.0001) and was increased in both patients with aspiration (Delta 244 [419.7, 69.52; p < 0.05]) and penetration (Delta 240 [394.3, 85.77]; p < 0.05) compared to controls. Conclusions & Inferences AIM-based measures of swallowing function have better inter-rater reliability than comparable fluoroscopically derived measures. These measures are easily determined and objective markers of clinically relevant features of disordered swallowing following radiotherapy.
引用
收藏
页码:1183 / 1189
页数:7
相关论文
共 50 条
  • [1] Intra-Rater and Inter-Rater Reproducibility of Pharyngeal Automated Impedance Manometry vs. Videofluoroscopy
    Omari, Taher
    Dejaeger, Eddy W.
    Goeleven, Ann
    Cornelissen, Liesbeth
    Vos, Rita
    Wauters, Lucas I.
    Slootmaekers, Sara
    Tack, Jan F.
    Papathanasopoulos, Athanasios A.
    Rommel, Nathalie
    GASTROENTEROLOGY, 2011, 140 (05) : S298 - S298
  • [2] Inter-rater reliability of McKenzie assessment in patients with neck pain
    Dionne, Carol P.
    Bybee, Ronald F.
    Tomaka, Joe
    PHYSIOTHERAPY, 2006, 92 (02) : 75 - 82
  • [3] Validation and Inter-rater Reliability of the Modified Videofluoroscopic Dysphagia Scale (mVDS) in Dysphagic Patients with Multiple Etiologies
    Chang, Min Cheol
    Lee, Changbae
    Park, Donghwi
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (13)
  • [4] Inter-rater reliability and validity of the Action Research arm test in stroke patients
    Hsieh, CL
    Hsueh, IP
    Chiang, FM
    Lin, PH
    AGE AND AGEING, 1998, 27 (02) : 107 - 114
  • [5] Inter-rater reliability of select physical examination procedures in patients with neck pain
    Hanney, William J.
    George, Steven Z.
    Kolber, Morey J.
    Young, Ian
    Salamh, Paul A.
    Cleland, Joshua A.
    PHYSIOTHERAPY THEORY AND PRACTICE, 2014, 30 (05) : 345 - 352
  • [6] Intra- and inter-rater reliability of neutral head position and target head position tests in patients with and without neck pain
    Alahmari, Khalid
    Reddy, Ravi Shankar
    Silvian, Paul
    Ahmad, Irshad
    Nagaraj, Venkat
    Mahtab, Mohammad
    BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2017, 21 (04) : 259 - 267
  • [7] Analysis of Inter-rater Reliability of the Mammography Assessment after Image Processing
    Turhan, Kemal
    Kurt, Burcin
    Kul, Sibel
    Yazagan, Asli
    BIOINFORMATICS AND BIOMEDICAL ENGINEERING (IWBBIO 2015), PT II, 2015, 9044 : 77 - 84
  • [8] Inter-rater reliability, discriminatory and predictive validity of neck movement control tests in office workers with headache and/or neck pain
    Ernst, Markus J.
    Klaus, Sandro
    Ludtke, Kerstin
    Gallina, Alessio
    Falla, Deborah
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2022, 62
  • [9] Inter-rater reliability and concurrent validity of walking speed measurement after traumatic brain injury
    van Loo, M
    Moseley, AM
    Bosman, JM
    de Bie, RA
    Hassett, L
    CLINICAL REHABILITATION, 2003, 17 (07) : 775 - 779
  • [10] Intra-rater and Inter-rater Reliability of the Commander Pressure Algometer in Greek Patients With Chronic Neck Pain
    Skordis, Charalampos
    Liaskou, Christina
    Papagiakoumou, Evangelia
    Sotiropoulos, Spyridon
    Plavoukou, Theodora
    Karakasidou, Palina
    Georgoudis, George
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)