High intensity focused ultrasound ablation of kidney guided by MRI

被引:47
作者
Damianou, C
Pavlou, M
Velev, O
Kyriakou, K
Trimikliniotis, M
机构
[1] FIT, Limmasol, Cyprus
[2] Poliklin Igia, Limmasol, Cyprus
[3] Intercoll, Limmasol, Cyprus
关键词
ultrasound; kidney; MRI; lesion; cortex; cavitation;
D O I
10.1016/j.ultrasmedbio.2003.10.018
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The effectiveness of magnetic resonance imaging (MRI) to monitor therapeutic protocols of high-intensity focused ultrasound (HIFU), in freshly excised pig kidney cortex is investigated. For high quality imaging, the pulse sequence fast spin echo (FSE) T1- and T2-weighted, and proton density were evaluated. For fast imaging, the pulse sequence T1-weighted fast spoiled gradient (FSPGR) was used. The main goal was to evaluate the MRI detection of large lesions (bigger than 1 cm x 1 cm x 1 cm) that is achieved by moving the transducer in a predetermined pattern. The contrast between lesion and kidney tissue is excellent with either T1-weighted or T2-weighted FSE. With T1-weighted FSE, the best contrast is observed for recovery time (TR) between 200 ms and 400 ms. With T2-weighted FSE best contrast can be achieved for echo time (TE) between 16 and 32 ms. T2-weighted FSE was proven as the best pulse sequence to detect cavitational activity. This advantage is attributed to the significant difference in signal intensity between air spaces and necrotic tissue. Air spaces appear brighter than thermal lesions. Therefore, for therapeutic protocols created using cavitational mode, T2-weighted FSE may be the optimum pulse sequence to use. The proton density pulse sequence does not provide any advantage over the T1- and T2-weighted pulse sequences. Using T1-weighted FSPGR, acquisition time as low as 5 s could be achieved. Good contrast and signal-to-noise ratio (SNR) are achieved with TR = 100 ms and flip angle between 75 to 90degrees. The above techniques were very successful in detecting large lesion volumes. (C) 2004 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:397 / 404
页数:8
相关论文
共 52 条
[1]   REAL-TIME MAGNETIC-RESONANCE-IMAGING OF LASER HEAT DEPOSITION IN TISSUE [J].
BLEIER, AR ;
JOLESZ, FA ;
COHEN, MS ;
WEISSKOFF, RM ;
DALCANTON, JJ ;
HIGUCHI, N ;
FEINBERG, DA ;
ROSEN, BR ;
MCKINSTRY, RC ;
HUSHEK, SG .
MAGNETIC RESONANCE IN MEDICINE, 1991, 21 (01) :132-137
[2]  
Chen L, 1999, J MAGN RESON IMAGING, V10, P146, DOI 10.1002/(SICI)1522-2586(199908)10:2<146::AID-JMRI6>3.0.CO
[3]  
2-C
[4]   MAGNETIC RESONANCE-GUIDED THERMAL SURGERY [J].
CLINE, HE ;
SCHENCK, JF ;
WATKINS, RD ;
HYNYNEN, K ;
JOLESZ, FA .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (01) :98-106
[5]   MR TEMPERATURE MAPPING OF FOCUSED ULTRASOUND SURGERY [J].
CLINE, HE ;
HYNYNEN, K ;
HARDY, CJ ;
WATKINS, RD ;
SCHENCK, JF ;
JOLESZ, FA .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) :628-636
[6]   Simultaneous magnetic resonance phase and magnitude temperature maps in muscle [J].
Cline, HE ;
Hynynen, K ;
Schneider, E ;
Hardy, CJ ;
Maier, SE ;
Watkins, RD ;
Jolesz, FA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) :309-315
[7]   In vitro and in vivo ablation of porcine renal tissues using high-intensity focused ultrasound [J].
Damianou, C .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (09) :1321-1330
[8]  
DAMIANOU C, 2003, UNPUB ULTRASOUND MED
[9]   Dependence of ultrasonic attenuation and absorption in dog soft tissues on temperature and thermal dose [J].
Damianou, CA ;
Sanghvi, NT ;
Fry, FJ ;
MaassMoreno, R .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 102 (01) :628-634
[10]   ONLINE MONITORING OF ULTRASONIC SURGERY WITH MR-IMAGING [J].
DARKAZANLI, A ;
HYNYNEN, K ;
UNGER, EC ;
SCHENCK, JF .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (03) :509-514