Motion synchronisation patterns of the carotid atheromatous plaque from B-mode ultrasound

被引:12
作者
Golemati, Spyretta [1 ,2 ]
Patelaki, Eleni [1 ,3 ]
Gastounioti, Aimilia [4 ]
Andreadis, Ioannis [1 ,3 ]
Liapis, Christos D. [5 ]
Nikita, Konstantina S. [1 ,3 ]
机构
[1] Natl Tech Univ Athens, Sch Elect & Comp Engn, Biomed Simulat & Imaging Lab, Athens, Greece
[2] Natl & Kapodistrian Univ Athens, Med Sch, Athens, Greece
[3] Inst Commun & Comp Syst, Athens, Greece
[4] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[5] Natl & Kapodistrian Univ Athens, Attikon Univ Gen Hosp, Med Sch, Athens, Greece
关键词
ARTERY WALL; STRAIN INDEXES; BLOOD-PRESSURE; ATHEROSCLEROSIS; STENOSIS; RISK; QUANTIFICATION; CLASSIFICATION; RADIOFREQUENCY; TRACKING;
D O I
10.1038/s41598-020-65340-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Asynchronous movement of the carotid atheromatous plaque from B-mode ultrasound has been previously reported, and associated with higher risk of stroke, but not quantitatively estimated. Based on the hypothesis that asynchronous plaque motion is associated with vulnerable plaque, in this study, synchronisation patterns of different tissue areas were estimated using cross-correlations of displacement waveforms. In 135 plaques (77 subjects), plaque radial deformation was synchronised by approximately 50% with the arterial diameter, and the mean phase shift was 0.4s. Within the plaque, the mean phase shifts between the displacements of the top and bottom surfaces were 0.2s and 0.3s, in the radial and longitudinal directions, respectively, and the synchronisation about 80% in both directions. Classification of phase-shift-based features using Random Forests yielded Area-Under-the-Curve scores of 0.81, 0.79, 0.89 and 0.90 for echogenicity, symptomaticity, stenosis degree and plaque risk, respectively. Statistical analysis showed that echolucent, high-stenosis and high-risk plaques exhibited higher phase shifts between the radial displacements of their top and bottom surfaces. These findings are useful in the study of plaque kinematics.
引用
收藏
页数:13
相关论文
共 52 条
[1]   A Systematic Comparison of Supervised Classifiers [J].
Amancio, Diego Raphael ;
Comin, Cesar Henrique ;
Casanova, Dalcimar ;
Travieso, Gonzalo ;
Bruno, Odemir Martinez ;
Rodrigues, Francisco Aparecido ;
Costa, Luciano da Fontoura .
PLOS ONE, 2014, 9 (04)
[2]   A new method for analysis of motion of carotid plaques from RF ultrasound images [J].
Bang, J ;
Dahl, T ;
Bruinsma, A ;
Kaspersen, JH ;
Hernes, TAN ;
Myhre, HO .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (07) :967-976
[3]   Random forests [J].
Breiman, L .
MACHINE LEARNING, 2001, 45 (01) :5-32
[4]   Carotid Artery Plaque Vulnerability Assessment Using Noninvasive Ultrasound Elastography: Validation With MRI [J].
Cardinal, Marie-Helene Roy ;
Heusinkveld, Maarten H. G. ;
Qin, Zhao ;
Lopata, Richard G. P. ;
Naim, Cyrille ;
Soulez, Gilles ;
Cloutier, Guy .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 209 (01) :142-151
[5]   Longitudinal movements and resulting shear strain of the arterial wall [J].
Cinthio, Magnus ;
Ahlgren, sa Rydén ;
Bergkvist, Jonas ;
Jansson, Tomas ;
Persson, Hans W. ;
Lindström, Kjell .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2006, 291 (01) :H394-H402
[6]   Carotid atherosclerotic plaque instability and cognition determined by ultrasound-measured plaque strain in asymptomatic patients with significant stenosis [J].
Dempsey, Robert J. ;
Varghese, Tomy ;
Jackson, Daren C. ;
Wang, Xiao ;
Meshram, Nirvedh H. ;
Mitchell, Carol C. ;
Hermann, Bruce P. ;
Johnson, Sterling C. ;
Berman, Sara E. ;
Wilbrand, Stephanie M. .
JOURNAL OF NEUROSURGERY, 2018, 128 (01) :111-119
[7]  
Elatrozy T, 1998, INT ANGIOL, V17, P179
[8]  
Froio A., 2013, NONINVASIVE VASCULAR, P157
[9]   Carotid artery wall motion analysis from B-mode ultrasound using adaptive block matching: in silico evaluation and in vivo application [J].
Gastounioti, A. ;
Golemati, S. ;
Stoitsis, J. S. ;
Nikita, K. S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (24) :8647-8661
[10]   Comparison of Kalman-filter-based approaches for block matching in arterial wall motion analysis from B-mode ultrasound [J].
Gastounioti, A. ;
Golemati, S. ;
Stoitsis, J. ;
Nikita, K. S. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (11)