Microfluidic Analyzer Enabling Quantitative Measurements of Specific Intracellular Proteins at the Single-Cell Level

被引:2
|
作者
Liu, Lixing [1 ,2 ]
Fan, Beiyuan [1 ,2 ]
Wang, Diancan [3 ]
Li, Xiufeng [1 ,2 ]
Song, Yeqing [3 ]
Zhang, Ting [1 ,2 ]
Chen, Deyong [1 ,2 ]
Wang, Yixiang [3 ]
Wang, Junbo [1 ,2 ]
Chen, Jian [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100190, Peoples R China
[3] Peking Univ, Sch Stomatol, Beijing 10081, Peoples R China
来源
MICROMACHINES | 2018年 / 9卷 / 11期
基金
中国国家自然科学基金;
关键词
instrumentation; microfluidic flow cytometry; intracellular proteins; absolute quantification; FLOW-CYTOMETRY; HETEROGENEITY;
D O I
10.3390/mi9110588
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents a microfluidic instrument capable of quantifying single-cell specific intracellular proteins, which are composed of three functioning modules and two software platforms. Under the control of a LabVIEW platform, a pressure module flushed cells stained with fluorescent antibodies through a microfluidic module with fluorescent intensities quantified by a fluorescent module and translated into the numbers of specific intracellular proteins at the single-cell level using a MATLAB platform. Detection ranges and resolutions of the analyzer were characterized as 896.78-6.78 x 10(5) and 334.60 nM for Alexa 488, 314.60-2.11 x 10(5) and 153.98 nM for FITC, and 77.03-5.24 x 10(4) and 37.17 nM for FITC-labelled anti-beta-actin antibodies. As a demonstration, the numbers of single-cell beta-actins of two paired oral tumor cell types and two oral patient samples were quantified as: 1.12 +/- 0.77 x 10(6)/cell (salivary adenoid cystic carcinoma parental cell line (SACC-83), n(cell) = 13,689) vs. 0.90 +/- 0.58 x 10(5)/cell (salivary adenoid cystic carcinoma lung metastasis cell line (SACC-LM), n(cell) = 15,341); 0.89 +/- 0.69 x 10(6)/cell (oral carcinoma cell line (CAL 27), n(cell) = 7357) vs. 0.93 +/- 0.69 x 10(6)/cell (oral carcinoma lymphatic metastasis cell line (CAL 27-LN2), n(cell) = 6276); and 0.86 +/- 0.52 x 10(6)/cell (patient I) vs. 0.85 +/- 0.58 x 10(6)/cell (patient II). These results (1) validated the developed analyzer with a throughput of 10 cells/s and a processing capability of similar to 10,000 cells for each cell type, and (2) revealed that as an internal control in cell analysis, the expressions of beta-actins remained stable in oral tumors with different malignant levels.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Joint single-cell measurements of nuclear proteins and RNA in vivo
    Hattie Chung
    Christopher N. Parkhurst
    Emma M. Magee
    Devan Phillips
    Ehsan Habibi
    Fei Chen
    Bertrand Z. Yeung
    Julia Waldman
    David Artis
    Aviv Regev
    Nature Methods, 2021, 18 : 1204 - 1212
  • [32] Joint single-cell measurements of nuclear proteins and RNA in vivo
    Chung, Hattie
    Parkhurst, Christopher N.
    Magee, Emma M.
    Phillips, Devan
    Habibi, Ehsan
    Chen, Fei
    Yeung, Bertrand Z.
    Waldman, Julia
    Artis, David
    Regev, Aviv
    NATURE METHODS, 2021, 18 (10) : 1204 - +
  • [33] Cultivation and quantitative single-cell analysis of Saccharomyces cerevisiae on a multifunctional microfluidic device
    Stratz, Simone
    Verboket, Pascal Emilio
    Hasler, Karina
    Dittrich, Petra Stephanie
    ELECTROPHORESIS, 2018, 39 (03) : 540 - 547
  • [34] T cell activation on a single-cell level in dielectrophoresis-based microfluidic devices
    Kirschbaum, Michael
    Jaeger, Magnus Sebastian
    Schenkel, Tim
    Breinig, Tania
    Meyerhans, Andreas
    Duschl, Claus
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1202 (01) : 83 - 89
  • [35] A microfluidic platform with pneumatically switchable single-cell traps for selective intracellular signals probing
    Wang, Yao
    Zhu, Jinchi
    Chen, Peng
    Hu, Liang
    Feng, Xiaojun
    Du, Wei
    Liu, Bi-Feng
    TALANTA, 2019, 192 : 431 - 438
  • [36] Quantitative Extraction and Mass Spectrometry Analysis at a Single-Cell Level
    Yin, Ruichuan
    Prabhakaran, Venkateshkumar
    Laskin, Julia
    ANALYTICAL CHEMISTRY, 2018, 90 (13) : 7937 - 7945
  • [37] Determining intracellular temperature at single-cell level by a novel thermocouple method
    Wang, Changling
    Xu, Ruizhi
    Tian, Wenjuan
    Jiang, Xiaoli
    Cui, Zhengyu
    Wang, Meng
    Sun, Huaming
    Fang, Kun
    Gu, Ning
    CELL RESEARCH, 2011, 21 (10) : 1517 - 1519
  • [38] A high precision apparatus for intracellular thermal response at single-cell level
    Tian, Wenjuan
    Wang, Cangling
    Wang, Jianqing
    Chen, Qiuhua
    Sun, Jianfei
    Li, Can
    Wang, Xing
    Gu, Ning
    NANOTECHNOLOGY, 2015, 26 (35)
  • [39] Determining intracellular temperature at single-cell level by a novel thermocouple method
    Changling Wang
    Ruizhi Xu
    Wenjuan Tian
    Xiaoli Jiang
    Zhengyu Cui
    Meng Wang
    Huaming Sun
    Kun Fang
    Ning Gu
    Cell Research, 2011, 21 : 1517 - 1519
  • [40] Microfluidic Cell Trapping for Single-Cell Analysis
    Deng, Bing
    Wang, Heyi
    Tan, Zhaoyi
    Quan, Yi
    MICROMACHINES, 2019, 10 (06)