Audible Noise From Amorphous Metal and Silicon Steel-Based Transformer Core

被引:29
作者
Azuma, Daichi [1 ]
Hasegawa, Ryusuke [1 ]
机构
[1] Metglas Inc, Conway, SC 29526 USA
关键词
Amorphous magnetic materials; audible noise; audible noise measurement; transformer core;
D O I
10.1109/TMAG.2008.2003174
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Model cores based on amorphous SA1 and HB1 alloys for pole transformers were prepared and their audible noise was measured in terms of A-weighted sound power level in a hemi-anechoic chamber in accordance with ISO 3744 standard. The two amorphous cores annealed under optimum conditions to minimize the audible noise showed the same sound power level of 56 dB as M3 core at their typical operating flux densities. It was found that A-weighted sound power levels increased above 1.4 T for SA1 core and above 1.5 T for HB1 core. This provides design limitations for transformer cores based on amorphous alloys.
引用
收藏
页码:4104 / 4106
页数:3
相关论文
共 6 条
  • [1] *IEC, 2001, IEC6007610, pH9503
  • [2] *IEEE, 1999, C571290 IEEE, pH9503
  • [3] *ISO, 1994, 3744 ISO, pH9503
  • [4] *JIS, 2005, C4304 JIS, pH9503
  • [5] AMORPHOUS ALLOY CORE DISTRIBUTION TRANSFORMERS
    NG, HW
    HASEGAWA, R
    LEE, AC
    LOWDERMILK, LA
    [J]. PROCEEDINGS OF THE IEEE, 1991, 79 (11) : 1608 - 1623
  • [6] Magnetic properties of high Bs Fe-based amorphous material
    Ogawa, Yuichi
    Naoe, Masamu
    Yoshizawa, Yoshihito
    Hasegawa, Ryusuke
    [J]. JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2006, 304 (02) : E675 - E677