Model experiment on physiologically intermittent flow in an aortic arch

被引:2
|
作者
Konno, T [1 ]
Satoh, Y [1 ]
Tanishita, K [1 ]
机构
[1] Keio Univ, Inst Biomed Engn, Kohoku Ku, Yokohama, Kanagawa 2238522, Japan
关键词
bio-fluid mechanics; biomechanics; biological engineering; curved tube; secondary flow; aortic arch;
D O I
10.1299/jsmec.42.648
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The aortic blood flow is characterized by the intermittent entry flow in a strongly curved tube because of the presence of stationary diastolic period. In this study we measured the axial and secondary velocity of intermittent flow in a strongly curved tube simulating the blood flow in an aortic arch (the ratio of the tube radius to the radius of curvature = 1/3, Dean number = 791) by Laser Doppler Velocimeter. In order to reveal the effect of diastolic period (t(d)) on the flow development, t(d) ranges from 0.4 to 2.0 sec, whereas the systolic period remains constant (0.4 sec). During the deceleration phase of the systolic period, reversed axial flow starts to appear near the inner wall. This reversed axial flow becomes significant at the end of systolic phase and causes to induce the new secondary flow development. For t(d) = 0.4 sec flow does not diminish completely until the end of the diastolic period and affects the flow development in the following systolic period. This secondary flow augmentation in the beginning of diastolic phase is remarkable in the entry region of curved tube.
引用
收藏
页码:648 / 655
页数:8
相关论文
共 50 条
  • [1] Numerical Simulation of Blood Flow crossing the Aortic arch
    Kao, Rui-Hung
    Kan, Chung-Dann
    Chen, Wei-Ling
    Leu, Tzong-Shyng
    1ST INTERNATIONAL CONFERENCE ON ORANGE TECHNOLOGIES (ICOT 2013), 2013, : 119 - 122
  • [2] Diastolic rotational flow in the aortic arch
    Gary Dobson
    Neil Maher
    Paul Petrasek
    Clifton Johnston
    Canadian Journal of Anaesthesia, 2007, 54 : 1017 - 1018
  • [3] Diastolic rotational flow in the aortic arch
    Dobson, Gary
    Maher, Neil
    Petrasek, Paul
    Johnston, Clifton
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2007, 54 (12): : 1017 - 1018
  • [4] Stress analysis in a layered aortic arch model under pulsatile blood flow
    Feng Gao
    Masahiro Watanabe
    Teruo Matsuzawa
    BioMedical Engineering OnLine, 5
  • [5] Unsteady and three-dimensional simulation of blood flow in the human aortic arch
    Shahcheraghi, N
    Dwyer, HA
    Cheer, AY
    Barakat, AI
    Rutaganira, T
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (04): : 378 - 387
  • [6] Numerical Simulation of Blood Flow Through the Aortic Arch
    Seta, Berin
    Torlak, Muris
    Vila, Alija
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING 2017 (CMBEBIH 2017), 2017, 62 : 259 - 268
  • [7] A mathematical model for biomechanical behavior of the aortic arch
    Zandvakili, Hamid
    Hassani, Kamran
    Khorramymehr, Siamak
    PERFUSION-UK, 2023, 38 (05): : 1012 - 1018
  • [8] Mouse model of heterotopic aortic arch transplantation
    Chereshnev, I
    Trogan, E
    Omerhodzic, S
    Itskovich, V
    Aguinaldo, JG
    Fayad, ZA
    Fisher, EA
    Reis, ED
    JOURNAL OF SURGICAL RESEARCH, 2003, 111 (02) : 171 - 176
  • [9] Three-dimensional lattice Boltzmann method for simulating blood flow in aortic arch
    康秀英
    吉驭嫔
    刘大禾
    金永娟
    Chinese Physics B, 2008, 17 (03) : 1041 - 1049
  • [10] Three-dimensional lattice Boltzmann method for simulating blood flow in aortic arch
    Kang Xiu-Ying
    Ji Yu-Pin
    Liu Da-He
    Jin Yong-Juan
    CHINESE PHYSICS B, 2008, 17 (03) : 1041 - 1049