Bead-based multiplex detection of dengue biomarkers in a portable imaging device

被引:10
作者
Yuan, Xilong [1 ]
Garg, Srishti [1 ]
De Haan, Kevin [1 ,2 ]
Fellouse, Frederic A. [3 ,4 ]
Gopalsamy, Anupriya [3 ,4 ]
Tykvart, Jan [3 ,4 ,5 ]
Sidhu, Sachdev S. [3 ,4 ]
Varma, Manoj M. [6 ]
Pal, Parama [7 ]
Hillan, Edith M. [8 ]
Dou, James Jiahua [9 ]
Aitchison, J. Stewart [1 ]
机构
[1] Univ Toronto, Dept Elect & Comp Engn, Toronto, ON, Canada
[2] Univ Calif Los Angeles, Dept Elect & Comp Engn, Los Angeles, CA 90095 USA
[3] Univ Toronto, Donnelly Ctr, Toronto, ON, Canada
[4] Univ Toronto, Dept Med Genet, Toronto, ON, Canada
[5] DIANA Biotechnol Sro, Vestec 25250, Czech Republic
[6] Indian Inst Sci, Ctr Nano Sci & Engn, Bengaluru, Karnataka, India
[7] Tata Consultancy Serv, TCS Res & Innovat, Bengaluru, Karnataka, India
[8] Univ Toronto, Lawrence S Bloomberg Fac Nursing, Toronto, ON, Canada
[9] Thinkari Res Inc, Mississauga, ON, Canada
关键词
OF-CARE TESTS; FLOW-CYTOMETRY; ANTIGEN; NS1; MICROSPHERES; DIAGNOSIS; DISEASE;
D O I
10.1364/BOE.403803
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Dengue is one of the most rapidly spreading mosquito-borne viral diseases in the world. Differential diagnosis is a crucial step for the management of the disease and its epidemiology. Point-of-care testing of blood-borne dengue biomarkers provides an advantageous approach in many health care settings, and the ability to follow more than one biomarker at once could significantly improve the management of the disease. Bead-based multiplex technologies (suspension array) can measure multiple biomarker targets simultaneously by using recognition molecules immobilized on microsphere beads. The overarching objective of our work is to develop a portable detection device for the simultaneous measurement of multiple biomarkers important in dengue diagnosis, monitoring and treatment. Here, we present a bead-based assay for the detection of one of the four serotypes of dengue virus non-structural protein (DENV-NS1) as well as its cognate human IgG. In this system, the fluorescent microspheres containing the classification fluorophore and detection fluorophore are imaged through a microfluidic chip using an infinity-corrected microscope system. Calibration curves were plotted for median fluorescence intensity against known concentrations of DENV-NS1 protein and anti-NS1 human IgG. The limit of quantitation was 7.8 ng/mL and 15.6 ng/mL, respectively. The results of this study demonstrate the feasibility of the multiplex detection of dengue biomarkers and present its analytical performance parameters. The proposed imaging device holds potential for point-of-care testing of biomarkers on a highly portable system, and it may facilitate the diagnosis and prevention of dengue as well as other infectious diseases. (C) 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:6154 / 6167
页数:14
相关论文
共 50 条
  • [21] Development of a bead-based multiplex immunoassay for simultaneous quantitative detection of IgG serum antibodies against seven vaccine-preventable diseases
    Bykonia, Evgeniia N.
    Kleymenov, Denis A.
    Mazunina, Elena P.
    Popova, Liubov I.
    Manuylov, Victor A.
    Gushchin, Vladimir A.
    Tkachuk, Artem P.
    Gintsburg, Alexander L.
    JOURNAL OF IMMUNOLOGICAL METHODS, 2023, 512
  • [22] Development of a Bead-Based Multiplex Assay for the Simultaneous Quantification of Three Staphylococcal Enterotoxins in Food by Flow Cytometry
    Anna Shepelyakovskaya
    Natalia Rudenko
    Anna Karatovskaya
    Margarita Shchannikova
    Irina Shulcheva
    Ksenia Fursova
    Anna Zamyatina
    Khanafi Boziev
    Vladimir Oleinikov
    Fedor Brovko
    Food Analytical Methods, 2020, 13 : 1202 - 1210
  • [23] Clinical value of multiplexed bead-based immunoassays for detection of autoantibodies to nuclear antigens
    Avaniss-Aghajani, Erik
    Berzon, Sophia
    Sarkissian, Arlen
    CLINICAL AND VACCINE IMMUNOLOGY, 2007, 14 (05) : 505 - 509
  • [24] Silica bead-based microfluidic device with integrated photodiodes for the rapid capture and detection of rolling circle amplification products in the femtomolar range
    Soares, Ruben R. G.
    Neumann, Felix
    Caneira, Catarina R. F.
    Madaboosi, Narayanan
    Ciftci, Sibel
    Hernandez-Neuta, Ivan
    Pinto, Ines F.
    Santos, Denis R.
    Chu, Virginia
    Russom, Aman
    Conde, Joao P.
    Nilsson, Mats
    BIOSENSORS & BIOELECTRONICS, 2019, 128 : 68 - 75
  • [25] Magnetic Bead-Based Multiplex DNA Sequence Detection of Genetically Modified Organisms Using Quantum Dot-Encoded Silicon Dioxide Nanoparticles
    Zhao, Yuan
    Hao, Changlong
    Ma, Wei
    Yong, Qianqian
    Yan, Wenjing
    Kuang, Hua
    Wang, Libing
    Xu, Chuanlai
    JOURNAL OF PHYSICAL CHEMISTRY C, 2011, 115 (41) : 20134 - 20140
  • [26] Aberrant tumor-associated antigen autoantibody profiles in healthy controls detected by multiplex bead-based immunoassay
    Nolen, Brian
    Winans, Matt
    Marrangoni, Adele
    Lokshin, Anna
    JOURNAL OF IMMUNOLOGICAL METHODS, 2009, 344 (02) : 116 - 120
  • [27] Development of a Bead-Based Multiplex Assay for Use in Multianalyte Screening and Surveillance of HIV, Viral Hepatitis, Syphilis, and Herpes
    Yufenyuy, Ernest L.
    Vedapuri, Shanmugam
    Zheng, Amy
    Cooley, Gretchen
    Danavall, Damien
    Mayur, Shukla
    Kodani, Maja
    Chen, Cheng
    Tun, Ye
    Fakile, Yetunde F.
    Martin, Diana
    Kamili, Saleem
    Karem, Kevin
    Parekh, Bharat S.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2022, 60 (05)
  • [28] Identification of a Small GTPase Inhibitor Using a High-Throughput Flow Cytometry Bead-Based Multiplex Assay
    Surviladze, Zurab
    Waller, Anna
    Wu, Yang
    Romero, Elsa
    Edwards, Bruce S.
    Wandinger-Ness, Angela
    Sklar, Larry A.
    JOURNAL OF BIOMOLECULAR SCREENING, 2010, 15 (01) : 10 - 20
  • [29] Development of a bead-based suspension array for the detection of pathogens in acute respiratory tract infections
    Chen, Yu-Sheng
    Li, Hong-Ru
    Zhang, Wei
    Hua, Zhi-Dan
    Lin, Xiao-Hong
    Lin, Meng-Qing
    Huang, Wen-Sen
    Huang, Li-Ping
    Yu, Xiao-Li
    Xu, Neng-Luan
    Lin, Ming
    Xie, Bao-Song
    Shen, Xiao-Na
    Xie, Jian-Feng
    Wang, Yi
    Huang, Meng
    Wu, Yan-An
    Hu, Xin-Lan
    EXPERIMENTAL BIOLOGY AND MEDICINE, 2016, 241 (14) : 1551 - 1558
  • [30] A Magnetic Bead-Based Method for Concentrating DNA from Human Urine for Downstream Detection
    Bordelon, Hali
    Russ, Patricia K.
    Wright, David W.
    Haselton, Frederick R.
    PLOS ONE, 2013, 8 (07):