Bead-based multiplex detection of dengue biomarkers in a portable imaging device

被引:10
作者
Yuan, Xilong [1 ]
Garg, Srishti [1 ]
De Haan, Kevin [1 ,2 ]
Fellouse, Frederic A. [3 ,4 ]
Gopalsamy, Anupriya [3 ,4 ]
Tykvart, Jan [3 ,4 ,5 ]
Sidhu, Sachdev S. [3 ,4 ]
Varma, Manoj M. [6 ]
Pal, Parama [7 ]
Hillan, Edith M. [8 ]
Dou, James Jiahua [9 ]
Aitchison, J. Stewart [1 ]
机构
[1] Univ Toronto, Dept Elect & Comp Engn, Toronto, ON, Canada
[2] Univ Calif Los Angeles, Dept Elect & Comp Engn, Los Angeles, CA 90095 USA
[3] Univ Toronto, Donnelly Ctr, Toronto, ON, Canada
[4] Univ Toronto, Dept Med Genet, Toronto, ON, Canada
[5] DIANA Biotechnol Sro, Vestec 25250, Czech Republic
[6] Indian Inst Sci, Ctr Nano Sci & Engn, Bengaluru, Karnataka, India
[7] Tata Consultancy Serv, TCS Res & Innovat, Bengaluru, Karnataka, India
[8] Univ Toronto, Lawrence S Bloomberg Fac Nursing, Toronto, ON, Canada
[9] Thinkari Res Inc, Mississauga, ON, Canada
关键词
OF-CARE TESTS; FLOW-CYTOMETRY; ANTIGEN; NS1; MICROSPHERES; DIAGNOSIS; DISEASE;
D O I
10.1364/BOE.403803
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Dengue is one of the most rapidly spreading mosquito-borne viral diseases in the world. Differential diagnosis is a crucial step for the management of the disease and its epidemiology. Point-of-care testing of blood-borne dengue biomarkers provides an advantageous approach in many health care settings, and the ability to follow more than one biomarker at once could significantly improve the management of the disease. Bead-based multiplex technologies (suspension array) can measure multiple biomarker targets simultaneously by using recognition molecules immobilized on microsphere beads. The overarching objective of our work is to develop a portable detection device for the simultaneous measurement of multiple biomarkers important in dengue diagnosis, monitoring and treatment. Here, we present a bead-based assay for the detection of one of the four serotypes of dengue virus non-structural protein (DENV-NS1) as well as its cognate human IgG. In this system, the fluorescent microspheres containing the classification fluorophore and detection fluorophore are imaged through a microfluidic chip using an infinity-corrected microscope system. Calibration curves were plotted for median fluorescence intensity against known concentrations of DENV-NS1 protein and anti-NS1 human IgG. The limit of quantitation was 7.8 ng/mL and 15.6 ng/mL, respectively. The results of this study demonstrate the feasibility of the multiplex detection of dengue biomarkers and present its analytical performance parameters. The proposed imaging device holds potential for point-of-care testing of biomarkers on a highly portable system, and it may facilitate the diagnosis and prevention of dengue as well as other infectious diseases. (C) 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:6154 / 6167
页数:14
相关论文
共 50 条
  • [1] Development of a Multiplex Bead-Based Assay for Detection of Hepatitis C Virus
    Fonseca, Bruna P. F.
    Marques, Christiane F. S.
    Nascimento, Lilian D.
    Mello, Marcelle B.
    Silva, Leila B. R.
    Rubim, Nara M.
    Foti, Leonardo
    Silva, Edimilson D.
    Ferreira, Antonio G. P.
    Krieger, Marco A.
    CLINICAL AND VACCINE IMMUNOLOGY, 2011, 18 (05) : 802 - 806
  • [2] Development of a Multiplex Bead-Based Method for the Microquantitation of δ-Catenin
    Lee, Mijin
    Tas, Isa
    Zhou, Rui
    Jung, Sang-Chul
    Kim, Kwonseop
    Kim, Hangun
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2020, 20 (09) : 5819 - 5822
  • [3] Bead-based spontaneous Raman codes for multiplex immunoassay
    Ma, Weiwei
    He, Caili
    Shen, Chengyue
    Zhang, Guihao
    Pan, Jun
    Tang, Yuchen
    Wang, Jinzhi
    Gao, Tingjuan
    ANALYTICA CHIMICA ACTA, 2024, 1316
  • [4] A novel multiplex bead-based platform highlights the diversity of extracellular vesicles
    Koliha, Nina
    Wiencek, Yvonne
    Heider, Ute
    Juengst, Christian
    Kladt, Nikolay
    Krauthaeuser, Susanne
    Johnston, Ian C. D.
    Bosio, Andreas
    Schauss, Astrid
    Wild, Stefan
    JOURNAL OF EXTRACELLULAR VESICLES, 2016, 5
  • [5] Development of a bead-based multiplex PCR assay for the simultaneous detection of multiple Mycoplasma species
    Righter, Daniel J.
    Rurangirwa, Fred R.
    Call, Douglas R.
    McElwain, Terry F.
    VETERINARY MICROBIOLOGY, 2011, 153 (3-4) : 246 - 256
  • [6] Borrelia multiplex: a bead-based multiplex assay for the simultaneous detection of Borrelia specific IgG/IgM class antibodies
    Haring, Julia
    Hassenstein, Max J.
    Becker, Matthias
    Ortmann, Julia
    Junker, Daniel
    Karch, Andre
    Berger, Klaus
    Tchitchagua, Tatia
    Leschnik, Olaf
    Harries, Manuela
    Gornyk, Daniela
    Hernandez, Pilar
    Lange, Berit
    Castell, Stefanie
    Krause, Gerard
    Dulovic, Alex
    Strengert, Monika
    Schneiderhan-Marra, Nicole
    BMC INFECTIOUS DISEASES, 2022, 22 (01)
  • [7] A bead-based immunofluorescence-assay on a microfluidic dielectrophoresis platform for rapid dengue virus detection
    Iswardy, Edwar
    Tsai, Tien-Chun
    Cheng, I-Fang
    Ho, Tzu-Chuan
    Perng, Guey Chuen
    Chang, Hsien-Chang
    BIOSENSORS & BIOELECTRONICS, 2017, 95 : 174 - 180
  • [8] Detection of Anti-Toxoplasma gondii Antibodies in Human Sera Using Synthetic Glycosylphosphatidylinositol Glycans on a Bead-Based Multiplex Assay
    Garg, Monika
    Stern, Daniel
    Gross, Uwe
    Seeberger, Peter H.
    Seeber, Frank
    Silva, Daniel Varon
    ANALYTICAL CHEMISTRY, 2019, 91 (17) : 11215 - 11222
  • [9] Validation of a commercial magnetic bead-based multiplex assay for 5 novel biomarkers of acute kidney injury in canine serum
    Davis, Jennifer
    Raisis, Anthea L.
    Miller, David W.
    Rossi, Gabriele
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2020, 32 (05) : 656 - 663
  • [10] A Magnetic Bead-Based Sensor for the Quantification of Multiple Prostate Cancer Biomarkers
    Jokerst, Jesse V.
    Chen, Zuxiong
    Xu, Lingyun
    Nolley, Rosalie
    Chang, Edwin
    Mitchell, Breeana
    Brooks, James D.
    Gambhir, Sanjiv S.
    PLOS ONE, 2015, 10 (09):