Active Filter Under Unbalanced And Distorted Conditions

被引:0
|
作者
Djazia, K. [1 ]
Krim, F. [1 ]
Sarra, M. [1 ]
机构
[1] Univ Setif, Power Elect & Ind Control Lab LEPCI, Setif, Algeria
关键词
Active filters; Harmonic; Instantaneous reactive power; Unbalanced and distorted systems; VOLTAGE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes the design and implementation of a new control method of shunt active filter to achieve near-sinuso dal source current waveform under unbalanced and distorted source voltage conditions. The proposed configuration, based on instantaneous active and reactive powers (pq method), uses the high selectivity extraction multivariable filters (MVF). These latters permit overall extraction of harmonic currents and reactive power references in order to achieve their compensation. Simulation results have proved excellent performance, and verify the validity of the proposed method, which are much better than conventional methods.
引用
收藏
页码:664 / 669
页数:6
相关论文
共 50 条
  • [21] A SPLL Technique under Unbalanced and Seriously Distorted Grid Voltage Conditions
    Dang, Cun-lu
    Zhao, Xiao-gang
    26TH CHINESE CONTROL AND DECISION CONFERENCE (2014 CCDC), 2014, : 4523 - 4528
  • [22] POWER QUALITY ENHANCEMENT STRATEGY OF MICROGRID UNDER DISTORTED AND UNBALANCED CONDITIONS
    Wang, Ruiqi
    Li, Yunwei
    Zhang, Chenghui
    INTERNATIONAL JOURNAL OF POWER AND ENERGY SYSTEMS, 2015, 35 (03): : 105 - 112
  • [23] Novel PLL for power converters under unbalanced and distorted grid conditions
    Wang, Jianguo
    Wang, Jihong
    Luo, Xing
    JOURNAL OF ENGINEERING-JOE, 2019, (17): : 3895 - 3899
  • [24] Comparison of reference current generation techniques for non-active power compensation under distorted and unbalanced conditions
    Ordonez, Rafael
    Karimi, Charif
    Oueidat, Mohamad
    Sadarnac, Daniel
    IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11, 2006, : 1680 - +
  • [25] Analysis of reference current identification strategies for shunt active filter under distorted load conditions
    Teta, Ali
    Rezaoui, Mohamed Mounir
    Kouzou, Abdellah
    Laouid, Abdelkader Azzeddine
    Bensaoucha, Saddam
    PROCEEDINGS 2018 3RD INTERNATIONAL CONFERENCE ON ELECTRICAL SCIENCES AND TECHNOLOGIES IN MAGHREB (CISTEM), 2018, : 233 - 238
  • [26] Active Power Filtering Under Unbalanced and Distorted Grid Conditions Using Modular Fundamental Element Detection Technique
    Hoon, Yap
    Zainuri, Muhammad Ammirrul Atiqi Mohd
    Al-Ogaili, Ali Saadon
    Al-Masri, Ahmed N.
    Teh, Jiashen
    IEEE ACCESS, 2021, 9 : 107502 - 107518
  • [27] Adaptive Notch Filter Applied to Hybrid Active Var Compensator under Nonsinusoidal and Unbalanced Conditions
    Ferreira, S. C.
    Gonzatti, R. B.
    Silva, C. H.
    Silva, L. E. B.
    Lambert-Torres, G.
    Silva, L. G. F.
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 2264 - 2269
  • [28] A novel technique for implementation of Shunt Active Power Filter under balanced and unbalanced load conditions
    Karvekar, Sushil
    Patil, Dadgonda
    Proceedings of IEEE International Conference on Circuit, Power and Computing Technologies, ICCPCT 2013, 2013, : 1 - 5
  • [29] A Novel Technique For Implementation of Shunt Active Power Filter Under Balanced And Unbalanced Load Conditions
    Karvekar, Sushil
    Patil, Dadgonda
    PROCEEDINGS OF 2013 INTERNATIONAL CONFERENCE ON CIRCUITS, POWER AND COMPUTING TECHNOLOGIES (ICCPCT 2013), 2013, : 1 - 5
  • [30] Average current mode to control the three phase shunt active power filters under distorted and unbalanced voltage conditions
    Department of Physics, Faculty of Sciences Semlalia, Cadi Ayyad University, BP 2 390, Marrakech 40 000, Morocco
    Modell Meas Control A, 2007, 1-2 (68-81):