Long-term stability of biomarkers of the iron status in human serum and plasma

被引:16
|
作者
Jansen, Eugene H. J. M. [1 ]
Beekhof, Piet K. [1 ]
Schenk, Erna [1 ]
机构
[1] Natl Inst Publ Hlth & Environm, Ctr Hlth Protect, NL-3720 BA Bilthoven, Netherlands
关键词
Ceruloplasmin; ferritin; haptoglobin; storage; total iron; transferrin; transferrin receptor; UIBC; CARDIOVASCULAR-DISEASE; RISK; ANALYTES; STORES; TRANSFERRIN; STORAGE; CANCER; COHORT; TUBES; WOMEN;
D O I
10.3109/1354750X.2013.781223
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Context: In epidemiological research, it is very important to test the stability of biomarkers as function of both storage time and temperature. Objective: In this study, the stability of biomarkers of the iron status was tested up to 1 year of storage. Materials and methods: The biomarkers include total iron, unsaturated iron binding capacity, ferritin, transferrin, soluble transferrin receptor, ceruloplasmin and haptoglobin. Results: The concentrations of all biomarkers tested remain constant upon storage at -20, -70 and -196 degrees C. Conclusion: All biomarkers of the iron status were stable at the temperatures tested for 1 year.
引用
收藏
页码:365 / 368
页数:4
相关论文
共 50 条
  • [1] Very long-term stability of lipid biomarkers in human serum
    Muzakova, Vladimira
    Beekhof, Piet K.
    Jansen, Eugene H. J. M.
    ANALYTICAL BIOCHEMISTRY, 2020, 597
  • [2] Long-term stability of oxidative stress biomarkers in human serum
    Jansen, Eugene H. J. M.
    Beekhof, Piet K.
    Viezeliene, Dale
    Muzakova, Vladimira
    Skalicky, Jiri
    FREE RADICAL RESEARCH, 2017, 51 (11-12) : 970 - 977
  • [3] Long-term stability of parameters of antioxidant status in human serum
    Jansen, E. H. J. M.
    Beekhof, P. K.
    Cremers, J. W. J. M.
    Viezeliene, D.
    Muzakova, V.
    Skalicky, J.
    FREE RADICAL RESEARCH, 2013, 47 (6-7) : 535 - 540
  • [4] Long-term stability of cancer biomarkers in human serum: biomarkers of oxidative stress and redox status, homocysteine, CRP and the enzymes ALT and GGT
    Jansen, Eugene
    Beekhof, Piet
    Viezeliene, Dale
    Muzakova, Vladimira
    Skalicky, Jiri
    BIOMARKERS IN MEDICINE, 2015, 9 (05) : 425 - 432
  • [5] Long-term stability of nelfinavir mesylate in human plasma
    Turner, ML
    Acosta, EP
    CLINICAL CHEMISTRY, 2000, 46 (12) : 2019 - 2020
  • [6] LONG-TERM STABILITY OF HORMONES IN SERUM
    VASILIADES, J
    HILGERS, T
    GENTRUP, B
    CLINICAL CHEMISTRY, 1995, 41 (06) : S59 - S59
  • [7] SERUM HEPCIDIN LEVELS AND IRON STATUS DURING LONG-TERM ENDURANCE EXERCISE
    Jerin, A.
    Auersperger, I.
    Skof, B.
    Knap, B.
    Blagus, R.
    Lainscak, M.
    Skitek, M.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S472 - S472
  • [8] The long-term stability of plasma spraying
    L. Leblanc
    C. Moreau
    Journal of Thermal Spray Technology, 2002, 11 : 380 - 386
  • [9] The long-term stability of plasma spraying
    Leblanc, L
    Moreau, C
    JOURNAL OF THERMAL SPRAY TECHNOLOGY, 2002, 11 (03) : 380 - 386
  • [10] Effect of biobanking conditions on short-term stability of biomarkers in human serum and plasma
    Zander, Johannes
    Bruegel, Mathias
    Kleinhempel, Alisa
    Becker, Susen
    Petros, Sirak
    Kortz, Linda
    Dorow, Juliane
    Kratzsch, Juergen
    Baber, Ronny
    Ceglarek, Uta
    Thiery, Joachim
    Teupser, Daniel
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (05) : 629 - 639