Supramolecular complex based on MWNTs/Boltorn H40 provides fast response to a Sandwich-type amperometric lactate biosensor

被引:14
作者
Romero, Marcelo R. [1 ]
Peralta, Damian [1 ]
Alvarez Igarzabal, Cecilia I. [1 ]
Baruzzi, Ana M. [2 ]
Strumia, Miriam C. [1 ]
Garay, Fernando [2 ]
机构
[1] Univ Nacl Cordoba, Fac Ciencias Quim, Dept Quim Organ, IMBIV,CONICET, RA-5000 Cordoba, Argentina
[2] Univ Nacl Cordoba, Fac Ciencias Quim, Dept Quim Fis, INFIQC,CONICET, RA-5000 Cordoba, Argentina
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2017年 / 244卷
关键词
Self-assembled; Sandwich-type biosensor; Lactate; Nanotube; Hydrogel; Hyperbranched; WALLED CARBON NANOTUBES; SINGLE-WALL; ELECTROCHEMICAL BIOSENSORS; HYDROGEL; OXIDASE; OPTIMIZATION; FABRICATION; MATRIX;
D O I
10.1016/j.snb.2017.01.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Most sandwich-type biosensors can be used several times, since their long-time stability generally ranges from weeks to several months. However, the response-time of this kind of sensors is typically slow because reagents and products have to diffuse through filtering membranes and the enzymatic matrix. In this manuscript, multiwalled carbon nanotubes (MWNTs) have been used for wiring the enzymatic matrix to the electrode surface. To achieve this, the hyperbranched polymer Boltorn H40 (BH40) has been self-assembled at the surface of MWNTs. After the assembling, the suspension of BH40-MWNTs became stable and its functionality was tested by replacing mucin in the enzymatic matrix of a previously reported sandwich-type lactate biosensor. The inclusion of BH40-MWNTs in the biosensor: increased the diffusion coefficient of soluble species by decreasing the elastic properties of the enzymatic matrix, kept the characteristics of the microenvironment where the enzyme is stored, and wired the enzymatic matrix through a 13 mu m thick polycarbonate membrane to the electrode surface. It is important to understand that the superstructure of BH40-MWNTs does not increase the active surface of the electrode. Instead of this, it is a conductive 3D network that connects the enzymatic matrix to the electrode. As a result, the response-time of this novel sandwich-type lactate biosensor is much shorter than that of conventional biosensors because the mediator of the enzyme (oxygen) can be regenerated at the enzymatic matrix and it does not have to diffuse to the electrode surface. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:577 / 584
页数:8
相关论文
共 43 条
  • [1] Carbon Nanomaterials Based Electrochemical Sensors/Biosensors for the Sensitive Detection of Pharmaceutical and Biological Compounds
    Adhikari, Bal-Ram
    Govindhan, Maduraiveeran
    Chen, Aicheng
    [J]. SENSORS, 2015, 15 (09) : 22490 - 22508
  • [2] Hybrid hydrogels containing vertically aligned carbon nanotubes with anisotropic electrical conductivity for muscle myofiber fabrication
    Ahadian, Samad
    Ramon-Azcon, Javier
    Estili, Mehdi
    Liang, Xiaobin
    Ostrovidov, Serge
    Shiku, Hitoshi
    Ramalingam, Murugan
    Nakajima, Ken
    Sakka, Yoshio
    Bae, Hojae
    Matsue, Tomokazu
    Khademhosseini, Ali
    [J]. SCIENTIFIC REPORTS, 2014, 4
  • [3] Barrera EV, 2005, CARBON NANOTUBES: SCIENCE AND APPLICATIONS, P253
  • [4] Independent Pathway Formation of Guest-Host in Host Ternary Complexes Made of Ammonium Salt, Calixarene, and Cyclodextrin
    Basilio, Nuno
    Francisco, Vitor
    Garcia-Rio, Luis
    [J]. JOURNAL OF ORGANIC CHEMISTRY, 2012, 77 (23) : 10764 - 10772
  • [5] Measurement of nonlinear rheology of cross-linked biopolymer gels
    Broedersz, Chase P.
    Kasza, Karen E.
    Jawerth, Louise M.
    Muenster, Stefan
    Weitz, David A.
    MacKintosh, Frederick C.
    [J]. SOFT MATTER, 2010, 6 (17) : 4120 - 4127
  • [6] Rheological, dielectric and diffusion analysis of mucin/carbopol matrices used in amperometric biosensors
    Capra, Raul H.
    Aruzzi, Ana M. B.
    Quinzani, Lidia M.
    Strumia, Miriam C.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2007, 124 (02) : 466 - 476
  • [7] Mucin/carbopol matrix to immobilize oxalate oxidase in a urine oxalate amperometric biosensor
    Capra, RH
    Strumia, M
    Vadgama, PM
    Baruzzi, AM
    [J]. ANALYTICA CHIMICA ACTA, 2005, 530 (01) : 49 - 54
  • [8] Alendronate-Conjugated Amphiphilic Hyperbranched Polymer Based on Boltorn H40 and Poly(ethylene glycol) for Bone-Targeted Drug Delivery
    Chen, Hongying
    Li, Guolin
    Chi, Huirong
    Wang, Dali
    Tu, Chunlai
    Pan, Lijie
    Zhu, Lijuan
    Qiu, Feng
    Guo, Fulin
    Zhu, Xinyuan
    [J]. BIOCONJUGATE CHEMISTRY, 2012, 23 (09) : 1915 - 1924
  • [9] Functionalized Amphiphilic Hyperbranched Polymers for Targeted Drug Delivery
    Chen, Si
    Zhang, Xian-Zheng
    Cheng, Si-Xue
    Zhuo, Ren-Xi
    Gu, Zhong-Wei
    [J]. BIOMACROMOLECULES, 2008, 9 (10) : 2578 - 2585
  • [10] Analysis and optimization of a hydrogel matrix for the development of a sandwich-type glucose biosensor
    Colombo, Lucas
    Maria Baruzzi, Ana
    Sebastian Garay, Fernando
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 211 : 125 - 130