Depth of interaction calibration for PET detectors with dual-ended readout by PSAPDs

被引:68
作者
Yang, Yongfeng [1 ]
Qi, Jinyi [1 ]
Wu, Yibao [1 ]
St James, Sara [1 ]
Farrell, Richard [2 ]
Dokhale, Purushottam A. [2 ]
Shah, Kanai S. [2 ]
Cherry, Simon R. [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[2] Radiat Monitoring Devices Inc, Watertown, MA 02172 USA
关键词
SMALL-ANIMAL PET; SENSITIVE AVALANCHE PHOTODIODES; RESOLUTION RESEARCH TOMOGRAPH; PERFORMANCE EVALUATION; MICROPET SCANNER; OF-INTERACTION; ECAT HRRT; DESIGN; SYSTEM;
D O I
10.1088/0031-9155/54/2/017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Many laboratories develop depth-encoding detectors to improve the trade-off between spatial resolution and sensitivity in positron emission tomography ( PET) scanners. One challenge in implementing these detectors is the need to calibrate the depth of interaction (DOI) response for the large numbers of detector elements in a scanner. In this work, we evaluate two different methods, a linear detector calibration and a linear crystal calibration, for determining DOI calibration parameters. Both methods can use measurements from any source distribution and location, or even the intrinsic lutetium oxyorthosilicate (LSO) background activity, and are therefore well suited for use in a depth-encoding PET scanner. The methods were evaluated by measuring detector and crystal DOI responses for all eight detectors in a prototype depth-encoding PET scanner. The detectors utilize dual-ended readout of LSO scintillator arrays with position-sensitive avalanche photodiodes (PSAPDs). The LSO arrays have 7 x 7 elements, with a crystal size of 0.92 x 0.92 x 20 mm(3) and pitch of 1.0 mm. The arrays are read out by two 8 x 8 mm(2) area PSAPDs placed at opposite ends of the arrays. DOI is measured by the ratio of the amplitude of the total energy signals measured by the two PSAPDs. Small variations were observed in the DOI responses of different crystals within an array as well as DOI responses for different arrays. A slightly nonlinear dependence of the DOI ratio on depth was observed and the nonlinearity was larger for the corner and edge crystals. The DOI calibration parameters were obtained from the DOI responses measured in a singles mode. The average error between the calibrated DOI and the known DOI was 0.8 mm if a linear detector DOI calibration was used and 0.5 mm if a linear crystal DOI calibration was used. A line source phantom and a hot rod phantom were scanned on the prototype PET scanner. DOI measurement significantly improved the image spatial resolution no matter which DOI calibration method was used. A linear crystal DOI calibration provided slightly better image spatial resolution compared with a linear detector DOI calibration.
引用
收藏
页码:433 / 445
页数:13
相关论文
共 24 条
  • [1] Evaluation of a prototype small animal PET detector with depth-of-interaction encoding
    Burr, KC
    Ivan, A
    Castleberry, DE
    LeBlanc, JW
    Shah, KS
    Farrell, R
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (04) : 1791 - 1798
  • [2] Performance measurements of a depth-encoding PET detector module based on position-sensitive avalanche photodiode read-out
    Dokhale, PA
    Silverman, RW
    Shah, KS
    Grazioso, R
    Farrell, R
    Glodo, J
    McClish, MA
    Entine, G
    Tran, VH
    Cherry, SR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (18) : 4293 - 4304
  • [3] Measurements of wavelength shifting (WLS) fibre readout for a highly multiplexed, depth-encoding PET detector
    Du, Huini
    Yang, Yongfeng
    Cherry, Simon R.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (09) : 2499 - 2514
  • [4] Eriksson L, 2002, IEEE T NUCL SCI, V49, P2085, DOI 10.1109/TNS.2002.803784
  • [5] Development of the LBNL positron emission mammography camera
    Huber, JS
    Choong, WS
    Wang, J
    Maltz, JS
    Qi, J
    Mandelli, E
    Moses, WW
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1650 - 1653
  • [6] 8-Layer DOI encoding of 3-dimensional crystal array
    Inadama, Naoko
    Murayama, Hideo
    Hamamoto, Manabu
    Tsuda, Tomoaki
    Ono, Yusuke
    Yamaya, Taiga
    Yoshida, Eiji
    Shibuya, Kengo
    Nishikido, Fumihiko
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2523 - 2528
  • [7] Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors
    Judenhofer, MS
    Pichler, BJ
    Cherry, SR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (01) : 29 - 44
  • [8] DESIGN STUDIES FOR A PET DETECTOR MODULE USING A PIN PHOTODIODE TO MEASURE DEPTH OF INTERACTION
    MOSES, WW
    DERENZO, SE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 1441 - 1445
  • [9] Design of a small animal PET imaging system with 1 microliter volume resolution
    Rouze, NC
    Schmand, M
    Siegel, S
    Hutchins, GD
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) : 757 - 763
  • [10] Investigation of depth-of-interaction by pulse shape discrimination in multicrystal detectors read out by avalanche photodiodes
    Saoudi, A
    Pepin, CM
    Dion, F
    Bentourkia, M
    Lecomte, R
    Andreaco, M
    Casey, M
    Nutt, R
    Dautet, H
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 462 - 467