Fast and selective determination of total protein in milk powder via titration of moving reaction boundary electrophoresis

被引:22
|
作者
Guo, Cheng-ye [1 ,2 ]
Wang, Hou-yu [1 ]
Liu, Xiao-Ping [1 ]
Fan, Liu-yin [1 ]
Zhang, Lei [2 ]
Cao, Cheng-xi [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Life Sci & Biotechnol, Lab Bioseparat & Analyt Biochem, State Key Lab Microbial Metab, Shanghai 200240, Peoples R China
[2] Shanghai Normal Univ, Sch Environm & Chem, Shanghai, Peoples R China
关键词
Infant milk powder; Moving reaction boundary; Total protein content; Titration; ACID-BASE TITRATION; DYE BINDING; CAPILLARY-ELECTROPHORESIS; AFFINITY-CHROMATOGRAPHY; SENSITIVE DETECTION; IMMUNOGLOBULIN-G; SPECTROSCOPY; BIOSENSOR; ELECTROMIGRATION; QUANTIFICATION;
D O I
10.1002/elps.201300007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper, moving reaction boundary titration (MRBT) was developed for rapid and accurate quantification of total protein in infant milk powder, from the concept of moving reaction boundary (MRB) electrophoresis. In the method, the MRB was formed by the hydroxide ions and the acidic residues of milk proteins immobilized via cross-linked polyacrylamide gel (PAG), an acid-base indicator was used to denote the boundary motion. As a proof of concept, we chose five brands of infant milk powders to study the feasibility of MRBT method. The calibration curve of MRB velocity versus logarithmic total protein content of infant milk powder sample was established based on the visual signal of MRB motion as a function of logarithmic milk protein content. Weak influence of nonprotein nitrogen (NPN) reagents (e.g., melamine and urea) on MRBT method was observed, due to the fact that MRB was formed with hydroxide ions and the acidic residues of captured milk proteins, rather than the alkaline residues or the NPN reagents added. The total protein contents in infant milk powder samples detected via the MRBT method were in good agreement with those achieved by the classic Kjeldahl method. In addition, the developed method had much faster measuring speed compared with the Kjeldahl method.
引用
收藏
页码:1343 / 1351
页数:9
相关论文
共 35 条
  • [1] Undergraduate laboratory experiment on determination of total protein content in milk powder by moving reaction boundary titration
    Luo, Anling
    Zheng, Youli
    Chen, Xinxin
    Cong, Fengsong
    BIOCHEMISTRY AND MOLECULAR BIOLOGY EDUCATION, 2018, 46 (06) : 644 - 651
  • [2] Determination of total protein content in soya-bean milk via visual moving reaction boundary titration
    Guo Chengye
    Wang Houyu
    Zhang Lei
    Fan Liuyin
    Cao Chengxi
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (11) : 1064 - 1070
  • [3] Determination of free acidic and alkaline residues of protein via moving reaction boundary titration in microdevice electrophoresis
    Wang, Hou-yu
    Li, Si
    Tang, Yun-yun
    Dong, Jing-yu
    Fan, Liu-yin
    Cao, Cheng-xi
    ANALYST, 2013, 138 (12) : 3544 - 3551
  • [4] Leverage principle of retardation signal in titration of double protein via chip moving reaction boundary electrophoresis
    Zhang, Liu-Xia
    Cao, Yi-Ren
    Xiao, Hua
    Liu, Xiao-Ping
    Liu, Shao-Rong
    Meng, Qing-Hua
    Fan, Liu-Yin
    Cao, Cheng-Xi
    BIOSENSORS & BIOELECTRONICS, 2016, 77 : 284 - 291
  • [5] A visual detection of protein content based on titration of moving reaction boundary electrophoresis
    Wang, Hou-Yu
    Guo, Cheng-Ye
    Guo, Chen-Gang
    Fan, Liu-Yin
    Zhang, Lei
    Cao, Cheng-Xi
    ANALYTICA CHIMICA ACTA, 2013, 774 : 92 - 99
  • [6] Retardation Signal for Fluorescent Determination of Total Protein Content via Rapid and Sensitive Chip Moving Reaction Boundary Electrophoretic Titration
    Wang, Houyu
    Shi, Yongting
    Yan, Jian
    Dong, Jingyu
    Li, Si
    Xiao, Hua
    Xie, Haiyang
    Fan, Liu-Yin
    Cao, Cheng-Xi
    ANALYTICAL CHEMISTRY, 2014, 86 (06) : 2888 - 2894
  • [7] Facile Counting of Ligands Capped on Nanoparticles via a Titration Chip of Moving Reaction Boundary Electrophoresis
    Zhang, Qiang
    Liu, Weiwen
    Khan, Muhammad Idrees
    Wang, Cunhuai
    Li, Guoqing
    Xiao, Hua
    Wang, Yuxing
    Cao, Chengxi
    ANALYTICAL CHEMISTRY, 2019, 91 (12) : 7500 - 7504
  • [8] Enzyme catalysis-electrophoresis titration for multiplex enzymatic assay via moving reaction boundary chip
    Zhong, Ran
    Xie, Haiyang
    Kong, Fanzhi
    Zhang, Qiang
    Jahan, Sharmin
    Xiao, Hua
    Fan, Liuyin
    Cao, Chengxi
    LAB ON A CHIP, 2016, 16 (18) : 3538 - 3547
  • [9] Continuous protein concentration via free-flow moving reaction boundary electrophoresis
    Kong, Fanzhi
    Zhang, Min
    Chen, Jingjing
    Fan, Liuyin
    Xiao, Hua
    Liu, Shaorong
    Cao, Chengxi
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1508 : 169 - 175
  • [10] Point of care testing (POCT) of cholesterol in blood serum via a moving reaction boundary electrophoresis titration chip
    Khan, Muhammad Idrees
    Zhang, Qiang
    Tian, Youli
    Saud, Shah
    Cao, Yiren
    Ren, Jicun
    Liu, Weiwen
    Cao, Chengxi
    ANALYTICAL METHODS, 2023, 15 (24) : 2971 - 2978