Experimental characterization of the 192 channel Clear-PEM frontend ASIC coupled to a multi-pixel APD readout of LYSO:Ce crystals

被引:25
作者
Albuquerque, Edgar [2 ]
Bexiga, Vasco [2 ]
Bugalho, Ricardo [1 ]
Carrico, Bruno [1 ]
Ferreira, Claudia S. [1 ]
Ferreira, Miguel [1 ]
Godinho, Joaquim [3 ]
Goncalves, Fernando [2 ]
Leong, Carlos [2 ]
Lousa, Pedro [3 ]
Machado, Pedro [2 ]
Moura, Rui [1 ]
Neves, Pedro [3 ]
Ortigao, Catarina [1 ]
Piedade, Fernando [3 ]
Pinheiro, Joao F. [1 ]
Rego, Joel [3 ]
Rivetti, Angelo [4 ]
Rodrigues, Pedro [1 ]
Silva, Jose C. [1 ]
Silva, Manuel M. [2 ]
Teixeira, Isabel C. [2 ,5 ]
Teixeira, Joao P. [2 ,5 ]
Trindade, Andreia [1 ]
Varela, Joao [1 ,5 ,6 ]
机构
[1] LIP, P-1000149 Lisbon, Portugal
[2] INESC ID, P-1000129 Lisbon, Portugal
[3] INOV, P-1000129 Lisbon, Portugal
[4] Ist Nazl Fis Nucl, I-10125 Turin, Italy
[5] IST, P-1049001 Lisbon, Portugal
[6] CERN, CH-1211 Geneva, Switzerland
关键词
PET; Avalanche photodiodes; ASIC; Frontend electronics; POSITRON EMISSION MAMMOGRAPHY; BREAST-CANCER; DETECTOR MODULES; QUALITY-CONTROL; TOMOGRAPHY; ARRAYS; DESIGN; SYSTEM; PERFORMANCE; DIAGNOSIS;
D O I
10.1016/j.nima.2008.10.005
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In the framework of the Clear-PEM project for the construction of a high-resolution scanner for breast cancer imaging, a very compact and dense frontend electronics system has been developed for readout of multi-pixel S8550 Hamamatsu APDs. The frontend electronics are instrumented with a mixed-signal Application-Specific Integrated Circuit (ASIC), which incorporates 192 low-noise charge pre-amplifiers, shapers, analog memory cells and digital control blocks. Pulses are continuously stored in memory cells at clock frequency. Channels above a common threshold voltage are readout for digitization by off-chip free-sampling ADCs. The ASIC has a size of 7.3 x 9.8 mm(2) and was implemented in a AMS 0.35 mu m CMOS technology. In this paper the experimental characterization of the Clear-PEM frontend ASIC, reading out multi-pixel APDs coupled to LYSC:Ce crystal matrices, is presented. The chips were mounted on a custom test board connected to six APD arrays and to the data acquisition system. Six 32-pixel LYSO:Ce crystal matrices coupled on both sides to APD arrays were readout by two test boards. All 384 channels were operational. The chip power consumption is 660 mW (3.4 mW per channel). A very stable behavior of the chip was observed, with an estimated ENC of 1200-1300e(-) at APD gain 100. The inter-channel noise dispersion and mean baseline variation is less than 8% and 0.5%, respectively. The spread in the gain between different channels is found to be 1.5%. Energy resolution of 16.5% at 511 keV and 12.8% at 662 keV has been measured. Timing measurements between the two APDs that readout the same crystal is extracted and compared with detailed Monte Carlo simulations. At 511 keV the measured single photon time RMS resolution is 1.30 ns, in very good agreement with the expected value of 1.34 ns. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:802 / 814
页数:13
相关论文
共 33 条
  • [1] Characterization and quality control of avalanche photodiode arrays for the Clear-PEM detector modules
    Abreu, Conceicao
    Amaral, Pedro
    Carrico, Bruno
    Ferreira, Miguel
    Luyten, Joan
    Moura, Rui
    Ortigao, Catarina
    Rato, Pedro
    Varela, Joao
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01) : 19 - 22
  • [2] Design and evaluation of the Clear-PEM scanner for positron emission mammography
    Abreu, MC
    Aguiar, JD
    Almeida, FG
    Almeida, P
    Bento, P
    Carrico, B
    Ferreira, M
    Ferreira, NC
    Gonçalves, F
    Leong, C
    Lopes, F
    Lousa, P
    Martins, MV
    Matela, N
    Mendes, PR
    Moura, R
    Nobre, J
    Oliveira, N
    Ortigao, C
    Peralta, L
    Pereira, R
    Rego, J
    Ribeiro, R
    Rodrigues, P
    Sampaio, J
    Santos, AI
    Silva, L
    Silva, JC
    Sousa, P
    Teixeira, IC
    Teixeira, JP
    Trindade, A
    Varela, J
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 71 - 77
  • [3] ABREU MC, 2005, 2005 IEEE NUCL SCI S, P2785
  • [4] ALBUQUERQUE E, 2008, 2008 IEEE NUCL SCI S
  • [5] The Clear-PEM electronics system
    Albuquerque, Edgar
    Bento, Pedro
    Leong, Carlos
    Goncalves, Fernando
    Nobre, Joao
    Rego, Joel
    Relvas, Paulo
    Lousa, Pedro
    Rodrigues, Pedro
    Teixeira, Isabel C.
    Teixeira, Joao P.
    Silva, Luis
    Silva, M. Medeiros
    Trindade, Andreia
    Varela, Joao
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2704 - 2711
  • [6] Performance and quality control of Clear-PEM detector modules
    Amaral, Pedro
    Carrico, Bruno
    Ferreira, Miguel
    Moura, Rui
    Ortigao, Catarina
    Rodrigues, Pedro
    Da Silva, Jose C.
    Trindade, Andreia
    Varela, Joao
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02) : 1123 - 1126
  • [7] Performance simulation studies of the clear-PEM DAQ/trigger system
    Bento, Pedro
    Goncalves, Fernando
    Leong, Carlos
    Lousa, Pedro
    Nobre, Joao
    Rego, Joel
    Relvas, Paulo
    Rodrigues, Pedro
    Silva, Jose C.
    Silva, Luis
    Teixeira, Isabel C.
    Teixeira, Joao P.
    Trindade, Andreia
    Varela, Joao
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (04) : 2102 - 2111
  • [8] BEXIGA V, 2008, 2008 IEEE NUCL SCI S
  • [9] BRIGLJEVIC V, 2003, 9 WORKSH EL LHC EXP
  • [10] BUSSON P, 1999, 1999020 CMS COLL