Evaluation of Feasibility and Image Quality of 68Ga-DOTATOC Positron Emission Tomography/Magnetic Resonance in Comparison With Positron Emission Tomography/Computed Tomography in Patients With Neuroendocrine Tumors
被引:48
作者:
Gaertner, Florian C.
[1
]
Beer, Ambros J.
[1
]
Souvatzoglou, Michael
[1
]
Eiber, Matthias
[2
]
Fuerst, Sebastian
[1
]
Ziegler, Sybille I.
[1
]
Brohl, Florian
[1
]
Schwaiger, Markus
[1
]
Scheidhauer, Klemens
[1
]
机构:
[1] TUM, Klinikum Rechts Isar, Dept Nucl Med, D-81675 Munich, Germany
[2] TUM, Klinikum Rechts Isar, Dept Radiol, D-81675 Munich, Germany
关键词:
hybrid imaging;
PET/CT;
PET/MR;
Ga-68-DOTATOC;
neuroendocrine tumors;
WHOLE-BODY PET/MRI;
STEREOTACTIC RADIOTHERAPY;
ATTENUATION CORRECTION;
PET;
CT;
MR;
SCANNER;
D O I:
10.1097/RLI.0b013e31828234d0
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Objectives: The primary aims of this study were to evaluate the feasibility of simultaneous (68)(DOTA(0)-Phe(1)-Tyr(3)) octreotide positron emission tomography (PET)/magnetic resonance (MR) acquisition on a fully integrated PET/MR scanner in patients and to compare the quality of PET images acquired with a PET/MR device with those acquired with a PET/computed tomography (CT) scanner. Patients and Methods: Sequential PET/CT and PET/MR imaging was performed in 24 patients with neuroendocrine tumors using a single-injection/dual-imaging protocol. After intravenous injection of Ga-68-DOTATOC (mean, 120 MBq), PET/CT imaging including low-dose CT was performed at a mean time of 17 minutes post injection, and subsequently, PET/MR imaging including a Dixon sequence for attenuation correction was started at a mean time of 82 minutes post injection. The PET/CT and PET/MR images were analyzed visually using a 4-point scale for quality, coregistration, anatomical correlation, and lesion conspicuity. The standardized uptake value of background organs and focal lesions was measured and compared between the PET/CT and PET/MR acquisitions. Results: Ga-68-DOTATOC PET acquired on the PET/MR delivered images with a good diagnostic quality (average visual rating PET/CT, 2.83; PET/MR, 2.08; P < 0.01). The standardized uptake value of focal lesions did not differ between the PET/CT and PET/MR acquisitions (P > 0.3) and correlated in a linear fashion (correlation coefficient rho = 0.90). Lesion conspicuity was slightly, but significantly, higher on the PET/CT acquisitions (PET/CT, 2.71; PET/MR, 2.62; P = 0.01). Positron emission tomography/MR detected 153 of 157 lesions identified by PET/CT; however, there was no difference in sensitivity on a patient basis or organ system basis. Anatomical correlates for focal PET lesions could significantly more often be delineated using MR Dixon images compared with low-dose CT (average visual rating PET/CT, 1.78; PET/MR, 2.30; P < 0.01). Coregistration of functional and morphological data was better on PET/MR compared with PET/CT, which, however, did not reach significance (average visual rating PET/CT, 2.17; PET/MR, 2.46; P = 0.10). Conclusions: Ga-68-DOTATOC PET/MR imaging is feasible in patients, with good image quality, and detectability of focal PET lesions was equivalent to PET/CT on a patient basis and organ system basis. Now, the clinical value of Ga-68-DOTATOC PET/MR with additional diagnostic MR protocols has to be evaluated against PET/CT with multiphase contrast-enhanced CT protocols in future studies.