Evaluation of Feasibility and Image Quality of 68Ga-DOTATOC Positron Emission Tomography/Magnetic Resonance in Comparison With Positron Emission Tomography/Computed Tomography in Patients With Neuroendocrine Tumors

被引:48
作者
Gaertner, Florian C. [1 ]
Beer, Ambros J. [1 ]
Souvatzoglou, Michael [1 ]
Eiber, Matthias [2 ]
Fuerst, Sebastian [1 ]
Ziegler, Sybille I. [1 ]
Brohl, Florian [1 ]
Schwaiger, Markus [1 ]
Scheidhauer, Klemens [1 ]
机构
[1] TUM, Klinikum Rechts Isar, Dept Nucl Med, D-81675 Munich, Germany
[2] TUM, Klinikum Rechts Isar, Dept Radiol, D-81675 Munich, Germany
关键词
hybrid imaging; PET/CT; PET/MR; Ga-68-DOTATOC; neuroendocrine tumors; WHOLE-BODY PET/MRI; STEREOTACTIC RADIOTHERAPY; ATTENUATION CORRECTION; PET; CT; MR; SCANNER;
D O I
10.1097/RLI.0b013e31828234d0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The primary aims of this study were to evaluate the feasibility of simultaneous (68)(DOTA(0)-Phe(1)-Tyr(3)) octreotide positron emission tomography (PET)/magnetic resonance (MR) acquisition on a fully integrated PET/MR scanner in patients and to compare the quality of PET images acquired with a PET/MR device with those acquired with a PET/computed tomography (CT) scanner. Patients and Methods: Sequential PET/CT and PET/MR imaging was performed in 24 patients with neuroendocrine tumors using a single-injection/dual-imaging protocol. After intravenous injection of Ga-68-DOTATOC (mean, 120 MBq), PET/CT imaging including low-dose CT was performed at a mean time of 17 minutes post injection, and subsequently, PET/MR imaging including a Dixon sequence for attenuation correction was started at a mean time of 82 minutes post injection. The PET/CT and PET/MR images were analyzed visually using a 4-point scale for quality, coregistration, anatomical correlation, and lesion conspicuity. The standardized uptake value of background organs and focal lesions was measured and compared between the PET/CT and PET/MR acquisitions. Results: Ga-68-DOTATOC PET acquired on the PET/MR delivered images with a good diagnostic quality (average visual rating PET/CT, 2.83; PET/MR, 2.08; P < 0.01). The standardized uptake value of focal lesions did not differ between the PET/CT and PET/MR acquisitions (P > 0.3) and correlated in a linear fashion (correlation coefficient rho = 0.90). Lesion conspicuity was slightly, but significantly, higher on the PET/CT acquisitions (PET/CT, 2.71; PET/MR, 2.62; P = 0.01). Positron emission tomography/MR detected 153 of 157 lesions identified by PET/CT; however, there was no difference in sensitivity on a patient basis or organ system basis. Anatomical correlates for focal PET lesions could significantly more often be delineated using MR Dixon images compared with low-dose CT (average visual rating PET/CT, 1.78; PET/MR, 2.30; P < 0.01). Coregistration of functional and morphological data was better on PET/MR compared with PET/CT, which, however, did not reach significance (average visual rating PET/CT, 2.17; PET/MR, 2.46; P = 0.10). Conclusions: Ga-68-DOTATOC PET/MR imaging is feasible in patients, with good image quality, and detectability of focal PET lesions was equivalent to PET/CT on a patient basis and organ system basis. Now, the clinical value of Ga-68-DOTATOC PET/MR with additional diagnostic MR protocols has to be evaluated against PET/CT with multiphase contrast-enhanced CT protocols in future studies.
引用
收藏
页码:263 / 272
页数:10
相关论文
共 26 条
[21]   Sliding multislice MRI for abdominal staging of patients with pelvic malignancies: A pilot study [J].
Sommer, Gregor ;
Schaefer, Arnd-Oliver ;
Baumann, Tobias ;
Ludwig, Ute A. ;
Fautz, Hans-Peter .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (03) :666-672
[22]   The Role of 68Ga-DOTATATE PET in Patients with Neuroendocrine Tumors and Negative or Equivocal Findings on 111In-DTPA-Octreotide Scintigraphy [J].
Srirajaskanthan, Rajaventhan ;
Kayani, Irfan ;
Quigley, Anne Marie ;
Soh, Jade ;
Caplin, Martyn E. ;
Bomanji, Jamshed .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (06) :875-882
[23]   Detection Rate, Location, and Size of Pulmonary Nodules in Trimodality PET/CT-MR Comparison of Low-Dose CT and Dixon-Based MR Imaging [J].
Stolzmann, Paul ;
Veit-Haibach, Patrick ;
Chuck, Natalie ;
Rossi, Cristina ;
Frauenfelder, Thomas ;
Alkadhi, Hatem ;
von Schulthess, Gustav ;
Boss, Andreas .
INVESTIGATIVE RADIOLOGY, 2013, 48 (05) :241-246
[24]   Procedure guidelines for PET/CT tumour imaging with 68Ga-DOTA-conjugated peptides: 68Ga-DOTA-TOC, 68Ga-DOTA-NOC, 68Ga-DOTA-TATE [J].
Virgolini, Irene ;
Ambrosini, Valentina ;
Bomanji, Jamshed B. ;
Baum, Richard P. ;
Fanti, Stefano ;
Gabriel, Michael ;
Papathanasiou, Nikolaos D. ;
Pepe, Giovanna ;
Oyen, Wim ;
De Cristoforo, Clemens ;
Chiti, Arturo .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (10) :2004-2010
[25]   Comparison of lesion detection and quantitation of tracer uptake between PET from a simultaneously acquiring whole-body PET/MR hybrid scanner and PET from PET/CT [J].
Wiesmueller, Marco ;
Quick, Harald H. ;
Navalpakkam, Bharath ;
Lell, Michael M. ;
Uder, Michael ;
Ritt, Philipp ;
Schmidt, Daniela ;
Beck, Michael ;
Kuwert, Torsten ;
von Gall, Carl C. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (01) :12-21
[26]   A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals [J].
Ziegler, SI ;
Pichler, BJ ;
Boening, G ;
Rafecas, M ;
Pimpl, W ;
Lorenz, E ;
Schmitz, N ;
Schwaiger, M .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (02) :136-143