A simple and efficient method for evaluating air-cleaning performance against airborne allergen particles

被引:7
作者
Kim, Hak-Joon [1 ]
Han, Bangwoo [1 ]
Kim, Yong-Jin [1 ]
Jeong, Choon-Soo [2 ]
Lee, Sung-Hwa [3 ]
机构
[1] Korea Inst Machinery & Mat, Environm & Energy Syst Res Div, Taejon 305343, South Korea
[2] Univ Ulsan, Sch Biol Sci, Ulsan 389749, South Korea
[3] LG Elect, Digital Appliance Co Res Lab, Seoul 153802, South Korea
关键词
Allergen; Airborne particles; ELISA; Optical particle counter; Clean-air delivery rate; Removal efficiency; INDOOR ALLERGENS; CAT ALLERGEN; EXPOSURE; DUST; REMOVAL; FILTRATION; CLEANERS; ASTHMA; HOMES;
D O I
10.1016/j.buildenv.2012.11.002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Size- and time-dependent aerodynamic behaviors of airborne allergen particles were evaluated in a 30-m(3) chamber, both with and without the operation of air-cleaning devices: a dehumidifier and an air conditioner. In-situ real-time measurements were taken using an optical particle counter. Removal efficiencies obtained from the counter, based on particle number and volumetric concentrations, were compared to values from the conventional ELISA method, which is time-consuming and requires off-line measurements. The log of clean-air delivery rates (CADR) was linearly proportional to the log of particle size. When a dehumidifier and an air conditioner were used, CADRs against airborne allergen particles increased by 4 and 7 times, respectively, compared with conditions without air-cleaning devices. The settlement of the particles smaller than 1 gm was hardly affected by gravity, but concentrations of these particles decreased to nearly 50 and 30% of the initial concentrations with the operation of a dehumidifier and of an air conditioner, respectively. Moreover, the concentration of particles with a peak size of about 5.7-mu m decreased to 9 and 0.3% of the initial value after only 30 min of operation of a dehumidifier and of an air conditioner, respectively. Comparing removal performance results between analyses that used a particle counter and the ELISA method, our new simple test method, which used an optical counter and was based on total volume concentrations, could easily predict the removal efficiency of airborne allergen particles, and the results were consistent with those obtained using the ELISA method. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:272 / 279
页数:8
相关论文
共 25 条
  • [1] Effect of an Air Cleaner with Electrostatic Filter on the Removal of Airborne House Dust Mite Allergens
    Agrawal, Santosh Rani
    Kim, Hak-Joon
    Lee, Yong Won
    Sohn, Jung-Ho
    Lee, Jae Hyun
    Kim, Yong-Jin
    Lee, Sung-Hwa
    Hong, Chein-Soo
    Park, Jung-Won
    [J]. YONSEI MEDICAL JOURNAL, 2010, 51 (06) : 918 - 923
  • [2] AHAM AASA, 2006, METH MEAS PERF PORT
  • [3] Distribution, aerodynamic characteristics, and removal of the major cat allergen Fel d 1 in British homes
    Custovic, A
    Simpson, A
    Pahdi, H
    Green, RM
    Chapman, MD
    Woodcock, A
    [J]. THORAX, 1998, 53 (01) : 33 - 38
  • [4] Exposure to house dust mite allergens and the clinical activity of asthma
    Custovic, A
    Taggart, SCO
    Francis, HC
    Chapman, MD
    Woodcock, A
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1996, 98 (01) : 64 - 72
  • [5] Mite allergen (Der p 1) is not only carried on mite feces
    De Lucca, S
    Sporik, R
    O'Meara, T
    Tovey, ER
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1999, 103 (01) : 174 - 175
  • [6] Improving indoor environments: Reducing allergen exposures
    Eggleston, PA
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2005, 116 (01) : 122 - 126
  • [7] Eggleston PA, 2001, J ALLERGY CLIN IMMUN, V107, pS403, DOI 10.1067/mai.2001.113673
  • [8] Clinical effects of air filters in homes of asthmatic adults sensitized and exposed to pet allergens
    Francis, H
    Fletcher, G
    Anthony, C
    Pickering, C
    Oldham, L
    Hadley, E
    Custovic, A
    Niven, R
    [J]. CLINICAL AND EXPERIMENTAL ALLERGY, 2003, 33 (01) : 101 - 105
  • [9] SENSITIZATION AND EXPOSURE TO INDOOR ALLERGENS AS RISK-FACTORS FOR ASTHMA AMONG PATIENTS PRESENTING TO HOSPITAL
    GELBER, LE
    SELTZER, LH
    BOUZOUKIS, JK
    POLLART, SM
    CHAPMAN, MD
    PLATTSMILLS, TAE
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (03): : 573 - 578
  • [10] Air filtration units in homes with cats: can they reduce personal exposure to cat allergen?
    Gore, RB
    Bishop, S
    Durrell, B
    Curbishley, L
    Woodcock, A
    Custovic, A
    [J]. CLINICAL AND EXPERIMENTAL ALLERGY, 2003, 33 (06) : 765 - 769