Acute thrombus formation on phosphorilcholine surface modified flow diverters

被引:53
作者
Marosfoi, Miklos [1 ]
Clarencon, Frederic [2 ]
Langan, Erin T. [1 ]
King, Robert M. [1 ]
Brooks, Olivia W. [1 ]
Tamura, Takamisu [1 ]
Wainwright, John M. [3 ]
Gounis, Matthew J. [1 ]
Vedantham, Srinivasan [4 ]
Puri, Ajit S. [1 ]
机构
[1] Univ Massachusetts, Sch Med, Dept Radiol, New England Ctr Stroke Res, Worcester, MA USA
[2] Hop La Pitie Salpetriere, Dept Intervent Neuroradiol, Paris, France
[3] Medtron Neurovasc, Res & Dev, Irvine, CA USA
[4] Univ Arizona, Banner Univ Med Ctr, Dept Med Imaging, Tucson, AZ USA
关键词
optical coherence tomography; flow diverters; intracranial aneurysms; dual antiplatelet therapy; PIPELINE EMBOLIZATION DEVICE; OPTICAL COHERENCE TOMOGRAPHY; INTRACRANIAL ANEURYSMS; RABBIT MODEL; CLOPIDOGREL; COMPLICATIONS; ARTERY; APPOSITION; CONJUGATE; THERAPY;
D O I
10.1136/neurintsurg-2017-013175
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Purpose Thromboembolic complications remain a limitation of flow diverting stents. We hypothesize that phosphorilcholine surface modified flow diverters (Pipeline Flex with Shield Technology, sPED) would have less acute thrombus formation on the device surface compared with the classic Pipeline Embolization device (cPED). Methods Elastase-induced aneurysms were created in 40 rabbits and randomly assigned to receive cPED or sPED devices with and without dual antiplatelet therapy (DAPT) (four groups, n=10/group). Angioplasty was performed to enhance apposition and create intimal injury for a pro-thrombotic environment. Both before and after angioplasty, the flow diverter was imaged with intravascular optical coherence tomography. The outcome measure was the number of predefined segments along the implant relative to the location of the aneurysm with a minimum of 0 (no clot formation) and maximum of 3 (all segments with thrombus). Clot formation over the device at ostia of branch arteries was assessed as either present or absent. Results Following angioplasty, the number of flow diverter segments with clots was significantly associated with the flow diverter (p<0.0001), but not with DAPT (p=0.3872) or aneurysm neck size (p=0.8555). The incidence rate for clots with cPED was 1.72 times more than with sPED. The clots on the flow diverter at the location corresponding to side branch ostia was significantly lower with sPED than with cPED (OR 0.180; 95%CI 0.044 to 0.734; p=0.0168), but was not associated with DAPT (p=0.3198). Conclusion In the rabbit model, phosphorilcholine surface modified flow diverters are associated with less thrombus formation on the surface of the device.
引用
收藏
页码:406 / 410
页数:5
相关论文
共 28 条
[1]   Last-Recorded P2Y12 Reaction Units Value Is Strongly Associated with Thromboembolic and Hemorrhagic Complications Occurring Up to 6 Months after Treatment in Patients with Cerebral Aneurysms Treated with the Pipeline Embolization Device [J].
Almandoz, J. E. Delgado ;
Crandall, B. M. ;
Scholz, J. M. ;
Fease, J. L. ;
Anderson, R. E. ;
Kadkhodayan, Y. ;
Tubman, D. E. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (01) :128-135
[2]   Pre-procedure P2Y12 reaction units value predicts perioperative thromboembolic and hemorrhagic complications in patients with cerebral aneurysms treated with the Pipeline Embolization Device [J].
Almandoz, Josser E. Delgado ;
Crandall, Benjamin M. ;
Scholz, Jill M. ;
Fease, Jennifer L. ;
Anderson, Ruth E. ;
Kadkhodayan, Yasha ;
Tubman, David E. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2013, 5 :III3-III10
[3]   Creation of saccular aneurysms in the rabbit: A model suitable for testing endovascular devices [J].
Altes, TA ;
Cloft, HJ ;
Short, JG ;
DeGast, A ;
Do, HM ;
Helm, GA ;
Kallmes, DF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :349-354
[4]   Long-Term Clinical and Angiographic Outcomes Following Pipeline Embolization Device Treatment of Complex Internal Carotid Artery Aneurysms: Five-Year Results of the Pipeline for Uncoilable or Failed Aneurysms Trial [J].
Becske, Tibor ;
Brinjikji, Waleed ;
Potts, Matthew B. ;
Kallmes, David F. ;
Shapiro, Maksim ;
Moran, Christopher J. ;
Levy, Elad I. ;
McDougall, Cameron G. ;
Szikora, Istvan ;
Lanzino, Giuseppe ;
Woo, Henry H. ;
Lopes, Demetrius K. ;
Siddiqui, Adnan H. ;
Albuquerque, Felipe C. ;
Fiorella, David J. ;
Saatci, Isil ;
Cekirge, Saruhan H. ;
Berez, Aaron L. ;
Cher, Daniel J. ;
Berentei, Zsolt ;
Marosfoi, Miklos ;
Nelson, Peter K. .
NEUROSURGERY, 2017, 80 (01) :40-48
[5]   Intracoronary Optical Coherence Tomography: A Comprehensive Review Clinical and Research Applications [J].
Bezerra, Hiram G. ;
Costa, Marco A. ;
Guagliumi, Giulio ;
Rollins, Andrew M. ;
Simon, Daniel I. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (11) :1035-1046
[6]   Silent ischemic events after Pipeline embolization device: a prospective evaluation with MR diffusion-weighted imaging [J].
Brasiliense, Leonardo B. C. ;
Stanley, Morgan A. ;
Grewal, Sanjeet S. ;
Cloft, Harry J. ;
Sauvageau, Eric ;
Lanzino, Giuseppe ;
Miller, David ;
Kallmes, David F. ;
Hanel, Ricardo .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (11) :1136-1139
[7]   Risk Factors for Ischemic Complications following Pipeline Embolization Device Treatment of Intracranial Aneurysms: Results from the IntrePED Study [J].
Brinjikji, W. ;
Lanzino, G. ;
Cloft, H. J. ;
Siddiqui, A. H. ;
Boccardi, E. ;
Cekirge, S. ;
Fiorella, D. ;
Hanel, R. ;
Jabbour, P. ;
Levy, E. ;
Lopes, D. ;
Lylyk, P. ;
Szikora, I. ;
Kallmes, D. F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (09) :1673-1678
[8]   Treatment of Complex Intracranial Aneurysms Using Flow-Diverting Silk® Stents An Analysis of 32 Consecutive Patients [J].
Buyukkaya, Ramazan ;
Kocaeli, Hasan ;
Yildirim, Nalan ;
Cebeci, Hakan ;
Erdogan, Cuneyt ;
Hakyemez, Bahattin .
INTERVENTIONAL NEURORADIOLOGY, 2014, 20 (06) :729-735
[9]   Bedside Monitoring to Adjust Antiplatelet Therapy for Coronary Stenting [J].
Collet, Jean-Philippe ;
Cuisset, Thomas ;
Range, Gregoire ;
Cayla, Guillaume ;
Elhadad, Simon ;
Pouillot, Christophe ;
Henry, Patrick ;
Motreff, Pascal ;
Carrie, Didier ;
Boueri, Ziad ;
Belle, Loic ;
Van Belle, Eric ;
Rousseau, Helene ;
Aubry, Pierre ;
Monsegu, Jacques ;
Sabouret, Pierre ;
O'Connor, Stephen A. ;
Abtan, Jeremie ;
Kerneis, Mathieu ;
Saint-Etienne, Christophe ;
Barthelemy, Olivier ;
Beygui, Farzin ;
Silvain, Johanne ;
Vicaut, Eric ;
Montalescot, Gilles .
NEW ENGLAND JOURNAL OF MEDICINE, 2012, 367 (22) :2100-2109
[10]   P2Y12 Reaction Units: Effect on Hemorrhagic and Thromboembolic Complications in Patients With Cerebral Aneurysms Treated With the Pipeline Embolization Device [J].
Daou, Badih ;
Starke, Robert M. ;
Chalouhi, Nohra ;
Barros, Guilherme ;
Tjoumakaris, Stavropoula ;
Rosenwasser, Robert H. ;
Jabbour, Pascal .
NEUROSURGERY, 2016, 78 (01) :27-33