Marginal Adaptation of All-Ceramic Crowns on Implant Abutments

被引:30
作者
Att, Wael [1 ,2 ]
Hoischen, Tomas
Gerds, Thomas [3 ]
Strub, Joerg Rudolf
机构
[1] Univ Freiburg, Sch Dent, Dept Prosthodont, D-79106 Freiburg, Germany
[2] Univ Calif Los Angeles, Sch Dent, Weintraub Ctr Reconstruct Biotechnol, Los Angeles, CA 90024 USA
[3] Univ Freiburg, Inst Med Biometr & Med Informat, D-79106 Freiburg, Germany
关键词
all-ceramic crowns; alumina; implant abutments; marginal accuracy; mastication simulator; zirconia;
D O I
10.1111/j.1708-8208.2007.00079.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Studies focusing on the marginal accuracy of all-ceramic crowns on implant abutments are in short supply. Purpose: This study evaluated the marginal accuracy of all-ceramic crowns on different implant abutments. Materials and Methods: Ninety-six standardized maxillary central incisor crowns (48 alumina and 48 zirconia) were fabricated for each of the six test groups (n = 16) (Ti1, titanium abutments-alumina crowns; Ti2, titanium abutments-zirconia crowns; Al1, alumina abutments-alumina crowns; Al2, alumina abutments-zirconia crowns; Zr1, zirconia abutments-alumina crowns; Zr2, zirconia abutments-zirconia crowns). The crowns were adhesively luted using a resin luting agent. The marginal gaps were examined on epoxy replicas before and after luting as well as after masticatory simulation at 200x magnification. Results: The geometrical mean (95% confidence limits) marginal gap values before cementation, after cementation, and after masticatory simulation were group Ti1: 39(37-42), 57(53-62), and 49(46-53); group Ti2: 43(40-47), 71(67-76), and 64(59-69); group Al1: 57(54-61), 87(85-90), and 67(65-69); group Al2: 66(63-69), 96(90-101), and 75(72-78); group Zr1: 54(51-57), 79(76-82), and 65(63-67); and group Zr2: 64(60-68), 85(80-91), and 75(70-81). The comparison between non-cemented and cemented stages in each group demonstrated a significant increase in the marginal gap values after cementation in all groups (p < .001), while the comparison between cemented and aged stages in each group showed a significant decrease in the marginal gap values in groups Al1, Al2, and Zr1 (p < .0001). This reduction was not significant for groups Ti1, Ti2, and Zr2 (p > .05). Conclusion: The marginal accuracy of all tested restorations meets the requirements for clinical acceptance.
引用
收藏
页码:218 / 225
页数:8
相关论文
共 40 条
[1]  
Andersson B, 2003, INT J PROSTHODONT, V16, P640
[2]  
Andersson B, 2001, INT J PROSTHODONT, V14, P432
[3]   Fracture resistance of single-tooth implant-supported all-ceramic restorations after exposure to the artificial mouth [J].
Att, W ;
Kurun, S ;
Gerds, T ;
Strub, JR .
JOURNAL OF ORAL REHABILITATION, 2006, 33 (05) :380-386
[4]   Fracture resistance of single-tooth implant-supported all-ceramic restorations: An in vitro study [J].
Att, W ;
Kurun, S ;
Gerds, T ;
Strub, JR .
JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (02) :111-116
[5]  
Bates J F, 1976, J Oral Rehabil, V3, P57, DOI 10.1111/j.1365-2842.1976.tb00929.x
[6]  
Besimo C, 1996, INT J PROSTHODONT, V9, P87
[7]   Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations [J].
Bindl, A ;
Mörmann, WH .
JOURNAL OF ORAL REHABILITATION, 2005, 32 (06) :441-447
[8]   Resin-ceramic bonding: a review of the literature [J].
Blatz, MB ;
Sadan, A ;
Kern, M .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 89 (03) :268-274
[9]  
Buchalla W, 2000, OPER DENT, V25, P482
[10]   MECHANICAL-PROPERTIES AND SHORT-TERM INVIVO EVALUATION OF YTTRIUM-OXIDE-PARTIALLY-STABILIZED ZIRCONIA [J].
CHRISTEL, P ;
MEUNIER, A ;
HELLER, M ;
TORRE, JP ;
PEILLE, CN .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1989, 23 (01) :45-61