Simultaneous dual-energy X-ray stereo imaging

被引:7
|
作者
Mokso, Rajmund [1 ]
Oberta, Peter [2 ,3 ]
机构
[1] Paul Scherrer Inst, Swiss Light Source, CH-5232 Villigen, Switzerland
[2] Acad Sci Czech Republ, Inst Phys, Vvi, Prague 8, Czech Republic
[3] Rigaku Innovat Technol Europe Sro, Prague 4, Czech Republic
来源
JOURNAL OF SYNCHROTRON RADIATION | 2015年 / 22卷
关键词
optics; crystals; imaging; dual-energy; SYNCHROTRON-RADIATION; CORONARY-ANGIOGRAPHY; RADIOGRAPHY;
D O I
10.1107/S1600577515006554
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Dual-energy or K-edge imaging is used to enhance contrast between two or more materials in an object and is routinely realised by acquiring two separate X-ray images each at different X-ray wavelength. On a broadband synchrotron source an imaging system to acquire the two images simultaneously was realised. The single-shot approach allows dual-energy and stereo imaging to be applied to dynamic systems. Using a Laue-Bragg crystal splitting scheme, the X-ray beam was split into two and the two beam branches could be easily tuned to either the same or to two different wavelengths. Due to the crystals' mutual position, the two beam branches intercept each other under a non-zero angle and create a stereoscopic setup.
引用
收藏
页码:1078 / 1082
页数:5
相关论文
共 50 条
  • [41] Dual-energy X-ray radiography for automatic high-Z material detection
    Chen, Gongyin
    Bennett, Gordon
    Perticone, David
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 261 (1-2) : 356 - 359
  • [42] Efficient material decomposition method for dual-energy X-ray cargo inspection system
    Lee, Donghyeon
    Lee, Jiseoc
    Min, Jonghwan
    Lee, Byungcheol
    Lee, Byeongno
    Oh, Kyungmin
    Kim, Jaehyun
    Cho, Seungryong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 884 : 105 - 112
  • [43] Dual energy phase contrast x-ray imaging with Talbot-Lau interferometer
    Kottler, Christian
    Revol, Vincent
    Kaufmann, Rolf
    Urban, Claus
    JOURNAL OF APPLIED PHYSICS, 2010, 108 (11)
  • [44] X-ray dual-energy calibration based on estimated spectral properties of the experimental system
    Hassler, U
    Garnero, L
    Rizo, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1699 - 1712
  • [45] Assessment of the possibilities of the dual-energy X-ray absorptiometry of multicomponent samples with variable content
    N. A. Antropov
    D. A. Karpov
    Yu. Yu. Kryuchkov
    Instruments and Experimental Techniques, 2012, 55 : 608 - 610
  • [46] Dual-energy x-ray absorptiometry as a measure of healing in fractures treated by intramedullary nailing
    Cattermole, HC
    Fordham, JN
    Muckle, DS
    Cunningham, JL
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (08) : 563 - 568
  • [47] Assessment of the possibilities of the dual-energy X-ray absorptiometry of multicomponent samples with variable content
    Antropov, N. A.
    Karpov, D. A.
    Kryuchkov, Yu Yu
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2012, 55 (05) : 608 - 610
  • [48] Dual-energy X-ray absorptiometry technical issues: The 2007 ISCD Official Positions
    Schousboe, John T.
    Vokes, Tamara
    Broy, Susan B.
    Ferrar, Lynne
    McKiernan, Fergus
    Roux, Christian
    Binkley, Neil
    JOURNAL OF CLINICAL DENSITOMETRY, 2008, 11 (01) : 92 - 108
  • [49] Application of a dual energy X-ray imaging method on breast specimen
    Koukou, V.
    Martini, N.
    Fountos, G.
    Michail, C.
    Bakas, A.
    Oikonomou, G.
    Kandarakis, I.
    Nikiforidis, G.
    RESULTS IN PHYSICS, 2017, 7 : 1634 - 1636
  • [50] A dual-energy x-ray absorptiometry artifact and potential pitfall - The nonremovable umbilical ring
    Bohdiewicz, PJ
    Khan, AM
    CLINICAL NUCLEAR MEDICINE, 2002, 27 (12) : 911 - 912