Simultaneous dual-energy X-ray stereo imaging

被引:7
|
作者
Mokso, Rajmund [1 ]
Oberta, Peter [2 ,3 ]
机构
[1] Paul Scherrer Inst, Swiss Light Source, CH-5232 Villigen, Switzerland
[2] Acad Sci Czech Republ, Inst Phys, Vvi, Prague 8, Czech Republic
[3] Rigaku Innovat Technol Europe Sro, Prague 4, Czech Republic
来源
JOURNAL OF SYNCHROTRON RADIATION | 2015年 / 22卷
关键词
optics; crystals; imaging; dual-energy; SYNCHROTRON-RADIATION; CORONARY-ANGIOGRAPHY; RADIOGRAPHY;
D O I
10.1107/S1600577515006554
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Dual-energy or K-edge imaging is used to enhance contrast between two or more materials in an object and is routinely realised by acquiring two separate X-ray images each at different X-ray wavelength. On a broadband synchrotron source an imaging system to acquire the two images simultaneously was realised. The single-shot approach allows dual-energy and stereo imaging to be applied to dynamic systems. Using a Laue-Bragg crystal splitting scheme, the X-ray beam was split into two and the two beam branches could be easily tuned to either the same or to two different wavelengths. Due to the crystals' mutual position, the two beam branches intercept each other under a non-zero angle and create a stereoscopic setup.
引用
收藏
页码:1078 / 1082
页数:5
相关论文
共 50 条
  • [21] Dual-energy X-ray CT with CdTe array and its extension
    Ohno, Y
    Torikoshi, M
    Tsunoo, T
    Hyodo, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2) : 72 - 77
  • [22] Dual-Energy X-Ray Dark-Field Material Decomposition
    Sellerer, Thorsten
    Mechlem, Korbinian
    Tang, Ruizhi
    Taphorn, Kirsten Alexandra
    Pfeiffer, Franz
    Herzen, Julia
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (03) : 974 - 985
  • [23] Rock porosity quantification by dual-energy X-ray computed microtomography
    Teles, A. P.
    Lima, I.
    Topes, R. T.
    MICRON, 2016, 83 : 72 - 78
  • [24] Adaptive noise reduction for dual-energy x-ray imaging based on spatial variations in beam attenuation
    Romadanov, Ivan
    Sattarivand, Mike
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24)
  • [25] A curve-based material recognition method in MeV dual-energy X-ray imaging system
    Chen, Zhi-Qiang
    Zhao, Tiao
    Li, Liang
    NUCLEAR SCIENCE AND TECHNIQUES, 2016, 27 (01)
  • [26] Linear modeling of single-shot dual-energy x-ray imaging using a sandwich detector
    Kim, J.
    Kim, D. W.
    Kim, S. H.
    Yun, S.
    Youn, H.
    Jeon, H.
    Kim, H. K.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [27] A curve-based material recognition method in MeV dual-energy X-ray imaging system
    Zhi-Qiang Chen
    Tiao Zhao
    Liang Li
    Nuclear Science and Techniques, 2016, 27 (01) : 173 - 180
  • [28] A curve-based material recognition method in MeV dual-energy X-ray imaging system
    Zhi-Qiang Chen
    Tiao Zhao
    Liang Li
    Nuclear Science and Techniques, 2016, 27
  • [29] Effective dose reduction in dual-energy flat panel X-ray imaging:: Technique and clinical evaluation
    Avinash, GB
    Jabri, KN
    Uppaluri, R
    Rader, A
    Fischbach, F
    Ricke, J
    Teichgräber, U
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 1048 - 1059
  • [30] APPLICATION OF A DUAL-ENERGY MONOCHROMATIC X-RAY CT ALGORITHM TO POLYCHROMATIC X-RAY CT: A FEASIBILITY STUDY
    Chang, S.
    Lee, H. K.
    Cho, G.