Simultaneous dual-energy X-ray stereo imaging

被引:7
|
作者
Mokso, Rajmund [1 ]
Oberta, Peter [2 ,3 ]
机构
[1] Paul Scherrer Inst, Swiss Light Source, CH-5232 Villigen, Switzerland
[2] Acad Sci Czech Republ, Inst Phys, Vvi, Prague 8, Czech Republic
[3] Rigaku Innovat Technol Europe Sro, Prague 4, Czech Republic
来源
JOURNAL OF SYNCHROTRON RADIATION | 2015年 / 22卷
关键词
optics; crystals; imaging; dual-energy; SYNCHROTRON-RADIATION; CORONARY-ANGIOGRAPHY; RADIOGRAPHY;
D O I
10.1107/S1600577515006554
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Dual-energy or K-edge imaging is used to enhance contrast between two or more materials in an object and is routinely realised by acquiring two separate X-ray images each at different X-ray wavelength. On a broadband synchrotron source an imaging system to acquire the two images simultaneously was realised. The single-shot approach allows dual-energy and stereo imaging to be applied to dynamic systems. Using a Laue-Bragg crystal splitting scheme, the X-ray beam was split into two and the two beam branches could be easily tuned to either the same or to two different wavelengths. Due to the crystals' mutual position, the two beam branches intercept each other under a non-zero angle and create a stereoscopic setup.
引用
收藏
页码:1078 / 1082
页数:5
相关论文
共 50 条
  • [1] Dual-energy X-ray imaging: benefits and limits
    Rebuffel, V.
    Dinten, J-M
    INSIGHT, 2007, 49 (10) : 589 - 594
  • [2] Dual-Energy X-ray Imaging by Simultaneous Integration and Campbelling Readout
    Roessl, Ewald
    Thran, Axel
    Martens, Gerhard
    Istel, Thomas
    Proksa, Roland
    Schlomka, Jens-Peter
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2112 - 2115
  • [3] Capabilities of Dual-Energy X-Ray Imaging in Medicine and Security
    Ryzhikov, Volodymyr D.
    Grinyov, Borys V.
    Opolonin, Oleksandr D.
    Galkin, Serhiy M.
    Lysetska, Olena K.
    Voronkin, Yevheniy F.
    Kostioukevitch, Serhiy A.
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS XIII, 2012, 8509
  • [4] Spectral and dual-energy X-ray imaging for medical applications
    Fredenberg, Erik
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 : 74 - 87
  • [5] Multiscale deformable registration for dual-energy x-ray imaging
    Gang, G. J.
    Varon, C. A.
    Kashani, H.
    Richard, S.
    Paul, N. S.
    Van Metter, R.
    Yorkston, J.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2009, 36 (02) : 351 - 363
  • [6] Robust Material Classification on Dual-Energy X-Ray Imaging Devices
    Cigla, Cevahir
    Kucukates, Busra
    Yalcin, Ozan
    Ak, Duygu Selin
    Isikoglu, Sukrucan Taylan
    ANOMALY DETECTION AND IMAGING WITH X-RAYS (ADIX) VII, 2022, 12104
  • [7] Preliminary demonstration of flexible dual-energy x-ray phase-contrast imaging
    Wang, Shenghao
    Zan, Guibin
    Wang, Qiuping
    Liu, Shijie
    OPTICAL ENGINEERING, 2019, 58 (11)
  • [8] Dual-Energy X-ray Medical Imaging with Inverse Compton Sources: A Simulation Study
    Paterno, Gianfranco
    Cardarelli, Paolo
    Gambaccini, Mauro
    Taibi, Angelo
    CRYSTALS, 2020, 10 (09): : 1 - 21
  • [9] Preliminary research on dual-energy X-ray phase-contrast imaging
    Han, Hua-Jie
    Wang, Sheng-Hao
    Gao, Kun
    Wang, Zhi-Li
    Zhang, Can
    Yang, Meng
    Zhang, Kai
    Zhu, Pei-Ping
    CHINESE PHYSICS C, 2016, 40 (04)
  • [10] Dual-energy computed tomography imaging with megavoltage and kilovoltage X-ray spectra
    Jadick, Giavanna
    Schlafly, Geneva
    La Riviere, Patrick J.
    JOURNAL OF MEDICAL IMAGING, 2024, 11 (02)