Evaluation of Falls Risk in Community-Dwelling Older Adults Using Body-Worn Sensors

被引:68
作者
Greene, Barry R. [1 ]
Doheny, Emer P. [1 ]
Walsh, Cathal [2 ]
Cunningham, Clodagh [4 ]
Crosby, Lisa [4 ]
Kenny, Rose A. [3 ,4 ]
机构
[1] Intel Labs, Leixlip, Kildare, Ireland
[2] Trinity Coll Dublin, Dept Stat, Dublin, Ireland
[3] Trinity Coll Dublin, Dept Med Gerontol, Dublin, Ireland
[4] St James Hosp, Falls & Blackout Unit, Dublin, Ireland
关键词
Falls risk estimation; Prospective study; 'Timed Up and Go' test; ELDERLY-PATIENTS; GO; BALANCE; PROBABILITY; MOBILITY; INDEX;
D O I
10.1159/000337259
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background: Falls are the most common cause of injury and hospitalization and one of the principal causes of death and disability in older adults worldwide. This study aimed to determine if a method based on body-worn sensor data can prospectively predict falls in community-dwelling older adults, and to compare its falls prediction performance to two standard methods on the same data set. Methods: Data were acquired using body-worn sensors, mounted on the left and right shanks, from 226 community-dwelling older adults (mean age 71.5 +/- 6.7 years, 164 female) to quantify gait and lower limb movement while performing the 'Timed Up and Go' (TUG) test in a geriatric research clinic. Participants were contacted by telephone 2 years following their initial assessment to determine if they had fallen. These outcome data were used to create statistical models to predict falls. Results: Results obtained through cross-validation yielded a mean classification accuracy of 79.69% (mean 95% CI: 77.09-82.34) in prospectively identifying participants that fell during the follow-up period. Results were significantly (p < 0.0001) more accurate than those obtained for falls risk estimation using two standard measures of falls risk (manually timed TUG and the Berg balance score, which yielded mean classification accuracies of 59.43% (95% CI: 58.07-60.84) and 64.30% (95% CI: 62.56-66.09), respectively). Conclusion: Results suggest that the quantification of movement during the TUG test using body-worn sensors could lead to a robust method for assessing future falls risk. Copyright (C) 2012 S. Karger AG, Basel
引用
收藏
页码:472 / 480
页数:9
相关论文
共 41 条
  • [1] [Anonymous], 2007, Global Report on Falls Prevention in Older Age
  • [2] [Anonymous], 2004, COMBINING PATTERN CL, DOI DOI 10.1002/0471660264
  • [3] [Anonymous], 2000, Pattern Classification
  • [4] BERG K, 1989, Physiotherapy Canada, V41, P304
  • [5] VALIDATION OF A COMBINED COMORBIDITY INDEX
    CHARLSON, M
    SZATROWSKI, TP
    PETERSON, J
    GOLD, J
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 1994, 47 (11) : 1245 - 1251
  • [6] Cockrell J.R., 2002, Principles and practice of geriatric psychiatry, P140, DOI DOI 10.1002/0470846410
  • [7] Development of a clinical measure of turning for older adults
    Dite, W
    Temple, VA
    [J]. AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2002, 81 (11) : 857 - 866
  • [8] Ferraris F., 1995, Sensors and Materials, V7, P311
  • [9] Systematic review of accuracy of screening instruments for predicting fall risk among independently living older adults
    Gates, Simon
    Smith, Lesley A.
    Fisher, Joanne D.
    Lamb, Sarah E.
    [J]. JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2008, 45 (08) : 1105 - 1116
  • [10] Investigation of fall-risk using a wearable device with accelerometers and rate gyroscopes
    Giansanti, Daniele
    [J]. PHYSIOLOGICAL MEASUREMENT, 2006, 27 (11) : 1081 - 1090