Dosimetric Comparison of Volumetric Modulated Arc Therapy, Step-And-Shoot, and Sliding Window IMRT for Prostate Cancer

被引:0
|
作者
Schnell, Erich [1 ]
Herman, Tania De La Fuente [1 ]
Young, Julie [1 ]
Hildebrand, Kim [1 ]
Algan, Ozer [1 ]
Syzek, Elizabeth [1 ]
Herman, Terence [1 ]
Ahmad, Salahuddin [1 ]
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Dept Radiat Oncol, Oklahoma City, OK 73104 USA
来源
MEDICAL PHYSICS | 2012年 / 1494卷
关键词
Prostate Cancer; Intensity Modulated Radiation Therapy; Volumetric Modulated Arc Therapy; Step and Shoot; Sliding Window; COMPLICATION PROBABILITY; BRACHYTHERAPY; IRRADIATION;
D O I
10.1063/1.4764589
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aims to evaluate treatment plans generated by Step-and-Shoot (SS), Sliding Window (SW) and Volumetric Modulated Arc Therapy (VMAT) in order to assess the differences in dose volume histograms of planning target volume (PTV) and organs at risk (OAR), conformity indices, radiobiological evaluations, and plan quality for prostate cancer cases. Six prostate cancer patients treated in our center were selected for this retrospective study. Treatment plans were generated with Eclipse version 8.9 using 10 MV photon beams. For VMAT, Varian Rapid Arc with 1 or 2 arcs, and for SS and SW IMRT, 7-9 fields were used. Each plan had three PTVs with prescription doses of 81, 59.4, and 45 Gy to prostate, to prostate and lymph nodes, and to pelvis, respectively. Doses to PTV and OAR and the conformal indices (COIN) were compared among three techniques. The equivalent uniform dose (EUD), tumor control probability (TCP) and normal tissue complication probability (NTCP) were calculated and compared. The mean doses to the PTV prostate on average were 83 Gy and the percent differences of mean dose among all techniques were below 0.28. For bladder and rectum, the percent differences of mean dose among all techniques were below 2.2. The COIN did not favour any particular delivery method over the other. The TCP was higher with SS and SW for four patients and higher with VMAT for two patients. The NTCP for the rectum was the lowest with VMAT in five out of the six patients. The results show similar target coverage in general.
引用
收藏
页码:23 / 26
页数:4
相关论文
共 50 条
  • [31] Dosimetric Comparison of Intensity-Modulated Radiotherapy and Volumetric Arc Therapy for Rectal Cancer
    Oskeroglu Kaplan, Sedenay
    Akboru, Halil
    Sarali, Yunus
    Altin, Suleyman
    Unsal, Mustafa
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2019, 34 (02): : 59 - 65
  • [32] A dosimetric comparison of volumetric modulated arc therapy (VMAT) and non-coplanar intensity modulated radiotherapy (IMRT) for nasal cavity and paranasal sinus cancer
    Jeong, Yuri
    Lee, Sang-wook
    Kwak, Jungwon
    Cho, Ilsung
    Yoon, Sang Min
    Kim, Jong Hoon
    Park, Jin-hong
    Choi, Eun Kyung
    Song, Si Yeol
    Kim, Young Seok
    Kim, Su Ssan
    Joo, Ji Hyeon
    Ahn, Seung Do
    RADIATION ONCOLOGY, 2014, 9
  • [33] Dosimetric comparison between step-shoot intensity-modulated radiotherapy and volumetric-modulated arc therapy for upper thoracic and cervical esophageal carcinoma
    Gao, Min
    Li, Qilin
    Ning, Zhonghua
    Gu, Wendong
    Huang, Jin
    Mu, Jinming
    Pei, Honglei
    MEDICAL DOSIMETRY, 2016, 41 (02) : 131 - 135
  • [34] A dosimetric comparison of volumetric modulated arc therapy (VMAT) and non-coplanar intensity modulated radiotherapy (IMRT) for nasal cavity and paranasal sinus cancer
    Yuri Jeong
    Sang-wook Lee
    Jungwon Kwak
    Ilsung Cho
    Sang Min Yoon
    Jong Hoon Kim
    Jin-hong Park
    Eun Kyung Choi
    Si Yeol Song
    Young Seok Kim
    Su Ssan Kim
    Ji Hyeon Joo
    Seung Do Ahn
    Radiation Oncology, 9
  • [35] Helical tomotherapy for head and neck squamous cell carcinoma: Dosimetric comparison with linear accelerator-based step-and-shoot IMRT
    Murthy, Vedang
    Master, Zubin
    Gupta, Tejpal
    Ghosh-Laskar, Sarbani
    Budrukkar, Ashwini
    Phurailatpam, Reenadevi
    Agarwal, Jaiprakash
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2010, 6 (02) : 194 - 198
  • [36] Dosimetric comparison of helical tomotherapy treatment and step-and-shoot intensity-modulated radiotherapy of retroperitoneal sarcoma
    Pezner, Richard D.
    Liu, An
    Han, Chunhui
    Chen, Yi-Jen
    Schultheiss, Timothy E.
    Wong, Jeffrey Y. C.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 (01) : 81 - 87
  • [37] Dosimetric comparison of volumetric-modulated arc therapy and helical tomotherapy for adjuvant treatment of bilateral breast cancer
    Phurailatpam, Reena
    Wadasadawala, Tabassum
    Chauhan, Kamalnayan
    Panda, Subhajit
    Sarin, Rajiv
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 36 - 44
  • [38] A study of segment weight optimization with the CMS XiO step-and-shoot IMRT technique for prostate cancer
    Prabhakar, Ramachandran
    Cramb, Jim
    Gehrke, Christopher
    Anderson, Justin
    Andrews, Judy
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (01): : 205 - 214
  • [39] A treatment planning study comparing tomotherapy, volumetric modulated arc therapy, Sliding Window and proton therapy for low-risk prostate carcinoma
    Sergiu Scobioala
    Christopher Kittel
    Nicolas Wissmann
    Uwe Haverkamp
    Mohammed Channaoui
    Omar Habibeh
    Khaled Elsayad
    Hans Theodor Eich
    Radiation Oncology, 11
  • [40] SmartArc-based volumetric modulated arc therapy for endometrial cancer: a dosimetric comparison with helical tomotherapy and intensity-modulated radiation therapy
    Ruijie Yang
    Junjie Wang
    Shouping Xu
    Hua Li
    BMC Cancer, 13