Dosimetric effects of intrafractional isocenter variation during deep inspiration breath-hold for breast cancer patients using surface-guided radiotherapy

被引:43
|
作者
Kugele, Malin [1 ,2 ]
Edvardsson, Anneli [2 ]
Berg, Lovisa [1 ]
Alkner, Sara [1 ]
Ljus, Carina Andersson [1 ]
Ceberg, Sofie [1 ,2 ]
机构
[1] Skane Univ Hosp, Dept Hematol Oncol & Radiat Phys, Lund, Sweden
[2] Lund Univ, Dept Clin Sci, Med Radiat Phys, Lund, Sweden
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2018年 / 19卷 / 01期
关键词
breath hold; intrafractional isocenter variation; optical surface scanning; treatment planning; RADIATION-THERAPY; HEART-DISEASE; RISK; WOMEN; REPRODUCIBILITY; MORTALITY; COHORT;
D O I
10.1002/acm2.12214
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to investigate potential dose reductions to the heart, left anterior descending coronary artery (LAD), and ipsilateral lung for left-sided breast cancer using visually guided deep inspiration breath-hold (DIBH) with the optical surface scanning system Catalyst (TM), and how these potential dosimetric benefits are affected by intrafractional motion in between breath holds. For both DIBH and free breathing (FB), treatment plans were created for 20 tangential and 20 locoregional left-sided breast cancer patients. During DIBH treatment, beam-on was triggered by a region of interest on the xiphoid process using a 3 mm gating window. Using a novel nonrigid algorithm, the Catalyst (TM) system allows for simultaneous real-time tracking of the isocenter position, which was used to calculate the intrafractional DIBH isocenter reproducibility. The 50% and 90% cumulative probabilities and maximum values of the intrafractional DIBH isocenter reproducibility were calculated and to obtain the dosimetric effect isocenter shifts corresponding to these values were performed in the treatment planning system. For both tangential and locoregional treatment, the dose to the heart, LAD and ipsilateral lung was significantly reduced for DIBH compared to FB. The intrafractional DIBH isocenter reproducibility was very good for the majority of the treatment sessions, with median values of approximately 1 mm in all three translational directions. However, for a few treatment sessions, intrafractional DIBH isocenter reproducibility of up to 5 mm was observed, which resulted in large dosimetric effects on the target volume and organs at risk. Hence, it is of importance to set tolerance levels on the intrafractional isocenter motion and not only perform DIBH based on the xiphoid process.
引用
收藏
页码:25 / 38
页数:14
相关论文
共 50 条
  • [21] Heart position variability during voluntary moderate deep inspiration breath-hold radiotherapy for breast cancer determined by repeat CBCT scans
    van Haaren, Paul
    Claassen-Janssen, Fiere
    van de Sande, Ingrid
    Boersma, Liesbeth
    van der Sangen, Maurice
    Hurkmans, Coen
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 40 : 88 - 94
  • [22] Intrafractional fiducial marker position variations in stereotactic liver radiotherapy during voluntary deep inspiration breath-hold
    Stick, Line Bjerregaard
    Vogelius, Ivan Richter
    Risum, Signe
    Josipovic, Mirjana
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1116)
  • [23] Selection of patients with left breast cancer for IMRT with deep inspiration breath-hold technique
    Chang, Chih-shen
    Chen, Chia-hsin
    Liu, Kuo-chi
    Ho, Chia-sheng
    Chen, Miao-fen
    JOURNAL OF RADIATION RESEARCH, 2020, 61 (03) : 431 - 439
  • [24] Geometrical uncertainty of heart position in deep-inspiration breath-hold radiotherapy of left-sided breast cancer patients
    Koivumaki, Tuomas
    Tujunen, Juuso
    Viren, Tuomas
    Heikkila, Janne
    Seppala, Jan
    ACTA ONCOLOGICA, 2017, 56 (06) : 879 - 883
  • [25] Dosimetric effect due to the motion during deep inspiration breath hold for left-sided breast cancer radiotherapy
    Tang, Xiaoli
    Cullip, Tim
    Dooley, John
    Zagar, Timothy
    Jones, Ellen
    Chang, Sha
    Zhu, Xiaofeng
    Lian, Jun
    Marks, Lawrence
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (04): : 91 - 99
  • [26] Prospective phase II trial of image-guided radiotherapy in Hodgkin lymphoma: Benefit of deep inspiration breath-hold
    Petersen, Peter M.
    Aznar, Marianne C.
    Berthelsen, Anne K.
    Loft, Annika
    Schut, Deborah A.
    Maraldo, Maja
    Josipovic, Mirjana
    Klausen, Thomas L.
    Andersen, Flemming L.
    Specht, Lena
    ACTA ONCOLOGICA, 2015, 54 (01) : 60 - 66
  • [27] Prolonging deep inspiration breath-hold time to 3 min during radiotherapy, a simple solution
    Vakaet, Vincent
    Van Hulle, Hans
    Schoepen, Max
    Van Caelenberg, Els
    Van Greveling, Annick
    Holvoet, Jeroen
    Monten, Chris
    De Baerdemaeker, Luc
    De Neve, Wilfried
    Coppens, Marc
    Veldeman, Liv
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2021, 28 : 10 - 16
  • [28] The implementation of RapidPlan in predicting deep inspiration breath-hold candidates with left-sided breast cancer
    Rice, Aubrie
    Zoller, Ian
    Kocos, Kevin
    Weller, Dannyl
    DiCostanzo, Dominic
    Hunzeker, Ashley
    Lenards, Nishele
    MEDICAL DOSIMETRY, 2019, 44 (03) : 210 - 218
  • [29] Dosimetric Analysis of Tangential-Based Volumetric Modulated Arc Therapy Implemented Using Deep Inspiration Breath-Hold Technique in the Left Breast Cancer Patients with Breast-Conserving Surgery
    Aslan, Dicle
    Aksozen, Mustafa Tarkan
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2024, 39 (02): : 212 - 226
  • [30] Gastric side effects and the stomach dosimetric analysis in left-sided breast cancer radiotherapy in free-breathing and deep inspiration breath-hold technique
    Yang, Dong
    Piao, Ying
    Yuan, Fengshun
    Chen, Hongtao
    Zhang, Ding
    Li, Xianming
    RADIATION ONCOLOGY, 2022, 17 (01)