Rhodamine-based Cell Permeable Fluoresecent Turn-on Probes for Cupric Ion

被引:4
作者
Mi Xiaolong [1 ]
Jiao Xiaojie [1 ]
Liu Chang [1 ]
He Song [1 ]
Zeng Xianshun [1 ]
机构
[1] Tianjin Univ Technol, Sch Mat Sci & Engn, Key Lab Display Mat & Photoelect Devices, Minist Educ, Tianjin 300384, Peoples R China
来源
CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE | 2016年 / 37卷 / 10期
基金
中国国家自然科学基金;
关键词
Rhodamine; Hydrazide; Cupric ion; Fluorescence probe; Fluorescence imaging; LIVING CELLS; FLUORESCENT CHEMOSENSOR; COPPER IONS; CU2+; CHEMODOSIMETER; EXPOSURE; WATER; DISEASE; SENSOR; ZINC;
D O I
10.7503/cjcu20160402
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Two rhodamine. based fluorescent turn. on probes L1 and L2 were designed and synthesized for the detection of Cu2+ ion. L1 and L2 exhibit high selectivity toward Cu2+ ion over a wide range of metal ions in MeCN/H2O(volume ratio 1:5). The detection limits of the probes are down to 10(-8) mol/L range. Moreover, L1 and L2 can function as excellent fluorescence probes for imaging of cellular Cu2+ by means of fluorescence microscopy.
引用
收藏
页码:1784 / 1791
页数:8
相关论文
共 35 条
[1]   Molecule-based photonically switched half-adder [J].
Andréasson, J ;
Kodis, G ;
Terazono, Y ;
Liddell, PA ;
Bandyopadhyay, S ;
Mitchell, RH ;
Moore, TA ;
Moore, AL ;
Gust, D .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (49) :15926-15927
[2]   Neurodegenerative diseases and oxidative stress [J].
Barnham, KJ ;
Masters, CL ;
Bush, AI .
NATURE REVIEWS DRUG DISCOVERY, 2004, 3 (03) :205-214
[3]   THE KINETICS AND OXYGEN EXCHANGE OF THE CUPRIC ION-CATALYZED HYDROLYSIS OF ALPHA-AMINO ESTERS [J].
BENDER, ML ;
TURNQUEST, BW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1957, 79 (08) :1889-1883
[4]   Coumarin Modified Rhodamine Derivative: Fluorescent Chemosensor Selectively Recognizing Al3+ and Ca2+ [J].
Cao Li ;
Jia Chunman ;
Zhang Qi ;
Chen Da ;
Zhang Chunyan ;
Qian Yaao .
CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2014, 30 (03) :362-367
[5]  
Cowan J.A., 1997, INORGANIC BIOCH INTR, P133
[6]   Signaling recognition events with fluorescent sensors and switches [J].
de Silva, AP ;
Gunaratne, HQN ;
Gunnlaugsson, T ;
Huxley, AJM ;
McCoy, CP ;
Rademacher, JT ;
Rice, TE .
CHEMICAL REVIEWS, 1997, 97 (05) :1515-1566
[7]   A Highly Selective Turn-On Colorimetric, Red Fluorescent Sensor for Detecting Mobile Zinc in Living Cells [J].
Du, Pingwu ;
Lippard, Stephen J. .
INORGANIC CHEMISTRY, 2010, 49 (23) :10753-10755
[8]   A long-wavelength fluorescent chemodosimeter selective for Cu(II) ion in water [J].
Dujols, V ;
Ford, F ;
Czarnik, AW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (31) :7386-7387
[9]   A Fluorescent Ratiometric Chemodosimeter for Cu2+ Based on TBET and Its Application in Living Cells [J].
Fan, Jiangli ;
Zhan, Peng ;
Hu, Mingming ;
Sun, Wen ;
Tang, Jizhou ;
Wang, Jingyun ;
Sun, Shiguo ;
Song, Fengling ;
Peng, Xiaojun .
ORGANIC LETTERS, 2013, 15 (03) :492-495
[10]   Environmental copper: Its dynamics and human exposure issues [J].
Georgopoulos, PG ;
Roy, A ;
Yonone-Lioy, MJ ;
Opiekun, RE ;
Lioy, PJ .
JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART B-CRITICAL REVIEWS, 2001, 4 (04) :341-394