A comparison of classical histology to anatomy revealed by hard X-rays

被引:1
|
作者
Richter, Claus-Peter [1 ,2 ,3 ]
Tan, Xiaodong [1 ]
Young, Hunter [1 ]
Stock, Stuart
Robinson, Alan [1 ]
Byskosh, Orest [1 ]
Zheng, Jing [1 ,3 ]
Soriano, Carmen [4 ]
Xiao, Xianghui [4 ]
Whitlon, Donna [1 ,3 ,5 ]
机构
[1] Northwestern Univ Feinberg, Sch Med, Dept Otolaryngol Head & Neck Surg, 303 E Chicago Ave, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, 2145 Sheridan Rd Evanston, Evanston, IL 60208 USA
[3] Northwestern Univ, Hugh Knowles Ctr Clin & Basic Sci Hearing & Its D, Dept Commun Sci & Disorders, 2240 Campus Dr, Evanston, IL 60208 USA
[4] Argonne Natl Lab, Adv Photon Source, 9700 S Cass Ave B109, Lemont, IL 60439 USA
[5] Interdept Neurosci Program, 320 E Super St,5-474, Chicago, IL 60611 USA
来源
DEVELOPMENTS IN X-RAY TOMOGRAPHY X | 2016年 / 9967卷
关键词
X-rays; phase contrast; histology; kidney; cochlea; hyaline cartilage; PHASE-CONTRAST; SYNCHROTRON-RADIATION; COMPUTED-TOMOGRAPHY; HIGH-RESOLUTION; INNER-EAR; MICROTOMOGRAPHY; TISSUES; MICRO;
D O I
10.1117/12.2239146
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Many diseases trigger morphological changes in affected tissue. Today, classical histology is still the "gold standard" used to study and describe those changes. Classical histology, however, is time consuming and requires chemical tissue manipulations that can result in significant tissue distortions. It is sometimes difficult to separate tissue-processing artifacts from changes caused by the disease process. We show that synchrotron X-ray phase-contrast micro-computed tomography (micro-CT) can be used to examine non-embedded, hydrated tissue at a resolution comparable to that obtained with classical histology. The data analysis from stacks of reconstructed micro-CT images is more flexible and faster than when using the classical, physically embedded sections that are by necessity fixed in a particular orientation. We show that in a three-dimensional (3D) structure with meticulous structural details such as the cochlea and the kidney, micro-CT is more flexible, faster and more convenient for morphological studies and disease diagnoses.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Emerging developments in tomographic imaging with hard X-rays
    Mueller, Bert
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XIII, 2021, 11840
  • [2] Restablished Accretion in Post-outburst Classical Novae Revealed by X-rays
    Hernanz, Margarita
    Ferri, Carlo
    Sala, Gloria
    SIMBOL-X: FOCUSING ON THE HARD X-RAY UNIVERSE, 2009, 1126 : 197 - +
  • [3] Texture and microstructure analysis by diffraction of hard X-rays
    Bunge, HJ
    PHYSICS OF METALS AND METALLOGRAPHY, 2003, 96 : S91 - S103
  • [4] Photoelectron spectroscopy with hard X-rays
    Drube, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 547 (01) : 87 - 97
  • [5] HARD X-RAYS FROM BINARIES
    HAMEURY, JM
    ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES, 1993, 97 (01): : 235 - 239
  • [6] Imaging cochlear soft tissue displacement with coherent x-rays
    Rau, Christoph
    Richter, Claus-Peter
    PHYSICA SCRIPTA, 2015, 90 (10)
  • [7] Spectral variations of flare hard X-rays
    Hudson, HS
    Fárník, F
    SOLAR VARIABILITY: FROM CORE TO OUTER FRONTIERS, VOLS 1 & 2, 2002, 506 : 261 - 264
  • [8] A cryogenically stabilized meV-monochromator for hard X-rays
    Toellner, TS
    Alatas, A
    Said, A
    Shu, D
    Sturhahn, W
    Zhao, J
    JOURNAL OF SYNCHROTRON RADIATION, 2006, 13 : 211 - 215
  • [9] Generalised Cornu spirals: an experimental study using hard x-rays
    Werdiger, Freda
    Kitchen, Marcus J.
    Paganin, David M.
    OPTICS EXPRESS, 2016, 24 (10): : 10620 - 10634
  • [10] Visualizing soft tissue in the mammalian cochlea with coherent hard X-rays
    Rau, C.
    Robinson, I. K.
    Richter, C. -P.
    MICROSCOPY RESEARCH AND TECHNIQUE, 2006, 69 (08) : 660 - 665