Digital microscopic evaluation of vertical marginal discrepancies of CAD/CAM fabricated zirconia cores

被引:5
|
作者
Habib, Syed Rashid [1 ]
机构
[1] King Saud Univ, Coll Dent, Dept Prosthet Dent Sci, POB 60169,King Abdullah Rd, Riyadh 11545, Saudi Arabia
来源
BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK | 2019年 / 64卷 / 02期
关键词
digital microscope; marginal discrepancy; marginal fit; zirconia; zirconia cores; zirconia crowns; CERAMIC MATERIALS; FIT; ADAPTATION; PRECISION; ACCURACY;
D O I
10.1515/bmt-2017-0234
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The aim of this in vitro research study was to evaluate the vertical marginal discrepancies of zirconia (Zr) cores fabricated by five different computer-aided design and manufacturing (CAD/CAM) systems using a digital microscope. Materials and methods: A total of 60 specimens were prepared and randomly divided into five groups (n = 12 each) using the following systems: Ceramill Motion 2 (CM, Amanngirrbach, Germany); Weiland (WI, Ivoclar Vivadent, USA); Cerec (CS, Sirona Dental, USA); Zirkonzahn (ZZ, Gmbh Bruneck, Italy) and Cad4dent (CD, Canada). The specimens were numbered and the vertical marginal discrepancies were evaluated with a digital microscope at 50x magnification. Results: A one-way analysis of variance showed a statistically significant difference (p = 0.002) between the groups. The CM group exhibited the lowest values for the marginal gaps (31.30 +/- 15.12 mu m), while the ZZ group exhibited the highest values for the marginal gaps (44.83 +/- 28.76 mu m) compared to other groups. A post hoc Tukey's test for - multiple comparisons between the experimental groups showed a statistically significant difference (p < 0.05) between the group CM and group CD with group ZZ. The rest of the groups showed no significant differences between them. Variations in the values were observed for the four sites measured with the highest and the least mean marginal gap value of 43.19 +/- 23.84 mu m and 32.49 +/- 12.21 mu m for buccal and lingual sites, respectively. Conclusion: Variations existed in the marginal discrepancy values for the CAD/CAM systems investigated in the study. Vertical marginal discrepancy values observed for various systems investigated in the study were well within the clinically acceptable range.
引用
收藏
页码:207 / 214
页数:8
相关论文
共 50 条
  • [41] Customized Post and Cores Fabricated with CAD/CAM Technology: A Literature Review
    al-Qarni, Faisal
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2022, 15 : 4771 - 4779
  • [42] Marginal and Internal Fit of CAD/CAM Crowns Fabricated Over Reverse Tapered Preparations
    Mejia, Jeison B. Carbajal
    Yatani, Hirofumi
    Wakabayashi, Kazumichi
    Nakamura, Takashi
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E477 - E484
  • [43] Effect of preparation angles on the precision of zirconia crown copings fabricated by CAD/CAM system
    Beuer, Florian
    Edelhoff, Daniel
    Gernet, Wolfgang
    Naumann, Michael
    DENTAL MATERIALS JOURNAL, 2008, 27 (06) : 814 - 820
  • [44] Marginal fit of 3-unit CAD–CAM zirconia frameworks fabricated using cone beam computed tomography scans: an experimental study
    Hüseyin Berkay Belgin
    Ediz Kale
    Tuncer Burak Özçelik
    Burak Yilmaz
    Odontology, 2022, 110 : 339 - 348
  • [45] Three-Dimensional Digital Evaluation of the Fit of Endocrowns Fabricated from Different CAD/CAM Materials
    Zimmermann, Moritz
    Valcanaia, Andre
    Neiva, Gisele
    Mehl, Albert
    Fasbinder, Dennis
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E504 - E509
  • [46] Marginal Design Evaluation for CAM Obtained Zirconia Based Crown Frameworks
    Sandu Liliana
    Topala Florin
    Porojan Sorin
    ADVANCED MATERIALS RESEARCH, 2011, 213 : 349 - 353
  • [47] Evaluation of Marginal Fit of CAD/CAM Ceramic Crowns and Scanning Time Using Different Intraoral Scanning Systems
    Pereira, Leandro Maruki
    de Melo, Barbara Inacio
    Oliveira, Alex Antonio Maciel
    Mendonca, Gustavo
    Raposo, Luis Henrique Araujo
    Prudente, Marcel Santana
    das Neves, Flavio Domingues
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2024, 15 (12)
  • [48] Influence of CAM vs. CAD/CAM scanning methods and finish line of tooth preparation in the vertical misfit of zirconia bridge structures
    Castillo de Oyaguee, Raquel
    Isabel Sanchez-Jorge, Maria
    Sanchez Turrion, Andres
    Monticelli, Francesca
    Toledano, Manuel
    Osorio, Raquel
    AMERICAN JOURNAL OF DENTISTRY, 2009, 22 (02) : 79 - 83
  • [49] Distortion of CAD-CAM-fabricated implant-fixed titanium and zirconia complete dental prosthesis frameworks
    AL-Meraikhi, Hadi
    Yilmaz, Burak
    McGlumphy, Edwin
    Brantley, William A.
    Johnston, William M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (01) : 116 - 123
  • [50] Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems
    Song, Tae-Jin
    Kwon, Taek-Ka
    Yang, Jae-Ho
    Han, Jung-Suk
    Lee, Jai-Bong
    Kim, Sung-Hun
    Yeo, In-Sung
    JOURNAL OF ADVANCED PROSTHODONTICS, 2013, 5 (03) : 219 - 225