Objective: The aim of this in vitro research study was to evaluate the vertical marginal discrepancies of zirconia (Zr) cores fabricated by five different computer-aided design and manufacturing (CAD/CAM) systems using a digital microscope. Materials and methods: A total of 60 specimens were prepared and randomly divided into five groups (n = 12 each) using the following systems: Ceramill Motion 2 (CM, Amanngirrbach, Germany); Weiland (WI, Ivoclar Vivadent, USA); Cerec (CS, Sirona Dental, USA); Zirkonzahn (ZZ, Gmbh Bruneck, Italy) and Cad4dent (CD, Canada). The specimens were numbered and the vertical marginal discrepancies were evaluated with a digital microscope at 50x magnification. Results: A one-way analysis of variance showed a statistically significant difference (p = 0.002) between the groups. The CM group exhibited the lowest values for the marginal gaps (31.30 +/- 15.12 mu m), while the ZZ group exhibited the highest values for the marginal gaps (44.83 +/- 28.76 mu m) compared to other groups. A post hoc Tukey's test for - multiple comparisons between the experimental groups showed a statistically significant difference (p < 0.05) between the group CM and group CD with group ZZ. The rest of the groups showed no significant differences between them. Variations in the values were observed for the four sites measured with the highest and the least mean marginal gap value of 43.19 +/- 23.84 mu m and 32.49 +/- 12.21 mu m for buccal and lingual sites, respectively. Conclusion: Variations existed in the marginal discrepancy values for the CAD/CAM systems investigated in the study. Vertical marginal discrepancy values observed for various systems investigated in the study were well within the clinically acceptable range.
引用
收藏
页码:207 / 214
页数:8
相关论文
共 50 条
  • [1] Evaluation of thickness of CAD/CAM fabricated zirconia cores by digital microscope
    Habib, Syed Rashid
    Al Otaibi, Asim Khaled
    Al Anazi, Talal Ali
    Al Anazi, Samer Mosleh
    TECHNOLOGY AND HEALTH CARE, 2018, 26 (01) : 181 - 185
  • [2] Marginal and Internal Discrepancies Related to Margin Design of Ceramic Crowns Fabricated by a CAD/CAM System
    Assuncao Souza, Rodrigo Othavio
    Ozcan, Mutlu
    Pavanelli, Carlos Augusto
    Buso, Leonardo
    Leao Lombardo, Geraldo Henrique
    Araujo Michida, Silvia Masae
    Melo Mesquita, Alfredo Mikail
    Bottino, Marco Antonio
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (02): : 94 - 100
  • [3] In vitro evaluation of the internal and marginal misfit of CAD/CAM zirconia copings
    Lins, Leonardo
    Bemfica, Vinicius
    Queiroz, Celso
    Canabarro, Antonio
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (03) : 205 - 211
  • [4] In vitro evaluation of marginal discrepancy of monolithic zirconia restorations fabricated with different CAD-CAM systems
    Hamza, Tamer A.
    Sherif, Rana M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (06) : 762 - 766
  • [5] Evaluation of Marginal and Internal Adaptation of Crowns Fabricated with Three Different Zirconia CAD/CAM Materials
    Temizkan Nizaroglu, R.
    Kucuk, C.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2024, 27 (01) : 54 - 61
  • [6] An in vitro evaluation of marginal fit zirconia crowns fabricated by a CAD-CAM dental laboratory and a milling center
    Meirowitz, Avi
    Bitterman, Yoli
    Levy, Sharon
    Mijiritsky, Eitan
    Dolev, Eran
    BMC ORAL HEALTH, 2019, 19 (1)
  • [7] An in vitro evaluation of marginal fit zirconia crowns fabricated by a CAD-CAM dental laboratory and a milling center
    Avi Meirowitz
    Yoli Bitterman
    Sharon Levy
    Eitan Mijiritsky
    Eran Dolev
    BMC Oral Health, 19
  • [8] Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings
    Beuer, Florian
    Aggstaller, Hans
    Richter, Juliane
    Edelhoff, Daniel
    Gernet, Wolfgang
    QUINTESSENCE INTERNATIONAL, 2009, 40 (03): : 243 - 250
  • [9] Marginal and Internal Fit of Monolithic Zirconia Crowns Fabricated by Using Two Different CAD-CAM Workflows: An In Vitro Study
    Cin, Vahap
    Izgi, Ayca Deniz
    Kale, Ediz
    Yilmaz, Burak
    PROSTHESIS, 2023, 5 (01): : 35 - 47
  • [10] Marginal and Internal Discrepancies of Posterior Zirconia-Based Crowns Fabricated with Three Different CAD/CAM Systems Versus Metal-Ceramic
    Ortega, Rocio
    Gonzalo, Esther
    Gomez-Polo, Miguel
    Suarez, Maria J.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (05) : 509 - 511