Emergency endovascular stent graft repair for acute blunt thoracic aortic injury: a retrospective case control study

被引:33
|
作者
Broux, C [1 ]
Thony, F
Chavanon, O
Bach, V
Hacini, R
Sengel, C
Blin, D
Lavagne, P
Girardet, P
Jacquot, C
机构
[1] Grenoble Univ Hosp, Surg Intens Care Unit, F-38043 Grenoble, France
[2] Grenoble Univ Hosp, Dept Radiol, F-38043 Grenoble, France
[3] Grenoble Univ Hosp, Dept Cardiac Surg, F-38043 Grenoble, France
[4] Grenoble Univ Hosp, Cardiovasc & Thorac Intens Care Unit, F-38043 Grenoble, France
关键词
blunt thoracic aortic injury; endovascular repair; stent graft; surgical treatment; multiple trauma introduction;
D O I
10.1007/s00134-006-0115-8
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To compare surgical and endovascular stent graft (ESG) treatment of blunt thoracic aortic injury (BAI) in the emergency setting. Design and setting: Retrospective case control study in two surgical intensive care units of a university hospital. Patients: 30 patients who presented with BAI between 1995 and 2005: 17 treated surgically and 13 by ESG. The two groups were comparable for the severity of trauma and mean delay before treatment; the mean age was higher in the ESG group (46 +/- 18 vs. 35 +/- 15 years). Results: In the surgical group time spent in the operating theater was longer (310 +/- 130 vs. 140 +/- 48 min) and blood losses higher (2000 +/- 1300 vs. no significant bleeding); aortic clamping time was 48 +/- 20 min. The mortality rate was 15% with ESG (n = 2) and 23% with surgery (n = 4). Complications of the procedure were more frequent in the surgical group (1 vs. 7). In the ESG group there was one pulmonary embolism. In the surgical group there were three neurological complications, one acute aortic dissection, one perioperative rupture, one periprosthetic leak, and one septic shock. Two complications (postoperative aortic dissection and paraplegia) appeared in the same patient in the surgical group. Intensive care unit length of stay, duration of mechanical ventilation, and catecholamine support were similar in the two groups. Conclusions: Stent graft for emergency treatment of BAI is efficient and is associated with fewer complications than surgical treatment.
引用
收藏
页码:770 / 774
页数:5
相关论文
共 50 条
  • [31] Iliac Leg and Abdominal Aortic Cuff Stent-Graft for Blunt Thoracic Aortic Injury in Young Patient
    Muradi, Akhmadu
    Yamaguchi, Masato
    Idoguchi, Koji
    Nomura, Yoshikatsu
    Okada, Takuya
    Okita, Yutaka
    Sugimoto, Koji
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 20 : 825 - 828
  • [32] Males and females have similar mortality after thoracic endovascular aortic repair for blunt thoracic aortic injury
    Rastogi, Vinamr
    Romijn, Anne-Sophie C.
    Yadavalli, Sai Divya
    Marcaccio, Christina L.
    Jongkind, Vincent
    Zettervall, Sara L.
    Quiroga, Elina
    Saillant, Noelle N.
    Verhagen, Hence J. M.
    Schermerhorn, Marc L.
    JOURNAL OF VASCULAR SURGERY, 2023, 77 (04) : 997 - 1005
  • [33] Results of a multicenter, prospective trial of thoracic endovascular aortic repair for blunt thoracic aortic injury (RESCUE trial)
    Khoynezhad, Ali
    Azizzadeh, Ali
    Donayre, Carlos E.
    Matsumoto, Alan
    Velazquez, Omaida
    White, Rodney
    JOURNAL OF VASCULAR SURGERY, 2013, 57 (04) : 899 - +
  • [34] One-year results of thoracic endovascular aortic repair for blunt thoracic aortic injury (RESCUE trial)
    Khoynezhad, Ali
    Donayre, Carlos E.
    Azizzadeh, Ali
    White, Rodney
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 149 (01) : 155 - U282
  • [35] Percutaneous endovascular repair of blunt thoracic aortic transection
    Peterson, BG
    Matsumura, JS
    Morasch, MD
    West, MA
    Eskandari, MK
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (05): : 1062 - 1065
  • [36] Endovascular Repair of Blunt Traumatic Thoracic Aortic Injuries
    Vahedian, Mehrdad
    Rastinnia, Somayeh
    Taghizadeh, Masumeh
    TRAUMA MONTHLY, 2015, 20 (04)
  • [37] Endovascular Repair of a Blunt Abdominal Aortic Injury
    Tobler, William D.
    Tan, Tze-Woei
    Farber, Alik
    INTERNATIONAL JOURNAL OF ANGIOLOGY, 2012, 21 (02) : 117 - 120
  • [38] Clinical results of endovascular stent graft repair for fifty cases of thoracic aortic aneurysms
    Kawaguchi S.
    Ishimaru S.
    Shimazaki T.
    Yokoi Y.
    Koizumi N.
    Obitsu Y.
    Ishikawa M.
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 1998, 46 (10): : 971 - 975
  • [39] Induction of ventricular fibrillation to facilitate endovascular stent graft repair of thoracic aortic aneurysms
    Kahn, RA
    Marin, ML
    Hollier, L
    Parsons, R
    Griepp, R
    ANESTHESIOLOGY, 1998, 88 (02) : 534 - 536
  • [40] Emergent Endovascular Repair of a Ruptured Ascending Aorta Pseudoaneurysm With Thoracic Aortic Stent Graft
    Hanna Quesada, Franklin
    Hanna Rodriguez, Franklin
    Moroni, Francesco
    Marin, Andres
    Nieto, James
    Mejia, Diego
    Castrillon, Jhon
    Harada Ribeiro, Marcelo
    Palma Dallan, Luis Augusto
    Campos, Carlos Augusto H. M.
    Salazar, Santiago
    Azzalini, Lorenzo
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 40 : S167 - S169