Energy performance analysis of a solar-cooled building in Tunisia: Passive strategies impact and improvement techniques

被引:42
作者
Soussi, Meriem [2 ]
Balghouthi, Moncef [1 ]
Guizani, Amenallah [1 ]
机构
[1] Res & Technol Ctr Energy CRTEn, Hammam Lif 2050, Tunisia
[2] Natl Engn Sch Tunis ENIT, Tunis 1002, Tunisia
关键词
Passive techniques; Storage wall; Glazing; Cool roof; TRNSYS; Building; Energy performance; Solar cooling; WALLS; SIMULATION;
D O I
10.1016/j.enbuild.2013.08.033
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The energy performance of a solar cooled office building located in Tunisia is studied using the TRNSYS software. The simulations assessed the real case study and analysed the impact of its architectural characteristics and passive techniques on its energy requirements. The impact of solar passive heating techniques already implemented in the envelope is studied in order to take advantage of them in winter and prevent their overheating effect in summer. Besides, additional passive cooling solutions are proposed and studied aiming to decrease the cooling requirements. The results showed that the insulation of the walls and the cool roof guarantee important savings of 46% in winter and 80% in summer compared to an ordinary building. The study was also focused on the impact of the trombe walls and showed that the heating requirements are raised by 20.7% if the storage walls are omitted from the construction. The integration of internal curtains in the windows and movable solar overhangs shading the storage walls and the low-emissive Argon coatings allowed a relevant reduction in total energy demands: 60.3% for heating demands and 47.7% for cooling demands. The peak cooling load has decreased from an initial value of 14.09-8.68 kW. Thanks to this relevant reduction, a technical improvement solution consisting in a cooling storage was proposed to increase the solar cooling performances. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:374 / 386
页数:13
相关论文
共 23 条
[1]  
American Society of Heating Refrigerating and Air-Conditioning Engineers, 2005, HDB FUND
[2]   Feasibility of solar absorption air conditioning in Tunisia [J].
Balghouthi, M. ;
Chahbani, M. H. ;
Guizani, A. .
BUILDING AND ENVIRONMENT, 2008, 43 (09) :1459-1470
[3]   Investigation of a solar cooling installation in Tunisia [J].
Balghouthi, M. ;
Chahbani, M. H. ;
Guizani, A. .
APPLIED ENERGY, 2012, 98 :138-148
[4]  
Balghouthi M., 2009, THESIS
[5]   Possibilities and limitations of natural ventilation in restored industrial archaeology buildings with a double-skin facade in Mediterranean climates [J].
Ballestini, G ;
De Carli, M ;
Masiero, N ;
Tombola, G .
BUILDING AND ENVIRONMENT, 2005, 40 (07) :983-995
[6]   Analysis of thermal performance of building attached sunspace [J].
Bataineh, Khaled M. ;
Fayez, Nadia .
ENERGY AND BUILDINGS, 2011, 43 (08) :1863-1868
[7]   Influence of glass curtain walls on the building thermal energy consumption under Tunisian climatic conditions: The case of administrative buildings [J].
Bouden, Chiheb .
RENEWABLE ENERGY, 2007, 32 (01) :141-156
[8]   Energy conservation in honey storage building using Trombe wall [J].
Chel, Arvind ;
Nayak, J. K. ;
Kaushik, Geetanjali .
ENERGY AND BUILDINGS, 2008, 40 (09) :1643-1650
[9]   Energy-efficient envelope design for high-rise apartments [J].
Cheung, CK ;
Fuller, RJ ;
Luther, MB .
ENERGY AND BUILDINGS, 2005, 37 (01) :37-48
[10]   Appraisal of thermal performance of a glazed office with a solar control coating: Cases in Mexico and Canada [J].
Gijon-Rivera, M. ;
Alvarez, G. ;
Beausoleil-Morrison, I. ;
Xaman, J. .
BUILDING AND ENVIRONMENT, 2011, 46 (05) :1223-1233