Glucose biosensor based on a flexible Au/ZnO film to enhance the glucose oxidase catalytic response

被引:10
作者
Chavez-Urbiola, I. R. [1 ]
Resendiz-Jaramillo, A. Y. [2 ]
Willars-Rodriguez, F. J. [3 ]
Martinez-Saucedo, G. [1 ]
Arriaga, L. G. [4 ]
Alcantar-Pena, Jesus [1 ]
Escalona-Villalpando, Ricardo A. [2 ]
Ledesma-Garcia, J. [2 ]
机构
[1] Ctr Ingn & Desarrollo Ind, Ave Playa Pie Cuesta 702, Santiago De Queretaro 76125, Queretaro, Mexico
[2] Univ Autonoma Queretaro, Fac Ingn, Div Invest & Posgrad, Santiago De Queretaro 76010, Mexico
[3] CINVESTAV Queretaro, Libramiento Norponiente 2000, Queretaro 76230, Mexico
[4] Ctr Invest & Desarrollo Tecnol Electroquim, Queretaro 76703, Mexico
关键词
ZnO film; Glucose biosensor; Glucose oxidase enzyme; Electron -beam evaporation; Polyamide filter -membrane; NONENZYMATIC DETECTION; OPTICAL-PROPERTIES; ZNO FILMS; NANOPARTICLES; SENSOR; IMMOBILIZATION; NANOCOMPOSITES; GOLD;
D O I
10.1016/j.jelechem.2022.116941
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present work shows the influence of the isoelectric indirect effect of the semiconductor ZnO in the enzymatic immobilization in a glucose biosensor. For this purpose, thin films based on Au and Au/ZnO were synthesized on a microstructured flexible substrate of polyamide filter membrane (P.F) and characterized by FESEM and XRD. Both flexible surfaces were used to immobilize glucose oxidase (GOx) enzyme mixed with ferrocene methanol (Fc) and multiwalled carbon nanotubes (GOx-Fc/MWCNT). Subsequently, these surfaces were used as working electrodes to be evaluated as glucose biosensors. The effect of the ZnO film was compared. The performance of the flexible substrate based on Au/GOx-Fc/MWCNT and Au/ZnO/GOx-Fc/ MWCNT as glucose sensor showed similar linearity between 0 and 12 mM glucose; however a higher sensitivity (30.00 mu A mM-1 cm-2) and lower limit of detection and quantification values were obtained (0.25 mM and 0.83 mM, respectively) when ZnO thin film was used. The results suggest that the ZnO thin film in junction with GOx enzyme enhance the immobilization process of the biocatalyst, resulting in an improvement of the glucose biosensor parameters.
引用
收藏
页数:7
相关论文
共 46 条
  • [31] Nonenzymatic electrochemical detection of glucose using well-distributed nickel nanoparticles on straight multi-walled carbon nanotubes
    Nie, Huagui
    Yao, Zhen
    Zhou, Xuemei
    Yang, Zhi
    Huang, Shaoming
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 30 (01) : 28 - 34
  • [32] Highly Sensitive and Selective Nonenzymatic Detection of Glucose Using Three-Dimensional Porous Nickel Nanostructures
    Niu, Xiangheng
    Lan, Minbo
    Zhao, Hongli
    Chen, Chen
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (07) : 3561 - 3569
  • [33] Glucose oxidase probe as a surface-enhanced Raman scattering sensor for glucose
    Qi, Guohua
    Wang, Yi
    Zhang, Biying
    Sun, Dan
    Fu, Cuicui
    Xu, Weiqing
    Xu, Shuping
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (26) : 7513 - 7520
  • [34] ITO electrode modified with Pt nanodendrites-decorated ZnO nanorods for enzymatic glucose sensor
    Ridhuan, Nur Syafinaz
    Mohamad Nor, Noorhashimah
    Abdul Razak, Khairunisak
    Lockman, Zainovia
    Zakaria, Nor Dyana
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2021, 25 (03) : 1065 - 1072
  • [35] Mn doped and undoped ZnO films: A comparative structural, optical and electrical properties study
    Shinde, VR
    Gujar, TP
    Lokhande, CD
    Mane, RS
    Han, SH
    [J]. MATERIALS CHEMISTRY AND PHYSICS, 2006, 96 (2-3) : 326 - 330
  • [36] New ZnO nanostructures as non-enzymatic glucose biosensors
    Tarlani, Aliakbar
    Fallah, Mahtab
    Lotfi, Behzad
    Khazraei, Avideh
    Golsanamlou, Sommayeh
    Muzart, Jacques
    Mirza-Aghayan, Maryam
    [J]. BIOSENSORS & BIOELECTRONICS, 2015, 67 : 601 - 607
  • [37] Designing of a stable and selective glucose biosensor by glucose oxidase immobilization on glassy carbon electrode sensitive to H2O2 via nanofiber interface
    Temocin, Zulfikar
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2021, 51 (02) : 283 - 293
  • [38] Therese M. J., 2020, International Journal of Recent Technology and Engineering (IJRTE), V9, P304
  • [39] Stainless steel 304 needle electrode for precise glucose biosensor with high signal-to-noise ratio
    Vinh Xuan Le
    Lee, Haeun
    Nguyen Sy Pham
    Bong, Sungyool
    Oh, Hyeri
    Cho, Sang-Hoon
    Shin, Ik-Soo
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2021, 346 (346):
  • [40] Zinc oxide nanocomb biosensor for glucose detection
    Wang, J. X.
    Sun, X. W.
    Wei, A.
    Lei, Y.
    Cai, X. P.
    Li, C. M.
    Dong, Z. L.
    [J]. APPLIED PHYSICS LETTERS, 2006, 88 (23)