Use of line surge arresters for the improvement of the lightning performance of 63 kV and 90 kV shielded and unshielded transmission lines

被引:15
|
作者
Sadovic, S
Joulie, R
Tartier, S
Brocard, E
机构
关键词
lightning performance; line surge arresters; arrester energy duties; overvoltages;
D O I
10.1109/61.636955
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The lightning performance of 63 kV and 90 kV shielded and unshielded lines, protected by line surge arresters are considered. A specialized software package is used for the computation of the line fast front transients. A Monte Carlo statistical method, together with a three-dimensional electrogeometric model is used to determine the lightning stroke locations. Different arrester installation configurations are analyzed and compared. The energy duties of the line surge arresters are computed statistically.
引用
收藏
页码:1232 / 1240
页数:9
相关论文
共 50 条
  • [21] Lightning Protection of 500-kV DC Gas-Insulated Lines (GIL) With Integrated Surge Arresters
    Goll, Felix
    Witzmann, Rolf
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (03) : 1602 - 1610
  • [23] Case Study of the Lightning Performance of a 230 kV Transmission Line
    Humayun, Muhammad
    Schoene, Jens
    Mueller, Dave
    Pallem, Chandra
    2018 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2018,
  • [24] LIGHTNING PERFORMANCE OF TVAS 500-KV AND 161-KV TRANSMISSION-LINES
    WHITEHEAD, JT
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (03): : 752 - 768
  • [25] Lightning Performance of Transmission Lines Partially Protected by Surge Arresters Considering Typical Brazilian Conditions
    Alipio, Rafael
    Duarte, Matheus H. R.
    Dias, Jessica C. A.
    De Miranda, Audine S.
    2017 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XIV SIPDA), 2017, : 365 - 369
  • [26] Studying of Lightning Surge Transient Effect on 500 kV Quadruple Circuit Transmission Line
    Kusuma, Aristo Adi
    Pramana, Putu Agus Aditya
    Munir, Buyung S.
    Ayu, Rica S.
    2016 6TH INTERNATIONAL ANNUAL ENGINEERING SEMINAR (INAES), 2016, : 276 - 279
  • [27] Development and application effect of polymeric surge ZnO arresters for 500kV compact transmission line
    He, JL
    Zeng, R
    Gao, YM
    Wu, WH
    Chen, SM
    Su, Q
    Han, SW
    Cho, HG
    2000 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS I-III, PROCEEDINGS, 2000, : 1449 - 1454
  • [28] Experimental study on lightning surge response of 500-kV transmission tower with overhead lines
    Motoyama, Hideki
    Kinoshita, Yasuhide
    Nonaka, Katsumasa
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 2488 - 2495
  • [29] Lightning performance improvement of the Swaziland electricity board transmission system (66kV & 132kV lines) - Results of the pilot project
    Mswane, L. M.
    Gaunt, C. T.
    IEEE Power Engineering Society Inaugural 2005 Conference and Exposition in Africa, 2005, : 364 - 370
  • [30] 110- to 330-kV substation surge protection against lightning surge coming from transmission lines
    N. A. Mufid-Zade
    H. Houassine
    S. M. Tagi-Zade
    Russian Electrical Engineering, 2012, 83 (8) : 447 - 452