Adhesion between prefabricated fiber-reinforced posts and different composite resin cores: A microtensile bond strength evaluation

被引:0
作者
Salameh, Z
Papacchin, F
Ounsi, HF
Goracci, C
Tashkandi, E
Ferrari, M
机构
[1] Univ Siena, Dept Dent Mat, I-53100 Siena, Italy
[2] St Joseph Univ, Dept Endodont, Beirut, Lebanon
[3] Dent Dev & Res Fdn, Beirut, Lebanon
[4] King Saud Univ, Dept Prosthet Dent Sci, Riyadh, Saudi Arabia
[5] Univ Siena, Dept Dent Mat & Restorat Dent, I-53100 Siena, Italy
关键词
prefabricated FRC post; core material; composite resin; dual-cure composites; bond strength; microtensile testing;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to evaluate the bond strengths between various resin composites used as core materials (Multicore Flow, Ivoclar-Vivadent; Tetric Flow, Ivoclar-Vivadent; Filtek Flow, 3M-ESPE; Tetric Ceram, Ivoclar-Vivadent; Filtek Z250, 3M-ESPE), and an FRC post (FRC Postec Plus, Ivoclar-Vivadent) by means of the microtensile nontrimming technique. Materials and Methods: Five experimental groups were used. For the microtensile nontrimming technique, 45 to 50 beam-shaped specimens per group were obtained from cylinders of core material, which had been built up around the post by progressively adding small increments of composite resin. Each specimen was loaded in tension until failure at either one of the two post/core interfaces present in each stick. The differences in interfacial bond strength among the groups were tested for statistical significance with the one-way ANOVA test, followed by the Dunnett test for post-hoc comparisons. Results: The measured bond strengths in MPa were 17.29 +/- 6.02 for FRC+MultiCore Flow, 16.37 +/- 6.92 for FRC+Tetric Flow, 13.14 +/- 5.35 for FRC + Filtek Flow, 12.38 +/- 4.34 for FRC + Tetric Ceram, and 10.75 +/- 5.43 for FRC + Filtek Z250. The statistical analysis revealed that MultiCore Flow achieved significantly higher bond strengths than Filtek Flow (p = 0.03), Tetric Ceram (p < 0.001), and Filtek Z250 (p < 0.001). The bond strength of Tetric Flow was significantly higher than that of Filtek Z250 (p = 0.003). Conclusion: For core buildup on a fiber post, dual-cure composites appear to be preferable to light-curing composites.
引用
收藏
页码:113 / 117
页数:5
相关论文
共 27 条
[1]  
Ainamo A, 1992, Int Dent J, V42, P311
[2]   Resistance to fracture of endodontically treated teeth restored with different post systems [J].
Akkayan, B ;
Gülmez, T .
JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (04) :431-437
[3]   Stiffness, elastic limit, and strength of newer types of endodontic posts [J].
Asmussen, E ;
Peutzfeldt, A ;
Heitmann, T .
JOURNAL OF DENTISTRY, 1999, 27 (04) :275-278
[4]   Microtensile bond strength between adhesive cements and root canal dentin [J].
Bouillaguet, S ;
Troesch, S ;
Wataha, JC ;
Krejci, I ;
Meyer, JM ;
Pashley, DH .
DENTAL MATERIALS, 2003, 19 (03) :199-205
[5]  
Duret B, 1990, Chir Dent Fr, V60, P131
[6]  
Ferrari M., 2002, FIBER POSTS CHARACTE, V1st ed.
[7]   A retrospective study of 236 patients with teeth restored by carbon fiber reinforced epoxy resin posts [J].
Fredriksson, M ;
Astback, J ;
Pamenius, M ;
Arvidson, K .
JOURNAL OF PROSTHETIC DENTISTRY, 1998, 80 (02) :151-157
[8]  
Freedman G., 2002, DENT TODAY, V21, P118
[9]   Fatigue testing and microscopic evaluation of post and core restorations under artificial crowns [J].
Gateau, P ;
Sabek, M ;
Dailey, B .
JOURNAL OF PROSTHETIC DENTISTRY, 1999, 82 (03) :341-347
[10]   The adhesion between prefabricated FRC posts and composite resin cores: microtensile bond strength with and without post-silanization [J].
Goracci, C ;
Raffaelli, O ;
Monticelli, F ;
Balleri, B ;
Bertilli, E ;
Ferrari, M .
DENTAL MATERIALS, 2005, 21 (05) :437-444