Mixed mode HILIC/anion exchange separations on latex coated silica monoliths

被引:28
|
作者
Ibrahim, Mohammed E. A. [1 ]
Lucy, Charles A. [1 ]
机构
[1] Univ Alberta, Dept Chem, Gunning Lemieux Chem Ctr, Edmonton, AB T6G 2G2, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
HILIC; Monolith; Ion exchange; Latex; Nanoparticles; Silica; HYDROPHILIC-INTERACTION CHROMATOGRAPHY; PERFORMANCE LIQUID-CHROMATOGRAPHY; POLAR STATIONARY PHASES; ION CHROMATOGRAPHY; CAPILLARY ELECTROCHROMATOGRAPHY; INORGANIC ANIONS; REVERSED-PHASE; HPLC COLUMNS; RETENTION; ANALYTES;
D O I
10.1016/j.talanta.2012.07.069
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bare silica monoliths do not possess anion exchange sites hence they show low retention for anions. Moreover, bare silica monoliths show low retention in hydrophilic interaction liquid chromatography (HILIC). Coating the silica surface with cationic nanoparticles e.g. AS9-SC (latex A), AS12A (latex B) and DNApac (latex C) increases the thickness of the water layer on the Onyx silica monolith 8-10 times enabling HILIC retention when a high % acetonitrile (ACN) mobile phase is used. The formed water layer by itself is not sufficient to perform good separation of the studied anions (acetate, formate, nitrate, bromate, thiocyanate and iodide). On the other hand, the latex nanoparticles introduce positively charged sites, making anion exchange chromatography possible, with the anion exchange capacity varying with the latex adsorbed (44.1 +/- 0.2, 4.4 +/- 0.1 and 14.0 +/- 0.7 mu eq/column for latex A, B and C, respectively). Latex A nanoparticles which provided the highest ion exchange capacity separated all tested anions with reasonable resolution. Fast separation (2.5 min) of acetate, formate, nitrate, bromate, thiocyanate and iodide was performed using the latex A coated silica monolith. The obtained efficiencies are 13,000-50,000 plates/m at 3 mL/min with a minimum resolution of 0.85. Retention is mixed mode under HILIC conditions with HILIC dominating for the kosmotropic anions and ion exchange dominating for the chaotropic anions. The two different brands of silica monoliths (Merck Chromolith and Phenomenex Onyx) coated with the same latex A nanoparticles displayed similar water layer volumes, ion exchange capacity and selectivity. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:313 / 319
页数:7
相关论文
共 50 条
  • [31] Silica-Based Phenyl and Octyl Bifunctional Imidazolium as a New Mixed-Mode Stationary Phase for Reversed-Phase and Anion-Exchange Chromatography
    Qiong Jiang
    Wenjie Zhao
    Hongdeng Qiu
    Shusheng Zhang
    Chromatographia, 2016, 79 : 1437 - 1443
  • [32] Performance evaluation of 2-undecylimidazole/propyl methacrylate bifunctional silica gel for mixed-mode reversed-phase/anion-exchange chromatography
    Hu, Zhefei
    Jiang, Yanhao
    Cao, Panpan
    Liu, Yanjuan
    Zhang, Yuefei
    Chen, Wei
    Tang, Sheng
    MICROCHEMICAL JOURNAL, 2023, 191
  • [33] Silica-Based Phenyl and Octyl Bifunctional Imidazolium as a New Mixed-Mode Stationary Phase for Reversed-Phase and Anion-Exchange Chromatography
    Jiang, Qiong
    Zhao, Wenjie
    Qiu, Hongdeng
    Zhang, Shusheng
    CHROMATOGRAPHIA, 2016, 79 (21-22) : 1437 - 1443
  • [34] Comparison of mixed-mode anion-exchange performance of N-vinylimidazole-divinylbenzene sorbent
    Fontanals, Nuria
    Trammell, Brian C.
    Galia, Marina
    Marce, Rosa Maria
    Iraneta, Pamela C.
    Borrull, Francesc
    Neue, Uwe D.
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (11) : 1622 - 1629
  • [35] Fabrication of naphthol-based phenolic polymer coated-silica for mixed-mode chromatography
    Hu, Yongxing
    Ihara, Hirotaka
    Takafuji, Makoto
    JOURNAL OF CHROMATOGRAPHY OPEN, 2022, 2
  • [36] New reversed-phase/anion-exchange/hydrophilic interaction mixed-mode stationary phase based on dendritic polymer-modified porous silica
    Li, Yun
    Yang, Jiajia
    Jin, Jing
    Sun, Xiaoli
    Wang, Longxing
    Chen, Jiping
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1337 : 133 - 139
  • [37] The effect of kosmotropic salts on aggregate removal from monoclonal antibodies in mixed-mode anion exchange chromatography
    Konrad, Susanne
    Graf, Tobias
    Falkenstein, Roberto
    CURRENT RESEARCH IN BIOTECHNOLOGY, 2023, 6
  • [38] A weak anion-exchange/reversed-phase mixed-mode HPLC column and its applications
    Liu, Xiaodong
    Pohl, Christopher
    AMERICAN LABORATORY, 2007, 39 (18) : 22 - +
  • [39] Silica-based monolithic columns with mixed-mode reversed-phase/weak anion-exchange selectivity principle for high-performance liquid chromatography
    Nogueira, Raquel
    Lubda, Dieter
    Leitner, Alexander
    Bicker, Wolfgang
    Maier, Norbert M.
    Laemmerhofer, Michael
    Lindner, Wolfgang
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (07) : 966 - 978
  • [40] Dendrimer-functionalized mesoporous silica as a reversed-phase/anion-exchange mixed-mode sorbent for solid phase extraction of acid drugs in human urine
    Li, Yun
    Yang, Jiajia
    Huang, Chaonan
    Wang, Longxing
    Wang, Jincheng
    Chen, Jiping
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1392 : 28 - 36