Comparison of Different Pacing Strategies to Minimize Phrenic Nerve Stimulation in Cardiac Resynchronization Therapy

被引:10
作者
Huizar, Jose F. [1 ,2 ]
Kaszala, Karoly [1 ,2 ]
Koneru, Jayanthi N. [1 ,2 ]
Thacker, Leroy R. [2 ]
Ellenbogen, Kenneth A. [2 ]
机构
[1] McGuire VA Med Ctr, Richmond, VA 23249 USA
[2] Virginia Commonwealth Univ, Pauley Heart Ctr, Richmond, VA USA
关键词
biventricular pacing; cardiac resynchronization therapy; heart failure; implantable cardioverter defibrillator; pacing thresholds; phrenic nerve stimulation; VENTRICULAR LEAD IMPLANTATION; CONFIGURATIONS; THRESHOLDS; MANAGEMENT;
D O I
10.1111/jce.12159
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pacing Strategies to Minimize PN Stimulation. Introduction: Phrenic nerve (PN) stimulation (PNS) frequently limits cardiac resynchronization therapy (CRT). Yet, pacing strategies to minimize PNS have not been systematically compared. We propose to: (1) compare different pacing strategies to minimize PNS in CRT and (2) evaluate differences between PN and left ventricular (LV) capture thresholds among LV pacing configurations. Methods and Results: PN and LV thresholds were obtained using 6 LV configurations in 28 patients with any PNS during CRT implantation or replacement. Incidence of PNS was compared in all LV configurations by programming pacing output to (1) One Volt (V) above LV threshold, (2) triple pulse width (PW) at LV threshold, and (3) 1.5 times LV threshold for each patient. PN thresholds and PN strength-duration curves were statistically different between configurations (P < 0.05). Ring -> RVcoil and Ring -> Can had the largest difference between PN and LV thresholds. Pacing output programmed to 1.5 times LV threshold, 1 V above LV threshold, and triple PW at LV threshold had similar probability of PNS between LV configurations. However, 1 V above LV threshold and triple PW at LV threshold frequently resulted in poor (<30%) LV capture safety margin (14-43% and 53-68%, respectively). Freedom from PNS (programmed output at twice LV threshold) was found in 88%, 84%, and 52% with 6, 3, or 2 available LV configurations, respectively. Conclusion: Multiple LV pacing configurations marginally increase the probability of avoiding PNS by electronic reprogramming. Pacing output programmed to 1.5 times LV threshold is an additional alternative to minimize PNS when electronic reprogramming options are limited.
引用
收藏
页码:1008 / 1014
页数:7
相关论文
共 13 条
[1]   Six year experience of transvenous left ventricular lead implantation for permanent biventricular pacing in patients with advanced heart failure: technical aspects [J].
Alonso, C ;
Leclercq, C ;
d'Allonnes, FR ;
Pavin, D ;
Victor, F ;
Mabo, P ;
Daubert, JC .
HEART, 2001, 86 (04) :405-410
[2]   Management of Phrenic Stimulation in CRT Patients over the Long Term: Still an Unmet Need ? [J].
Biffi, Mauro ;
Bertini, Matteo ;
Ziacchi, Matteo ;
Gardini, Beatrice ;
Mazzotti, Andrea ;
Massaro, Giulia ;
Diemberger, Igor ;
Martignani, Cristian ;
Valzania, Cinzia ;
Boriani, Giuseppe .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (10) :1201-1208
[3]   Phrenic Stimulation A Challenge for Cardiac Resynchronization Therapy [J].
Biffi, Mauro ;
Moschini, Carlotta ;
Bertini, Matteo ;
Saporito, Davide ;
Ziacchi, Matteo ;
Diemberger, Igor ;
Valzania, Cinzia ;
Domenichini, Giulia ;
Cervi, Elena ;
Martignani, Cristian ;
Sangiorgi, Diego ;
Branzi, Angelo ;
Boriani, Giuseppe .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (04) :402-410
[4]   The effect of electronic repositioning on left ventricular pacing and phrenic nerve stimulation [J].
Champagne, Jean ;
Healey, Jeffrey S. ;
Krahn, Andrew D. ;
Philippon, Francois ;
Gurevitz, Osnat ;
Swearingen, Anne ;
Glikson, Michael .
EUROPACE, 2011, 13 (03) :409-415
[5]  
Ellenbogen K., 2011, Clinical Cardiac Pacing, Defibrillation, and Resynchronization Therapy
[6]   Programmable multiple pacing configurations help to overcome high left ventricular pacing thresholds and avoid phrenic nerve stimulation [J].
Gurevitz, O ;
Nof, E ;
Carasso, S ;
Luria, D ;
Bar-Lev, D ;
Tanami, N ;
Eldar, M ;
Glikson, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (12) :1255-1259
[7]   Disparity in Left Ventricular Stimulation Among Different Pacing Configurations in Cardiac Resynchronization Therapy [J].
Huizar, Jose F. ;
Kaszala, Karoly ;
Koneru, Jayanthi ;
Kowalski, Marcin ;
Thacker, Leroy R., II ;
Wood, Mark A. ;
Ellenbogen, Kenneth A. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (01) :140-146
[8]   Left ventricular lead implantation at a phrenic stimulation site is safe and effective [J].
Jastrzebski, Marek ;
Bacior, Bogumila ;
Wojciechowska, Wiktoria ;
Czarnecka, Danuta .
EUROPACE, 2011, 13 (04) :520-525
[9]   Clinical efficacy of left ventricular pacing vector programmability in cardiac resynchronization therapy defibrillator patients for management of phrenic nerve stimulation and/or elevated left ventricular pacing thresholds: insights from the Efface Phrenic Stim study [J].
Klein, Norbert ;
Klein, Maika ;
Weglage, Heinrich ;
Przibille, Oliver ;
Fischer, Sven ;
Trappe, Hans-Joachim ;
Birkenhauer, Frank ;
Pfeiffer, Dietrich .
EUROPACE, 2012, 14 (06) :826-832
[10]   Long-term retention of cardiac resynchronization therapy [J].
Knight, BP ;
Desai, A ;
Coman, J ;
Faddis, M ;
Yong, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (01) :72-77