A Stationary-Sources and Rotating-Detectors Computed Tomography Architecture for Higher Temporal Resolution and Lower Radiation Dose

被引:18
作者
Cao, Guohua [1 ]
Liu, Baodong [2 ,3 ,4 ]
Gong, Hao [1 ]
Yu, Hengyong [2 ]
Wang, Ge [5 ]
机构
[1] Virginia Polytech Inst & State Univ, Wake Forest Univ, Virginia Tech, Sch Biomed Engn & Sci, Blacksburg, VA 24061 USA
[2] Wake Forest Univ Hlth Sci, Wake Forest Univ, Virginia Tech, Sch Biomed Engn & Sci, Winston Salem, NC 27157 USA
[3] Chinese Acad Sci, Inst High Energy Phys, Key Lab Nucl Anal Tech, Beijing 100049, Peoples R China
[4] Beijing Engn Res Ctr Radiog Tech & Equipment, Beijing 100049, Peoples R China
[5] Rensselaer Polytech Inst, Dept Biomed Engn, Troy, NY 12180 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Computed tomography; temporal resolution; radiation dose; multisource; interior tomography;
D O I
10.1109/ACCESS.2014.2363367
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In current computed tomography (CT) architecture, both X-ray tubes and X-ray detectors are rotated mechanically around an object to collect a sufficient number of projections. This architecture has been shown to not be fast enough for patients with high or irregular heart rates. Furthermore, both X-ray beams and detectors of the current architecture are made wide enough, so that the entire object is covered in the lateral direction without data truncation. Although novel acquisition protocols have recently been developed to reduce a radiation exposure, the high radiation dose from CT imaging remains a heightened public concern (especially for cardiac CT). The current CT architecture is a major bottleneck to further increase the temporal resolution and reduce the radiation dose. To overcome these problems, we present an innovative stationary-sources rotating-detectors CT (SSRD-CT) architecture based on the three stationary distributed X-ray sources and three smaller rotating X-ray detectors. Each distributed X-ray source has similar to 100 distinctive X-ray focal spots, and each detector has a narrower width compared with the conventional CT detectors. The SSRD-CT will have a field-of-view of 200 mm in diameter at isocenter, which is large enough to image many internal organs, including hearts. X-rays from the distributed sources are activated electronically to simulate the mechanical spinning of conventional single-beam X-ray sources with a high speed. The activation of individual X-ray beam will be synchronized to the corresponding rotating detector at the opposite end. Three source-detector chains can work in parallel to acquire three projections simultaneously and improve temporal resolution. Lower full-body radiation dose is expected for the proposed SSRD-CT because X-rays are restricted to irradiate a local smaller region. Taken together, the proposed SSRD-CT architecture will enable <= 50-ms temporal resolution and reduce radiation dose significantly.
引用
收藏
页码:1263 / 1271
页数:9
相关论文
共 37 条
[1]   Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience [J].
Achenbach, S ;
Ropers, D ;
Kuettner, A ;
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Theessen, H ;
Karakaya, M ;
Daniel, WG ;
Bautz, W ;
Kalender, WA ;
Anders, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :331-335
[2]   Prior Image Constrained Compressed Sensing (PICCS) and Applications in X-ray Computed Tomography [J].
Chen, Guang-Hong ;
Tang, Jie ;
Nett, Brian ;
Qi, Zhihua ;
Leng, Shuai ;
Szczykutowicz, Timothy .
CURRENT MEDICAL IMAGING, 2010, 6 (02) :119-134
[3]   Cardiac CT beyond coronary angiography: current and emerging non-coronary cardiac applications [J].
Desai, Milind Y. .
HEART, 2011, 97 (05) :417-424
[4]  
Douglas Pamela S, 2012, J Am Coll Cardiol, V59, P1833, DOI 10.1016/j.jacc.2012.01.005
[5]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[6]   Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality [J].
Flohr, Thomas G. ;
Leng, Shuai ;
Yu, Lifeng ;
Allmendinger, Thomas ;
Bruder, Herbert ;
Petersilka, Martin ;
Eusemann, Christian D. ;
Stierstorfer, Karl ;
Schmidt, Bernhard ;
McCollough, Cynthia H. .
MEDICAL PHYSICS, 2009, 36 (12) :5641-5653
[7]  
Flohr Thomas G, 2009, J Cardiovasc Comput Tomogr, V3, P143, DOI 10.1016/j.jcct.2009.04.004
[8]   High Power Distributed X-ray Source [J].
Frutschy, Kris ;
Neculaes, Bogdan ;
Inzinna, Lou ;
Caiafa, Antonio ;
Reynolds, Joe ;
Zou, Yun ;
Zhang, Xi ;
Gunturi, Satish ;
Cao, Yang ;
Waters, Bill ;
Wagner, Dave ;
De Man, Bruno ;
McDevitt, Dan ;
Roffers, Rick ;
Lounsberry, Brian ;
Pelc, Norbert J. .
MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
[9]   COMPUTERIZED TRANSVERSE AXIAL SCANNING (TOMOGRAPHY) .1. DESCRIPTION OF SYSTEM [J].
HOUNDFIELD, GN .
BRITISH JOURNAL OF RADIOLOGY, 1973, 46 (552) :1016-1022
[10]   Dual-source CT cardiac imaging: initial experience [J].
Johnson, Thorsten R. C. ;
Nikolaou, Konstantin ;
Wintersperger, Bernd J. ;
Leber, Alexander W. ;
von Ziegler, Franz ;
Rist, Carsten ;
Buhmann, Sonja ;
Knez, Andreas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2006, 16 (07) :1409-1415