Disinfection of secondary effluents using tin oxide anodes

被引:7
|
作者
Loge, FJ
Inouye, T
Watts, RJ
机构
[1] Univ Calif Davis, Dept Civil & Environm Engn, Davis, CA 95616 USA
[2] Washington State Univ, Dept Civil & Environm Engn, Pullman, WA 99164 USA
关键词
disinfection; tin oxide anodes; hydroxyl radicals; wastewater; emerging technologies;
D O I
10.2175/106143005X84503
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Direct current applied to a tin oxide anode submersed in water has the potential to generate hydroxyl radicals, a strong chemical oxidant. Tin oxide anode systems, which may represent a viable alternative disinfectant, were investigated for the disinfection of secondary effluents. Coliform bacteria in the effluent were effectively inactivated in a bench-scale tin oxide disinfection system. The number of anodes in the tin oxide disinfection system influenced the steady-state concentration of hydroxyl radicals and, consequently, the contact time necessary to achieve a specified dose. The life expectancy of the anodes was greater than 30 days and no appreciable loss of tin was observed over a 5-day period. A preliminary estimate of the capital and operating costs of a pilot- or full-scale tin oxide disinfection system designed to meet a discharge requirement of 23 most probable number/100 mL at a 3 785-m(3)/d (1-mgd) facility was comparable to UV and chlorination/dechlorination facilities. Based on this preliminary assessment, tin oxide disinfection systems are a promising alternative disinfectant for secondary effluents.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 50 条
  • [1] Disinfection of secondary effluents by infiltration-percolation
    Salgot, M
    Brissaud, F
    Campos, C
    WATER SCIENCE AND TECHNOLOGY, 1996, 33 (10-11) : 271 - 276
  • [2] Effect of Wastewater Quality Parameters on Oxidation by Tin Oxide Anodes
    Teel, Amy L.
    Finn, Dennis D.
    Watts, Richard J.
    WATER ENVIRONMENT RESEARCH, 2013, 85 (02) : 151 - 157
  • [3] Disinfection efficiency of secondary effluents with ultraviolet light in a Mediterranean area
    Bayo, J.
    Angosto, J. M.
    Ayala, P.
    WATER POLLUTION IX, 2008, 111 : 511 - 520
  • [4] Effect of wastewater quality parameters on coliform inactivation by tin oxide anodes
    Teel, Amy L.
    Watts, Richard J.
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2018, 53 (05): : 443 - 447
  • [5] Residence time distribution and disinfection of secondary effluents by infiltration percolation
    Brissaud, F
    Salgot, M
    Bancolé, A
    Campos, C
    Folch, M
    WATER SCIENCE AND TECHNOLOGY, 1999, 40 (4-5) : 215 - 222
  • [6] Disinfection of Digestate Effluents Using Photocatalytic Nanofiltration
    Chioti, Afroditi G.
    Sarikaki, Georgia
    Tsioni, Vasiliki
    Kostopoulou, Eleni
    Romanos, George Em.
    Falaras, Polycarpos
    Sfetsas, Themistoklis
    FERMENTATION-BASEL, 2023, 9 (07):
  • [7] Disinfection of municipal secondary effluents with microwave-induced electrodeless ultraviolet irradiation for water reuse
    Zhang, Yue
    Zhang, Guangshan
    Wang, Peng
    Wang, Qiao
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2017, 92 (05) : 1017 - 1025
  • [8] Performance Comparison of Tin Oxide Anodes to Commercially Available Dimensionally Stable Anodes
    Watts, Richard J.
    Finn, Dennis D.
    Wyeth, Megan S.
    Teel, Amy L.
    WATER ENVIRONMENT RESEARCH, 2008, 80 (06) : 490 - 496
  • [9] PERACETIC-ACID DISINFECTION OF SECONDARY EFFLUENTS DISCHARGED OFF COASTAL SEAWATER
    LEFEVRE, F
    AUDIC, JM
    FERRAND, F
    WATER SCIENCE AND TECHNOLOGY, 1992, 25 (12) : 155 - 164
  • [10] Phosphate Removal from Secondary Effluents Using Coal Gangue Loaded with Zirconium Oxide
    Xiong, Jibing
    Zang, Li
    Zha, Jianfeng
    Mahmood, Qaisar
    He, Zhenli
    SUSTAINABILITY, 2019, 11 (09)