Reverse Optic Capture of the Single-Piece Acrylic Intraocular Lens in Eyes With Posterior Capsule Rupture

被引:10
作者
Jones, Jason J. [1 ]
Oetting, Thomas A. [2 ]
Rogers, Gina M. [2 ]
Jin, George J. C. [1 ,3 ]
机构
[1] Jones Eye Clin & Surg Ctr, Sioux City, IA 51104 USA
[2] Univ Iowa, Dept Ophthalmol, Iowa City, IA 52242 USA
[3] Univ Utah, Dept Ophthalmol & Visual Sci, Salt Lake City, UT USA
关键词
SURGICAL-MANAGEMENT; SULCUS PLACEMENT; TERM OUTCOMES; IMPLANTATION; CATARACT; PHACOEMULSIFICATION; CHAMBER; CAPSULORHEXIS; ABSENCE; POWER;
D O I
10.3928/15428877-20120830-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To evaluate the clinical results of reverse optic capture (ROC) with single-piece posterior chamber intraocular lenses (PC-IOLs) in cases of phacoemulsification cataract and IOL surgery with posterior capsular rupture. PATIENTS AND METHODS: Preoperative diagnosis, intraoperative events, surgical parameters, intraoperative and postoperative complications, and preoperative and postoperative visual acuity and refraction of 16 eyes that underwent ROC were reviewed and analyzed. The fellow eye of 12 patients undergoing uneventful phacoemulsification without optic capture served as the control group. RESULTS: Over a mean of 19 months' follow-up, 94% of eyes in the ROC group and 92% in the control group achieved a best-corrected visual acuity of 20/25 or better. Ninety-four percent of eyes in the ROC group and 100% in the control group had postoperative spherical equivalent +/- 1.00 D of the intended refraction. Refraction was stable between 1 month and final follow-up in both groups. In all eyes with ROC, the IOL remained well centered with a securely captured optic. There were no vision-threatening complications throughout the follow-up. CONCLUSION: The comparable outcomes in both groups suggests that optic capture of a single-piece acrylic IOL through an anterior capsulorhexis merits consideration for IOL placement in selected cases of insufficient posterior capsule support. [Ophthalmic Surg Lasers Imaging 2012; 43: 480-488.]
引用
收藏
页码:480 / 488
页数:9
相关论文
共 50 条
[41]   Management of sulcus-fixated single-piece intraocular lens-induced pigmentary glaucoma with 3-piece IOL exchange [J].
Rabie, Hossein Mohammad ;
Esfandiari, Hamed ;
Rikhtegar, Mohammad Hassan ;
Hekmat, Vahid .
INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (01) :145-150
[42]   Intraocular lens optic edge design for the prevention of posterior capsule opacification after cataract surgery [J].
Maedel, Sophie ;
Evans, Jennifer R. ;
Harrer-Seely, Annette ;
Findl, Oliver .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2021, (08)
[43]   Intraindividual comparative analysis of capsule opacification after implantation of 2 single-piece hydrophobic acrylic intraocular lenses models: Three-year follow-up [J].
Kahraman, Guenal ;
Amon, Michael ;
Ferdinaro, Clara ;
Nigl, Karl ;
Walch, Michael .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (05) :990-996
[44]   Lens epithelial cell migration between posterior capsule and intraocular lens with variously finished posterior optic edge and two haptic angulations [J].
Ayaki, M ;
Ishida, Y ;
Nishimura, E ;
Yaguchi, S .
OPHTHALMIC RESEARCH, 2003, 35 (05) :261-267
[45]   Glued intraocular lens scaffolding to create an artificial posterior capsule for nucleus removal in eyes with posterior capsule tear and insufficient iris and sulcus support [J].
Agarwal, Amar ;
Jacob, Soosan ;
Agarwal, Ashvin ;
Narasimhan, Smita ;
Kumar, Dhivya Ashok ;
Agarwal, Athiya .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (03) :326-333
[46]   Visual Outcomes and Patient Satisfaction after Refractive Lens Exchange with a Single-Piece Diffractive Multifocal Intraocular Lens [J].
Chang, John S. M. ;
Ng, Jack C. M. ;
Chan, Vincent K. C. ;
Law, Antony K. P. .
JOURNAL OF OPHTHALMOLOGY, 2014, 2014
[47]   Ciliary sulcus implantation of intraocular lens in manual small incision cataract surgery complicated by large posterior capsule rupture [J].
Zhao, Jinrong ;
Yu, Jinguo ;
Wang, Tiecheng ;
Mban, Bertin .
EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2019, 17 (02) :1470-1475
[48]   Ocular aberrations and visual performance with an aspheric single-piece intraocular lens: Contralateral comparative study [J].
Assaf, Ahmed ;
Kotb, Ahmed .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (09) :1536-1542
[49]   Comparative Analysis of Residual Astigmatism Induced by a Single-piece or Three-piece Intraocular Lens after Cataract Surgery [J].
Chung, Jin Kwon ;
Kim, Mee Kum ;
Wee, Won Ryang .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
[50]   Influence of a Variable Overall Diameter Hydrophilic Acrylic Sharp-Edged Single-piece Intra-Ocular Lens on Capsule Opacification One Year after Surgery [J].
Mylonas, Georgios ;
Georgopoulos, Michael ;
Prinz, Ana ;
Vock, Lorenz ;
Blum, Robert A. ;
Schmidt-Erfurth, Ursula .
CURRENT EYE RESEARCH, 2014, 39 (06) :620-625