Reverse Optic Capture of the Single-Piece Acrylic Intraocular Lens in Eyes With Posterior Capsule Rupture

被引:10
作者
Jones, Jason J. [1 ]
Oetting, Thomas A. [2 ]
Rogers, Gina M. [2 ]
Jin, George J. C. [1 ,3 ]
机构
[1] Jones Eye Clin & Surg Ctr, Sioux City, IA 51104 USA
[2] Univ Iowa, Dept Ophthalmol, Iowa City, IA 52242 USA
[3] Univ Utah, Dept Ophthalmol & Visual Sci, Salt Lake City, UT USA
关键词
SURGICAL-MANAGEMENT; SULCUS PLACEMENT; TERM OUTCOMES; IMPLANTATION; CATARACT; PHACOEMULSIFICATION; CHAMBER; CAPSULORHEXIS; ABSENCE; POWER;
D O I
10.3928/15428877-20120830-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To evaluate the clinical results of reverse optic capture (ROC) with single-piece posterior chamber intraocular lenses (PC-IOLs) in cases of phacoemulsification cataract and IOL surgery with posterior capsular rupture. PATIENTS AND METHODS: Preoperative diagnosis, intraoperative events, surgical parameters, intraoperative and postoperative complications, and preoperative and postoperative visual acuity and refraction of 16 eyes that underwent ROC were reviewed and analyzed. The fellow eye of 12 patients undergoing uneventful phacoemulsification without optic capture served as the control group. RESULTS: Over a mean of 19 months' follow-up, 94% of eyes in the ROC group and 92% in the control group achieved a best-corrected visual acuity of 20/25 or better. Ninety-four percent of eyes in the ROC group and 100% in the control group had postoperative spherical equivalent +/- 1.00 D of the intended refraction. Refraction was stable between 1 month and final follow-up in both groups. In all eyes with ROC, the IOL remained well centered with a securely captured optic. There were no vision-threatening complications throughout the follow-up. CONCLUSION: The comparable outcomes in both groups suggests that optic capture of a single-piece acrylic IOL through an anterior capsulorhexis merits consideration for IOL placement in selected cases of insufficient posterior capsule support. [Ophthalmic Surg Lasers Imaging 2012; 43: 480-488.]
引用
收藏
页码:480 / 488
页数:9
相关论文
共 50 条
[11]   Prospective evaluation of posterior capsule opacification in myopic eyes 4 years after implantation of a single-piece acrylic IOL [J].
Vasavada, Abhay R. ;
Shah, Alpesh ;
Raj, Shetal M. ;
Praveen, Mamidipudi R. ;
Shah, Gauri D. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (09) :1532-1539
[12]   Early Clinical Experience with a New Hydrophobic Acrylic Single-Piece Monofocal Intraocular Lens [J].
Schallhorn, Steven C. ;
Teenan, David ;
Venter, Jan A. ;
Schallhorn, Julie M. ;
Hannan, Stephen J. .
CLINICAL OPHTHALMOLOGY, 2023, 17 :3419-3427
[13]   Scleral fixation of a single-piece multifocal intraocular lens [J].
Can, Ertugrul ;
Basaran, M. Resat ;
Gul, Adem .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (02) :249-251
[14]   LONG-TERM STABILITY AND VISUAL OUTCOMES OF A SINGLE-PIECE, FOLDABLE, ACRYLIC INTRAOCULAR LENS FOR SCLERAL FIXATION [J].
Kim, Stephen Jae ;
Lee, Sung Jin ;
Park, Chang Hyun ;
Jung, Gi Yong ;
Park, Song Hee .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (01) :91-97
[15]   Posterior optic capture for repositioning of dislocated three-piece intraocular lens: a single center retrospective study [J].
Asano, Yasuhiko ;
Onda, Hidetoshi .
BMC OPHTHALMOLOGY, 2025, 25 (01)
[16]   Retrospective ultrasound biomicroscopic analysis of single-piece sulcus-fixated acrylic intraocular lenses [J].
Vasavada, Abhay R. ;
Raj, Shetal M. ;
Karve, Shrihari ;
Vasavada, Viraj ;
Vasavada, Vaishali ;
Theoulakis, Panagiotis .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (05) :771-777
[17]   Evaluation of a new single-piece 4% water content hydrophobic acrylic intraocular lens in the rabbit model [J].
Ollerton, Andrew ;
Werner, Liliana ;
Fuller, Stanley R. ;
Kavoussi, Shaheen C. ;
McIntyre, J. Steele ;
Mamalis, Nick .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (10) :1827-1832
[18]   Early Postoperative Rotational stability and its related factors of a single-piece acrylic toric intraocular lens [J].
Li, Shuyi ;
Li, Xi ;
He, Suhong ;
Zheng, Qianyin ;
Chen, Xiang ;
Wu, Xingdi ;
Xu, Wen .
EYE, 2020, 34 (03) :474-479
[19]   True rotational stability of a single-piece hydrophobic intraocular lens [J].
Schartmueller, Daniel ;
Schriefl, Sabine ;
Schwarzenbacher, Luca ;
Leydolt, Christina ;
Menapace, Rupert .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2019, 103 (02) :186-190
[20]   Clinicopathologic correlation of capsulorhexis phimosis with anterior flexing of single-piece hydrophilic acrylic intraocular lens haptics [J].
Zaugg, Brian ;
Werner, Liliana ;
Neuhann, Tobias ;
Burrow, Michael ;
Davis, Don ;
Mamalis, Nick ;
Tetz, Manfred .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (09) :1605-1609