Effect of contact lens surface properties on comfort, tear stability and ocular physiology

被引:57
|
作者
Vidal-Rohr, Maria [1 ,2 ]
Wolffsohn, James S. [1 ]
Davies, Leon N. [1 ]
Cervino, Alejandro [2 ]
机构
[1] Aston Univ, Ophthalm Res Grp, Birmingham B4 7ET, W Midlands, England
[2] Univ Valencia, Dept Opt & Optometry & Vis Sci, Optometry Res Grp, E-46100 Burjassot, Spain
基金
英国工程与自然科学研究理事会;
关键词
Discomfort; Coating; Soft contact lens; Tear film; Lubricity; Coefficient of friction; TFOS INTERNATIONAL WORKSHOP; DRY EYE DISEASE; CLINICAL-EVALUATION; DISCOMFORT REPORT; NORTH-AMERICA; WEARERS; FILM; SYMPTOMS; SUBCOMMITTEE;
D O I
10.1016/j.clae.2017.09.009
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: Retrospective analysis of different contact lens wearing groups suggests lens surface lubricity is the main factor influencing contact lens comfort. However, the examined commercially available contact lenses differ in material and design as well as surface properties. Hence this study isolates the contribution of lens surface properties using an ultra-thin coating technology. Methods: Nineteen habitual contact lens wearers (21.6 +/- 1.7 years) wore formofilcon B soft monthly disposable contact lenses with and without coating technology modified surface properties for a month each in a randomised double-masked cross-over study. Objective non-invasive: breakup time (NIKBUT), NIKBUT average and ocular redness (Jenvis grading scale) were evaluated (Keratograph 5M) after 1 week and 1 month of wear. Symptoms were assessed using the Contact Lens Dry Eye Questionnaire (CLDEQ-8); perceived vision quality and subjective lens comfort at insertion, mid-day and end of the day were rated with four Visual Analog Scales. Results: Perceived visual quality (F = 5.049, p = 0.037), contact lens dry eye symptoms (F = 14.408, p = 0.001) and subjective lens comfort (F = 28.447, p < 0.001) were better for coated compared to uncoated lenses. The surface coating postponed the lens dewetting (F = 8.518, p = 0.009) and increased the pre-lens tear film stability (F = 5.626, p = 0.029), but bulbar (F = 0.340, p = 0.567) and limbal (F = 0.110, p = 0.744) redness were similar for both contact lenses. No parameter changed significantly between a weeks' and months' wear (p > 0.05). Lens surface wettability and ocular redness were not correlated to changes in symptoms (p > 0.05). Conclusion: As previously hypothesised, enhancing the physical surface properties of a soft contact lens improves subjectively rated wearer comfort, which, in turn, should result in reduced contact lens discontinuation.
引用
收藏
页码:117 / 121
页数:5
相关论文
共 50 条
  • [1] Daily versus monthly disposable contact lens: Which is better for ocular surface physiology and comfort?
    Sapkota, Kishor
    Franco, Sandra
    Lira, Madalena
    CONTACT LENS & ANTERIOR EYE, 2018, 41 (03) : 252 - 257
  • [2] Improving ocular surface comfort in contact lens wearers
    Fernandez-Jimenez, Elena
    Diz-Arias, Elena
    Peral, Assumpta
    CONTACT LENS & ANTERIOR EYE, 2022, 45 (03)
  • [3] Influence of Tear Film and Contact Lens Osmolality on Ocular Comfort in Contact Lens Wear
    Stahl, Ulrike
    Willcox, Mark D. P.
    Naduvilath, Thomas
    Stapleton, Fiona
    OPTOMETRY AND VISION SCIENCE, 2009, 86 (07) : 857 - 867
  • [4] Tear Lipid Layer and Contact Lens Comfort: A Review
    Rohit, Athira
    Willcox, Mark
    Stapleton, Fiona
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (03): : 247 - 253
  • [5] Effect of contact lens materials on tear physiology
    Thai, LC
    Tomlinson, A
    Doane, MG
    OPTOMETRY AND VISION SCIENCE, 2004, 81 (03) : 194 - 204
  • [6] Effect of Short Recovery Periods on Ocular Comfort During Daily Lens Wear
    Stahl, Ulrike
    Keir, Nancy J.
    Landers, Alan
    Jones, Lyndon W.
    OPTOMETRY AND VISION SCIENCE, 2016, 93 (08) : 861 - 871
  • [7] Conjunctival Vascular Adaptation Related to Ocular Comfort in Habitual Contact Lens Wearers
    Chen, Qi
    Jiang, Hong
    Wang, Jianhua
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 216 : 99 - 109
  • [8] The ability of the Contact Lens Dry Eye Questionnaire (CLDEQ)-8 to detect ocular surface alterations in contact lens wearers
    Lopez-de la Rosa, Alberto
    Arroyo-del Arroyo, Cristina
    Enriquez-de-Salamanca, Amalia
    Pinto-Fraga, Jose
    Lopez-Miguel, Alberto
    Gonzalez-Garcia, Maria J.
    CONTACT LENS & ANTERIOR EYE, 2019, 42 (03) : 273 - 277
  • [9] The influence of protein deposition on contact lens tear film stability
    Rabiah, Noelle I.
    Scales, Charles W.
    Fuller, Gerald G.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2019, 180 : 229 - 236
  • [10] The Impact of Contact Lens Wear and Visual Display Terminal Work on Ocular Surface and Tear Functions in Office Workers
    Kojima, Takashi
    Ibrahim, Osama M. A.
    Wakamatsu, Tais
    Tsuyama, Atsushi
    Ogawa, Junko
    Matsumoto, Yukihiro
    Dogru, Murat
    Tsubota, Kazuo
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 152 (06) : 933 - 940